메뉴 건너뛰기




Volumn 794, Issue 2, 2003, Pages 329-335

Determination of tobramycin in serum using liquid chromatography-tandem mass spectrometry and comparison with a fluorescence polarisation assay

Author keywords

Tobramycin

Indexed keywords

ACETONITRILE; BIOASSAY; FLUORESCENCE; LIQUID CHROMATOGRAPHY; MASS SPECTROMETRY; METHANOL; PRECIPITATION (CHEMICAL); PROTEINS;

EID: 0041328031     PISSN: 15700232     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1570-0232(03)00492-6     Document Type: Article
Times cited : (60)

References (16)
  • 1
    • 0017106637 scopus 로고
    • Ototoxicity of tobramycin; A clinical review
    • Neu H.C., Dendush C.L. Ototoxicity of tobramycin; a clinical review. J. Infect. Dis. 134:1976;S206.
    • (1976) J. Infect. Dis. , vol.134 , pp. 206
    • Neu, H.C.1    Dendush, C.L.2
  • 2
    • 0018638848 scopus 로고
    • Aminoglycoside nephrotoxicity: Comparative assessment in critically ill
    • Plaut N.E., Schentag J.J., Jusko W.J. Aminoglycoside nephrotoxicity: comparative assessment in critically ill. J. Med. 10:1979;257.
    • (1979) J. Med. , vol.10 , pp. 257
    • Plaut, N.E.1    Schentag, J.J.2    Jusko, W.J.3
  • 3
    • 0018883872 scopus 로고
    • Double blind comparison of the nephrotoxicity and auditory toxicity of gentamicin and tobramycin
    • Smith C.R., Lipsky J.J., Laskin O.L., Hellman D.B., et al. Double blind comparison of the nephrotoxicity and auditory toxicity of gentamicin and tobramycin. New Eng. J. Med. 302:1980;1106.
    • (1980) New Eng. J. Med. , vol.302 , pp. 1106
    • Smith, C.R.1    Lipsky, J.J.2    Laskin, O.L.3    Hellman, D.B.4
  • 5
    • 0018100071 scopus 로고
    • Monitoring aminoglycoside use in patients with severely impaired renal function
    • Noone P., Beale D.F., Pollock S.S., et al. Monitoring aminoglycoside use in patients with severely impaired renal function. Br. Med. J. 2:1978;4670.
    • (1978) Br. Med. J. , vol.2 , pp. 4670
    • Noone, P.1    Beale, D.F.2    Pollock, S.S.3
  • 6
    • 0018311647 scopus 로고
    • Determination of aminoglycoside antibiotics in biological fluids
    • Maitra S.K., Yoshikawa T.T., Guze L.B., et al. Determination of aminoglycoside antibiotics in biological fluids. Clin. Chem. 25:1979;1361.
    • (1979) Clin. Chem. , vol.25 , pp. 1361
    • Maitra, S.K.1    Yoshikawa, T.T.2    Guze, L.B.3
  • 7
    • 0344923822 scopus 로고    scopus 로고
    • Aminoglycoside antibiotics, two decades of their HPLC bioanalysis
    • Soltes L. Aminoglycoside antibiotics, two decades of their HPLC bioanalysis. Biomed. Chromatogr. 13:1999;3.
    • (1999) Biomed. Chromatogr. , vol.13 , pp. 3
    • Soltes, L.1
  • 8
    • 85031081762 scopus 로고    scopus 로고
    • Department of Microbiology, Southmead Hospital, Bristol
    • UKNEQAS for Antibiotic Assays. Department of Microbiology, Southmead Hospital, Bristol.
    • UKNEQAS for Antibiotic Assays
  • 9
    • 0026786428 scopus 로고
    • Enhancement of detector sensitivity and cleanup selectivity for tobramycin through precolumn derivatization
    • Lai F., Sheehan T. Enhancement of detector sensitivity and cleanup selectivity for tobramycin through precolumn derivatization. J. Chromatogr. 18:1992;173.
    • (1992) J. Chromatogr. , vol.18 , pp. 173
    • Lai, F.1    Sheehan, T.2
  • 10
    • 0025261419 scopus 로고
    • Determination of tobramycin using high-performance liquid chromatography with pulsed amperometric detection
    • Statler J.A. Determination of tobramycin using high-performance liquid chromatography with pulsed amperometric detection. J. Chromatogr. 27:1990;244.
    • (1990) J. Chromatogr. , vol.27 , pp. 244
    • Statler, J.A.1
  • 11
    • 0037175421 scopus 로고    scopus 로고
    • Trace analysis of tobramycin in human plasma by derivatisation and high-performance liquid chromatography with ultraviolet detection
    • Feng C.H., Lin S.J., Wu H.L., Chen S.H. Trace analysis of tobramycin in human plasma by derivatisation and high-performance liquid chromatography with ultraviolet detection. J. Chromatogr. B. 780:2002;349.
    • (2002) J. Chromatogr. B , vol.780 , pp. 349
    • Feng, C.H.1    Lin, S.J.2    Wu, H.L.3    Chen, S.H.4
  • 12
    • 0034083740 scopus 로고    scopus 로고
    • Determination of gentamicins C1, C1a and C2 in plasma and urine by HPLC
    • Isoheranen N., Soback S. Determination of gentamicins C1, C1a and C2 in plasma and urine by HPLC. Clin. Chem. 46:2000;837.
    • (2000) Clin. Chem. , vol.46 , pp. 837
    • Isoheranen, N.1    Soback, S.2
  • 13
    • 0031469239 scopus 로고    scopus 로고
    • Effect of variability of plasma interferences on the accuracy of drug immunoassays
    • Ezan E., Emmanuel A., Valente D., Grognet J.-M. Effect of variability of plasma interferences on the accuracy of drug immunoassays. Ther. Drug Monit. 19:1997;212.
    • (1997) Ther. Drug Monit. , vol.19 , pp. 212
    • Ezan, E.1    Emmanuel, A.2    Valente, D.3    Grognet, J.-M.4
  • 14
    • 0033957479 scopus 로고    scopus 로고
    • Confirmation of gentamicin and neomycin in milk by weak cation-exchange extraction and electrospray ionization/ion trap tandem mass spectrometry
    • Heller D.N., Clark S.B., Righter H.F. Confirmation of gentamicin and neomycin in milk by weak cation-exchange extraction and electrospray ionization/ion trap tandem mass spectrometry. J. Mass. Spectrom. 35:2000;39.
    • (2000) J. Mass. Spectrom. , vol.35 , pp. 39
    • Heller, D.N.1    Clark, S.B.2    Righter, H.F.3
  • 15
    • 0033661809 scopus 로고    scopus 로고
    • Determination of gentamicin in swine and calf tissues by high-performance liquid chromatography combined with electrospray ionization mass spectrometry
    • Cherlet M., De Baere S., De Backer P. Determination of gentamicin in swine and calf tissues by high-performance liquid chromatography combined with electrospray ionization mass spectrometry. J. Mass. Spectrom. 35:2000;1342.
    • (2000) J. Mass. Spectrom. , vol.35 , pp. 1342
    • Cherlet, M.1    De Baere, S.2    De Backer, P.3
  • 16
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1:1986;307.
    • (1986) Lancet , vol.1 , pp. 307
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.