메뉴 건너뛰기




Volumn 1, Issue 7, 2002, Pages 406-

Refined analysis of transcranial Doppler HITS [3]

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFACT; AUTOMATION; BRAIN BLOOD FLOW; DIAGNOSTIC ACCURACY; DISEASE CLASSIFICATION; DOPPLER ECHOGRAPHY; HIGH RISK PATIENT; HUMAN; LETTER; MEASUREMENT; MICROEMBOLISM; MIDDLE CEREBRAL ARTERY; MONITORING; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RECORDING; SIGNAL PROCESSING; BRAIN ARTERY; BRAIN CIRCULATION; BRAIN EMBOLISM; CEREBROVASCULAR ACCIDENT; ECHOGRAPHY; EPIDEMIOLOGY; METHODOLOGY; PATHOPHYSIOLOGY; PATIENT SELECTION; PHYSIOLOGY; PREDICTION AND FORECASTING; REVIEW; RISK FACTOR;

EID: 0041349311     PISSN: 14744422     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1474-4422(02)00216-8     Document Type: Letter
Times cited : (4)

References (6)
  • 1
    • 0022625812 scopus 로고
    • Monitoring middle cerebral artery blood velocity during carotid endarterectomy
    • Padayachee T.S., Gosling R.G., Bishop C.C., Burnand K., Browse N.L. Monitoring middle cerebral artery blood velocity during carotid endarterectomy. Br J Surg. 73:1986;98-100.
    • (1986) Br J Surg , vol.73 , pp. 98-100
    • Padayachee, T.S.1    Gosling, R.G.2    Bishop, C.C.3    Burnand, K.4    Browse, N.L.5
  • 2
    • 0141745590 scopus 로고    scopus 로고
    • Transcranial Doppler monitoring during carotid endarterectomy
    • M. Hennerici, & S. Meairs. Cambridge: Cambridge University Press
    • Naylor A.R. Transcranial Doppler monitoring during carotid endarterectomy. Hennerici M., Meairs S. Cerebrovascular Ultrasound - theory, practice and future developments. 2001;317-323 Cambridge University Press, Cambridge.
    • (2001) Cerebrovascular Ultrasound - theory, practice and future developments , pp. 317-323
    • Naylor, A.R.1
  • 3
    • 0036330322 scopus 로고    scopus 로고
    • Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler
    • Russell D., Brucher R. Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler. Stroke. 33:2002;1975-1980.
    • (2002) Stroke , vol.33 , pp. 1975-1980
    • Russell, D.1    Brucher, R.2
  • 4
    • 0036327315 scopus 로고    scopus 로고
    • Automatic online embolus detection and artifact rejection with the first multifrequency transcranial Doppler
    • Brucher R., Russell D. Automatic online embolus detection and artifact rejection with the first multifrequency transcranial Doppler. Stroke. 33:2002;1969-1974.
    • (2002) Stroke , vol.33 , pp. 1969-1974
    • Brucher, R.1    Russell, D.2
  • 5
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
    • Wei K., Jayaweera A.R., Firoozan S., Linka A., Skyba D.M., Kaul S. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation. 97:1998;473-483.
    • (1998) Circulation , vol.97 , pp. 473-483
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3    Linka, A.4    Skyba, D.M.5    Kaul, S.6
  • 6
    • 0034639663 scopus 로고    scopus 로고
    • Pulse-inversion contrast harmonic imaging: Ultrasonographic assessment of cerebral perfusion
    • Meairs S., Daffertshofer M., Neff W., Eschenfelder C., Hennerici M. Pulse-inversion contrast harmonic imaging: ultrasonographic assessment of cerebral perfusion. Lancet. 355:2000;550-551.
    • (2000) Lancet , vol.355 , pp. 550-551
    • Meairs, S.1    Daffertshofer, M.2    Neff, W.3    Eschenfelder, C.4    Hennerici, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.