-
1
-
-
0025665196
-
Lung damage from exposure to pulsed ultrasound
-
S. Z. Child, C. L. Hartman, L. A. Schery, and E. L. Carstensen, "Lung damage from exposure to pulsed ultrasound," Ultrasound Med. Biol. 16, 817-825 (1990).
-
(1990)
Ultrasound Med. Biol.
, vol.16
, pp. 817-825
-
-
Child, S.Z.1
Hartman, C.L.2
Schery, L.A.3
Carstensen, E.L.4
-
2
-
-
0025002249
-
Lung damage from exposure to the fields of an electrohydraulic lithotripter
-
C. L. Hartman, S. Z. Child, R. Mayer, E. Schenk, and E. L. Carstensen, "Lung damage from exposure to the fields of an electrohydraulic lithotripter," Ultrasound Med. Biol. 16, 675-683 (1990).
-
(1990)
Ultrasound Med. Biol.
, vol.16
, pp. 675-683
-
-
Hartman, C.L.1
Child, S.Z.2
Mayer, R.3
Schenk, E.4
Carstensen, E.L.5
-
3
-
-
0028347174
-
Effects of pulsed ultrasound on the mouse neonate: Hind limb paralysis and lung hemorrhage
-
L. A. Frizzell, E. Chen, and C. Lee, "Effects of pulsed ultrasound on the mouse neonate: Hind limb paralysis and lung hemorrhage," Ultrasound Med. Biol. 20, 53-63 (1994).
-
(1994)
Ultrasound Med. Biol.
, vol.20
, pp. 53-63
-
-
Frizzell, L.A.1
Chen, E.2
Lee, C.3
-
4
-
-
0029192224
-
Lung hemorrhage induced by continuous and pulse wave ultrasound in mice, rabbits, and pigs
-
J. F. Zachary and W. D. O'Brien, Jr., "Lung hemorrhage induced by continuous and pulse wave ultrasound in mice, rabbits, and pigs," Vet. Pathol. 32, 43-54 (1995).
-
(1995)
Vet. Pathol.
, vol.32
, pp. 43-54
-
-
Zachary, J.F.1
O'Brien Jr., W.D.2
-
5
-
-
0031100643
-
Lung damage assessment from exposure to pulsed-wave ultrasound in rabbit, mouse, and pig
-
W. D. O'Brien, Jr. and J. F. Zachary, "Lung damage assessment from exposure to pulsed-wave ultrasound in rabbit, mouse, and pig," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 44, 473-485 (1997).
-
(1997)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.44
, pp. 473-485
-
-
O'Brien Jr., W.D.1
Zachary, J.F.2
-
6
-
-
0029741912
-
Direct evidence of cavitation in vivo from diagnostic ultrasound
-
C. K. Holland, C. X. Deng, R. E. Apfel, J. L. Alderman, L. A. Fernandez, and K. J. Taylor, "Direct evidence of cavitation in vivo from diagnostic ultrasound" Ultrasound Med. Biol. 22, 917-925 (1996).
-
(1996)
Ultrasound Med. Biol.
, vol.22
, pp. 917-925
-
-
Holland, C.K.1
Deng, C.X.2
Apfel, R.E.3
Alderman, J.L.4
Fernandez, L.A.5
Taylor, K.J.6
-
7
-
-
0028214968
-
Ultrasound-Induced lung hemorrhage in the monkey
-
A. F. Tarantal and D. R. Cantield, "Ultrasound-Induced lung hemorrhage in the monkey," Ultrasound Med. Biol. 20, 65-72 (1994).
-
(1994)
Ultrasound Med. Biol.
, vol.20
, pp. 65-72
-
-
Tarantal, A.F.1
Cantield, D.R.2
-
8
-
-
0029165917
-
Microscopic lung alterations and reduction of respiration rate in insonated anesthetized swing
-
G. H. Harrison, H. A. Eddy, J.-P. Wang, and F. Z. Liberman, "Microscopic lung alterations and reduction of respiration rate in insonated anesthetized swing," Ultrasound Med. Biol. 21, 981-983 (1995).
-
(1995)
Ultrasound Med. Biol.
, vol.21
, pp. 981-983
-
-
Harrison, G.H.1
Eddy, H.A.2
Wang, J.-P.3
Liberman, F.Z.4
-
9
-
-
0030058320
-
Thresholds for ultrasonically induced lung hemorrhage in neonatal swine
-
R. Baggs, D. P. Penney, C. Cox, S. Z. Child, C. H. Raeman, D. Dalecki, and E. L. Carstensen, "Thresholds for ultrasonically induced lung hemorrhage in neonatal swine," Ultrasound Med. Biol. 22, 119-128 (1996).
-
(1996)
Ultrasound Med. Biol.
, vol.22
, pp. 119-128
-
-
Baggs, R.1
Penney, D.P.2
Cox, C.3
Child, S.Z.4
Raeman, C.H.5
Dalecki, D.6
Carstensen, E.L.7
-
10
-
-
0030874224
-
Ultrasonically induced lung hemorrhage in young swine
-
D. Dalecki, S. Z. Child, C. H. Raeman, C. Cox, and E. L. Carstensen "Ultrasonically induced lung hemorrhage in young swine," Ultrasound Med. Biol. 23, 777-781 (1997).
-
(1997)
Ultrasound Med. Biol.
, vol.23
, pp. 777-781
-
-
Dalecki, D.1
Child, S.Z.2
Raeman, C.H.3
Cox, C.4
Carstensen, E.L.5
-
12
-
-
0033974629
-
-
Mechanical Bioeffects from Diagnostic Ultrasound: AIUM Consensus Statements (American Institute of Ultrasound in Medicine, Laurel, MD, 2000). Also, J. Ultrasound Med. 19, 67-168 (2000).
-
(2000)
J. Ultrasound Med.
, vol.19
, pp. 67-168
-
-
-
13
-
-
0040246156
-
Physical factors involved in ultrasonically induced change in living systems: II. Amplitude duration relations and the effect of hydrostatic pressure for nerve tissue
-
W. J. Fry, D. Tucker, F. J. Fry, and V. J. Wulff, "Physical factors involved in ultrasonically induced change in living systems: II. Amplitude duration relations and the effect of hydrostatic pressure for nerve tissue," J. Acoust. Soc. Am. 23, 364-368 (1951).
-
(1951)
J. Acoust. Soc. Am.
, vol.23
, pp. 364-368
-
-
Fry, W.J.1
Tucker, D.2
Fry, F.J.3
Wulff, V.J.4
-
14
-
-
0015381224
-
Ultrasonic exposure thresholds for changes in cells and tissues
-
C. R. Hill, "Ultrasonic exposure thresholds for changes in cells and tissues," J. Acoust. Soc. Am. 52, 667-672 (1972).
-
(1972)
J. Acoust. Soc. Am.
, vol.52
, pp. 667-672
-
-
Hill, C.R.1
-
15
-
-
0019490117
-
Pressure-mediated reduction of ultrasonically induced cell lysis
-
V. Ciaravino, M. W. Miller, and E. L. Carstensen, "Pressure-mediated reduction of ultrasonically induced cell lysis," Radiat. Res. 88, 209-213 (1981).
-
(1981)
Radiat. Res.
, vol.88
, pp. 209-213
-
-
Ciaravino, V.1
Miller, M.W.2
Carstensen, E.L.3
-
16
-
-
0021048330
-
Subharmonic emission as an indicator of ultrasonically-induced biological damage
-
K. I. Morton, G. R. terHaar, I. J. Statford, and C. R. Hill, "Subharmonic emission as an indicator of ultrasonically-induced biological damage," Ultrasound Med. Biol. 9, 629-633 (1983).
-
(1983)
Ultrasound Med. Biol.
, vol.9
, pp. 629-633
-
-
Morton, K.I.1
TerHaar, G.R.2
Statford, I.J.3
Hill, C.R.4
-
17
-
-
0023812147
-
Exposure levels for ultrasonic cavitation in the mouse neonate
-
C. S. Lee and L. A. Frizzell, "Exposure levels for ultrasonic cavitation in the mouse neonate," Ultrasound Med. Biol. 14, 735-742 (1988).
-
(1988)
Ultrasound Med. Biol.
, vol.14
, pp. 735-742
-
-
Lee, C.S.1
Frizzell, L.A.2
-
18
-
-
0020816201
-
Involvement of ultrasonically induced cavitation in the production of hind limb paralysis of the mouse neonate
-
L. A. Frizzell, C. S. Lee, P. D. Aschenbach, M. J. Borrelli, R. S. Morimoto, and F. Dunn, "Involvement of ultrasonically induced cavitation in the production of hind limb paralysis of the mouse neonate," J. Acoust. Soc. Am. 74, 1062-1065 (1983).
-
(1983)
J. Acoust. Soc. Am.
, vol.74
, pp. 1062-1065
-
-
Frizzell, L.A.1
Lee, C.S.2
Aschenbach, P.D.3
Borrelli, M.J.4
Morimoto, R.S.5
Dunn, F.6
-
19
-
-
0030983613
-
Correlation of ultrasound-induced hemolysis with cavitation detector output in vitro
-
E. C. Everhach, I. R. Makin, M. Azadniv, and R. S. Meltzer, "Correlation of ultrasound-induced hemolysis with cavitation detector output in vitro," Ultrasound Med. Biol. 23, 619-624 (1997).
-
(1997)
Ultrasound Med. Biol.
, vol.23
, pp. 619-624
-
-
Everhach, E.C.1
Makin, I.R.2
Azadniv, M.3
Meltzer, R.S.4
-
20
-
-
0030908558
-
Minimal static excess pressure minimizes the effect of extra-corporeal shock waves on cells and reduces it on gallstones
-
M. Delius, "Minimal static excess pressure minimizes the effect of extra-corporeal shock waves on cells and reduces it on gallstones," Ultrasound Med. Biol. 23, 611-617 (1997).
-
(1997)
Ultrasound Med. Biol.
, vol.23
, pp. 611-617
-
-
Delius, M.1
-
21
-
-
0000864939
-
SWL cavitation damage in vitro: Pressurization unmasks a differential response of foil targets and isolated cells
-
J. A. McAteer, M. A. Stonehill, K. Colmenares, J. C. Williams, A. P. Evan, R. O. Cleveland, M. R. Bailey, and L. A. Crum, "SWL cavitation damage in vitro: Pressurization unmasks a differential response of foil targets and isolated cells," Proc. 16th Intl. Congress on Acoustics, pp. 2497-2498 (1998).
-
(1998)
Proc. 16th Intl. Congress on Acoustics
, pp. 2497-2498
-
-
McAteer, J.A.1
Stonehill, M.A.2
Colmenares, K.3
Williams, J.C.4
Evan, A.P.5
Cleveland, R.O.6
Bailey, M.R.7
Crum, L.A.8
-
22
-
-
0005293531
-
Effect of overpressure on dissolution and cavitation of bubbles stabilized on a metal surface
-
R. O. Cleveland, M. R. Bailey, L. A. Crum, M. A. Stonehill, J. C. Williams, and J. A. McAteer, "Effect of overpressure on dissolution and cavitation of bubbles stabilized on a metal surface," Proc. 16th Intl. Congress on Acoustics, pp. 2499-2500 (1998).
-
(1998)
Proc. 16th Intl. Congress on Acoustics
, pp. 2499-2500
-
-
Cleveland, R.O.1
Bailey, M.R.2
Crum, L.A.3
Stonehill, M.A.4
Williams, J.C.5
McAteer, J.A.6
-
23
-
-
0022683317
-
Possibility of microcavitation from diagnostic ultrasound
-
R. E. Apfel, "Possibility of microcavitation from diagnostic ultrasound," IEEE Trans. Ultrason. Ferroelectr. Freq. Control UFFC-33, 139-142 (1986).
-
(1986)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.UFFC-33
, pp. 139-142
-
-
Apfel, R.E.1
-
24
-
-
0024627970
-
An improved theory for the prediction of microcavitation due to pulsed ultrasound
-
C. K. Holland and R. E. Apfel, "An improved theory for the prediction of microcavitation due to pulsed ultrasound," IEEE Trans. Ultrason. Ferroelectr. Freq. Control UFFC-36, 204-208 (1989).
-
(1989)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.UFFC-36
, pp. 204-208
-
-
Holland, C.K.1
Apfel, R.E.2
-
25
-
-
0001579807
-
Sonoluminscence and sonic chemiluininescence
-
E. N. Harvey, "Sonoluminscence and sonic chemiluininescence," J. Am. Chem. Soc. 61, 2392-2398 (1939).
-
(1939)
J. Am. Chem. Soc.
, vol.61
, pp. 2392-2398
-
-
Harvey, E.N.1
-
26
-
-
0000491038
-
The dependence of sonoluminescence on static pressure
-
R. D. Finch, "The dependence of sonoluminescence on static pressure," Br. J. Appl. Phys. 16, 1543-1553 (1965).
-
(1965)
Br. J. Appl. Phys.
, vol.16
, pp. 1543-1553
-
-
Finch, R.D.1
-
27
-
-
0000621120
-
Sonoluminescence and sonochemical reactions of aqueous carbon tetrachloride solutions
-
P. K. Chendke and H. S. Fogler, "Sonoluminescence and sonochemical reactions of aqueous carbon tetrachloride solutions," J. Phys. Chem. 87, 1362-1369 (1983).
-
(1983)
J. Phys. Chem.
, vol.87
, pp. 1362-1369
-
-
Chendke, P.K.1
Fogler, H.S.2
-
28
-
-
0006551662
-
Dependence of ultrasonic cavitation threshold on raised ambient pressure
-
J. Sponer, "Dependence of ultrasonic cavitation threshold on raised ambient pressure," Stud. Biophys. 137, 91-97 (1990).
-
(1990)
Stud. Biophys.
, vol.137
, pp. 91-97
-
-
Sponer, J.1
-
30
-
-
0031187748
-
Pulse-echo field distribution measurement technique of high-frequency ultrasound sources
-
K. Raum and W. D. O'Brien, Jr., "Pulse-echo field distribution measurement technique of high-frequency ultrasound sources," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 44, 810-815 (1997).
-
(1997)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.44
, pp. 810-815
-
-
Raum, K.1
O'Brien Jr., W.D.2
-
33
-
-
0035263393
-
Attenuation coefficient estimates of mouse and rat chest wall
-
in press
-
G. A. Teotico, R. J. Miller, L. A. Frizzell, J. F. Zachary, and W. D. O'Brien, Jr., "Attenuation coefficient estimates of mouse and rat chest wall," IEEE Trans. Ultrason. Ferroelectr. Freq. Control (in press).
-
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
-
-
Teotico, G.A.1
Miller, R.J.2
Frizzell, L.A.3
Zachary, J.F.4
O'Brien Jr., W.D.5
-
34
-
-
0032875680
-
Interlaboratory comparison of ultrasonic backscatter, attenuation and speed measurements
-
E. L. Madsen, F. Dong, G. R. Frank, B. S. Gara, K. A. Wear, T. Wilson, J. A. Zagzebski, H. L. Miller, K. K. Shung, S. H. Wang, E. J. Feleppa, T. Liu, W. D. O'Brien, Jr., K. A. Topp, N. T. Sanghvi, A. V. Zaitsen, T. J. Hall, J. B. Fowlkes, O. D. Kripfgans, and J. G. Miller, "Interlaboratory comparison of ultrasonic backscatter, attenuation and speed measurements," J. Ultrasound Med. 18, 615-631 (1999).
-
(1999)
J. Ultrasound Med.
, vol.18
, pp. 615-631
-
-
Madsen, E.L.1
Dong, F.2
Frank, G.R.3
Gara, B.S.4
Wear, K.A.5
Wilson, T.6
Zagzebski, J.A.7
Miller, H.L.8
Shung, K.K.9
Wang, S.H.10
Feleppa, E.J.11
Liu, T.12
O'Brien Jr., W.D.13
Topp, K.A.14
Sanghvi, N.T.15
Zaitsen, A.V.16
Hall, T.J.17
Fowlkes, J.B.18
Kripfgans, O.D.19
Miller, J.G.20
more..
-
37
-
-
72949137194
-
Physical characteristics of the chest and lungs and the work of breathing in different mammalian species
-
London
-
M. L. Crosfill and J. G. Widdicombe, "Physical characteristics of the chest and lungs and the work of breathing in different mammalian species," J. Physiol. (London) 158, 1-14 (1961).
-
(1961)
J. Physiol.
, vol.158
, pp. 1-14
-
-
Crosfill, M.L.1
Widdicombe, J.G.2
-
38
-
-
0002715524
-
Comparative quantitative morphology of the mammalian lung: Diffusing area
-
S. M. Tenney and J. E. Remmers, "Comparative quantitative morphology of the mammalian lung: Diffusing area," Nature (London) 197, 54-56 (1963).
-
(1963)
Nature (London)
, vol.197
, pp. 54-56
-
-
Tenney, S.M.1
Remmers, J.E.2
-
39
-
-
0008161844
-
Dimensions of the tracheobronchial tree and alveoli
-
edited by P. L. Altman and D. S. Dittmer Federation of American Societies for Experimental Biology, Bethedsa, MD
-
E. R. Weibel, "Dimensions of the tracheobronchial tree and alveoli," in Biological Handbooks: Respiration and Circulation, edited by P. L. Altman and D. S. Dittmer (Federation of American Societies for Experimental Biology, Bethedsa, MD, 1971), pp. 930-939.
-
(1971)
Biological Handbooks: Respiration and Circulation
, pp. 930-939
-
-
Weibel, E.R.1
-
40
-
-
0023702838
-
Transient pulsations of small gas bubbles in water
-
H. G. Flynn and C. C. Church, "Transient pulsations of small gas bubbles in water," J. Acoust. Soc. Am. 84, 985-998 (1988).
-
(1988)
J. Acoust. Soc. Am.
, vol.84
, pp. 985-998
-
-
Flynn, H.G.1
Church, C.C.2
-
41
-
-
0029751095
-
Bioeffects of positive and negative acoustic pressures in vivo
-
M. R. Bailey, D. Dalecki, S. Z. Child, C. H. Raeman, D. P. Penney, D. T. Blackstock, and E. L. Carstensen, "Bioeffects of positive and negative acoustic pressures in vivo," J. Acoust. Soc. Am. 100, 3941-3946 (1996).
-
(1996)
J. Acoust. Soc. Am.
, vol.100
, pp. 3941-3946
-
-
Bailey, M.R.1
Dalecki, D.2
Child, S.Z.3
Raeman, C.H.4
Penney, D.P.5
Blackstock, D.T.6
Carstensen, E.L.7
-
42
-
-
0032900317
-
Nonlinear propagation of the output indices
-
E. L. Carstensen, D. Dalecki, S. M. Gracewski, and T. Christopher, "Nonlinear propagation of the output indices," J. Ultrasound Med. 18, 69-80 (1999).
-
(1999)
J. Ultrasound Med.
, vol.18
, pp. 69-80
-
-
Carstensen, E.L.1
Dalecki, D.2
Gracewski, S.M.3
Christopher, T.4
-
43
-
-
0030050629
-
Exposure-time dependence of the threshold for ultrasonically induced murine lung hemorrhage
-
C. H. Raeman, S. Z. Child, D. Dalecki, C. Cox, and E. L. Carstensen, "Exposure-time dependence of the threshold for ultrasonically induced murine lung hemorrhage," Ultrasound Med. Biol. 22, 139-141 (1996).
-
(1996)
Ultrasound Med. Biol.
, vol.22
, pp. 139-141
-
-
Raeman, C.H.1
Child, S.Z.2
Dalecki, D.3
Cox, C.4
Carstensen, E.L.5
-
44
-
-
0016163845
-
Attenuation and reflection of ultrasound in canine lung tissue
-
T. J. Bauld and H. P. Schwan, "Attenuation and reflection of ultrasound in canine lung tissue," J. Acoust. Soc. Am. 56, 1630-1637 (1974).
-
(1974)
J. Acoust. Soc. Am.
, vol.56
, pp. 1630-1637
-
-
Bauld, T.J.1
Schwan, H.P.2
-
45
-
-
0016129332
-
Attenuation and speed of ultrasound in lung
-
F. Dunn, "Attenuation and speed of ultrasound in lung," J. Acoust. Soc. Am. 56, 1638-1639 (1974).
-
(1974)
J. Acoust. Soc. Am.
, vol.56
, pp. 1638-1639
-
-
Dunn, F.1
|