메뉴 건너뛰기




Volumn 113, Issue 6, 2000, Pages 493-497

Relationship between isometric exercise and myocardial ischemia in patients with coronary artery disease : An Echo-Doppler study

Author keywords

Cardiac rehabilitation; Echo Doppler; Isometric exercise; Left ventricular function; Myocardial ischemia

Indexed keywords

AGED; ARTICLE; DOPPLER ECHOCARDIOGRAPHY; ECHOGRAPHY; EXERCISE; FEMALE; HEART; HEART MUSCLE ISCHEMIA; HUMAN; MALE; MIDDLE AGED; OXYGEN CONSUMPTION; PATHOPHYSIOLOGY;

EID: 0039925482     PISSN: 03666999     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (8)
  • 1
    • 0023218313 scopus 로고
    • The cardiovascular response to circuit weight training in patients with cardiac disease
    • Bulter RM, Beierwaltes WH, Rodgers FJ, et al. The cardiovascular response to circuit weight training in patients with cardiac disease. J Cardiopulmon Rehab 1987;7:402-409.
    • (1987) J Cardiopulmon Rehab , vol.7 , pp. 402-409
    • Bulter, R.M.1    Beierwaltes, W.H.2    Rodgers, F.J.3
  • 2
    • 0041145571 scopus 로고
    • Graded isometric exercise on mitral valve blood flow in normal subjects and patients with post myocardial infarction
    • Li J. Graded isometric exercise on mitral valve blood flow in normal subjects and patients with post myocardial infarction. Chin J Rehab Med 1993;8:244-251.
    • (1993) Chin J Rehab Med , vol.8 , pp. 244-251
    • Li, J.1
  • 3
    • 0039958485 scopus 로고
    • Mechanism of pulmonary wedge pressure elevation during isometric exercise in patients with coronary artery disease
    • Li J. Mechanism of pulmonary wedge pressure elevation during isometric exercise in patients with coronary artery disease. Chin J Rehab Med 1993;8:1-7.
    • (1993) Chin J Rehab Med , vol.8 , pp. 1-7
    • Li, J.1
  • 4
    • 0030809059 scopus 로고    scopus 로고
    • Left ventricular diastolic filling dynamics during isometric exertion in syndrome X assessed with Doppler flowmetry
    • Mizushige K, Masugata H, Morita H, et al. Left ventricular diastolic filling dynamics during isometric exertion in syndrome X assessed with Doppler flowmetry. Angiology 1997;48:871-881.
    • (1997) Angiology , vol.48 , pp. 871-881
    • Mizushige, K.1    Masugata, H.2    Morita, H.3
  • 6
    • 0030034431 scopus 로고    scopus 로고
    • Differential responses in left ventricular diastolic filling dynamics with isometric handgrip versus isotonic treadmill exertion
    • Mizushige K, Matsuo H, Nozaki S, et al. Differential responses in left ventricular diastolic filling dynamics with isometric handgrip versus isotonic treadmill exertion. Am Heart J 1996;131:131-137.
    • (1996) Am Heart J , vol.131 , pp. 131-137
    • Mizushige, K.1    Matsuo, H.2    Nozaki, S.3
  • 7
    • 0031567855 scopus 로고    scopus 로고
    • Measurement of coronary blood flow velocity during handgrip exercise using breath-hold velocity encoded cine magnetic resonance imaging
    • Globits S, Sakuma H, Shimakawa A, et al. Measurement of coronary blood flow velocity during handgrip exercise using breath-hold velocity encoded cine magnetic resonance imaging. Am J Cardiol 1997; 79:234-237.
    • (1997) Am J Cardiol , vol.79 , pp. 234-237
    • Globits, S.1    Sakuma, H.2    Shimakawa, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.