Novel approach to the Rayleigh-to-Compton method: Wavelength dispersive tomography

Author keywords

Coherent scattering; Non destructive material testing; Rayleigh to Compton method; Tomography; X ray instrumentation

Indexed keywords

ATOMIC SPECTROSCOPY; ATOMS; COMPTON SCATTERING; COMPUTATIONAL GEOMETRY; COMPUTERIZED TOMOGRAPHY; DETECTORS; DIAGNOSTIC RADIOGRAPHY; ELECTRIC INSTRUMENT TRANSFORMERS; GEOMETRY; IMAGING SYSTEMS; INSTRUMENTS; LIGHT EMISSION; LIGHT SCATTERING; LUMINESCENCE; MATERIALS; MESH GENERATION; MULTIPHOTON PROCESSES; NEUTRON DETECTORS; SCATTERING; SCINTILLATION; SCINTILLATION COUNTERS; TOMOGRAPHY;

EID: 0040418153     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.292720     Document Type: Conference Paper
Times cited : (3)

References (16)
  • 2
    • 0028807076 scopus 로고
    • A k edge filter technique for optimization of the coherent-to-compton scatter ratio method
    • G. Harding, R. Armstrong, S. McDaid, and M. Cooper, "A k edge filter technique for optimization of the coherent-to-compton scatter ratio method," Med. Phys. 22(12), p. 2007, 1995.
    • (1995) Med. Phys , vol.22 , Issue.12 , pp. 2007
    • Harding, G.1    Armstrong, R.2    McDaid, S.3    Cooper, M.4
  • 3
    • 0017068655 scopus 로고
    • A new photon scattering method for bone mineral density measurements
    • P. Puumalainen, A. Uimarihuhta, E. A. Alhva, and H. Olkkonen, "A new photon scattering method for bone mineral density measurements," Radiology 120, p. 723, 1976.
    • (1976) Radiology , vol.120 , pp. 723
    • Puumalainen, P.1    Uimarihuhta, A.2    Alhva, E.A.3    Olkkonen, H.4
  • 4
    • 0021356350 scopus 로고
    • The effect of the momentum transfer on the sensitivity of a photon scattering method for the characterization of tissues
    • I. Leichter, A. Karellas, J. D. Craven, and M. A. Greenfield, "The effect of the momentum transfer on the sensitivity of a photon scattering method for the characterization of tissues," Med. Phys. 11(1), 1984.
    • (1984) Med. Phys , vol.11 , Issue.1
    • Leichter, I.1    Karellas, A.2    Craven, J.D.3    Greenfield, M.A.4
  • 5
    • 0021880775 scopus 로고
    • Quantitative assessment of bone mineral by photon scattering: Accuracy and precision considerations
    • S. S. Shukla, A. Karellas, I. Leichter, J. D. Craven, and M. A. Greenfield, "Quantitative assessment of bone mineral by photon scattering: Accuracy and precision considerations," Med. Phys. 12(4), p. 447, 1985.
    • (1985) Med. Phys , vol.12 , Issue.4 , pp. 447
    • Shukla, S.S.1    Karellas, A.2    Leichter, I.3    Craven, J.D.4    Greenfield, M.A.5
  • 6
    • 0020629327 scopus 로고
    • Characterization of tissue via coherent-to-compton scattering ratio: Sensitivity considerations
    • A. Karellas, I. Leichter, J. D. Craven, and M. A. Greenfield, "Characterization of tissue via coherent-to-compton scattering ratio: Sensitivity considerations," Med. Phys. 10(5), p. 605, 1983.
    • (1983) Med. Phys , vol.10 , Issue.5 , pp. 605
    • Karellas, A.1    Leichter, I.2    Craven, J.D.3    Greenfield, M.A.4
  • 7
    • 0026049510 scopus 로고
    • Coherent scattering and bone mineral measurement: The dependence of sensitivity on angle and energy
    • A. M. Ndlovu, T. J. Farrell, and C. E. Webber, "Coherent scattering and bone mineral measurement: The dependence of sensitivity on angle and energy," Med. Phys. 18(5), p. 985, 1991.
    • (1991) Med. Phys , vol.18 , Issue.5 , pp. 985
    • Ndlovu, A.M.1    Farrell, T.J.2    Webber, C.E.3
  • 8
    • 0021881158 scopus 로고
    • A large-angle coherent/compton scattering method for measurement in vitro of trabecular bone mineral concentration
    • G. E. Gigante and S. Sciuti, "A large-angle coherent/compton scattering method for measurement in vitro of trabecular bone mineral concentration," Med. Phys. 12(3), p. 321, 1985.
    • (1985) Med. Phys , vol.12 , Issue.3 , pp. 321
    • Gigante, G.E.1    Sciuti, S.2
  • 9
    • 58749083357 scopus 로고    scopus 로고
    • Rayleigh-to-compton tomography with a bent laue analyzer crystal
    • to be published
    • C. Schulze and U. Kleuker, "Rayleigh-to-compton tomography with a bent laue analyzer crystal." J. of Synchr. Rad. (SRI97 proceedings), 1997. to be published.
    • (1997) J. of Synchr. Rad. (SRI97 proceedings)
    • Schulze, C.1    Kleuker, U.2
  • 10
    • 0029244544 scopus 로고
    • Pepo: A program for the calculation of the reflectivity of cylindrically bent laue monochromators
    • C. Schulze and D. Chapman, "Pepo: A program for the calculation of the reflectivity of cylindrically bent laue monochromators," Rev. Sci. Instrum. 66(2), p. 2220, 1995.
    • (1995) Rev. Sci. Instrum , vol.66 , Issue.2 , pp. 2220
    • Schulze, C.1    Chapman, D.2
  • 13
    • 0028534844 scopus 로고
    • Analytical cross sections for monte carlo simulation of photon transport
    • J. Baró, M. Roteta, J. M. Fernández-Varea, and F. Salvat, "Analytical cross sections for monte carlo simulation of photon transport," Radiat. Phys. Chem. 44(5), p. 531, 1994.
    • (1994) Radiat. Phys. Chem , vol.44 , Issue.5 , pp. 531
    • Baró, J.1    Roteta, M.2    Fernández-Varea, J.M.3    Salvat, F.4
  • 14
    • 0021383656 scopus 로고    scopus 로고
    • S. Manninen, T. Pitkacombining double acute accentnen, S. Koikkalainen, and T. Paakkari, Study of the ratio of elastic to inelastic scattering of photons, Int. J. Appl. Radiat. Isot. 35(2), p. 93, 1984.
    • S. Manninen, T. Pitkacombining double acute accentnen, S. Koikkalainen, and T. Paakkari, "Study of the ratio of elastic to inelastic scattering of photons," Int. J. Appl. Radiat. Isot. 35(2), p. 93, 1984.
  • 15
    • 58749098934 scopus 로고    scopus 로고
    • X-ray computed diffraction tomography: A survey and description
    • U. Kleuker, "X-ray computed diffraction tomography: A survey and description." in this proceeding volume, 1997.
    • this proceeding , vol.1997
    • Kleuker, U.1
  • 16
    • 0017456809 scopus 로고
    • Reconstruction of objects from their projections. the influence of measurement errors on the reconstruction
    • G. Kowalski, "Reconstruction of objects from their projections. the influence of measurement errors on the reconstruction," IEEE Trans. Nucl. Sc. NS-24(1), p. 850, 1977.
    • (1977) IEEE Trans. Nucl. Sc , vol.NS-24 , Issue.1 , pp. 850
    • Kowalski, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.