메뉴 건너뛰기




Volumn 17, Issue 3, 2003, Pages 299-301

The relationship between the diameters of the adult cricoid ring and main tracheobronchial tree: A cadaver study to investigate the basis for double-lumen tube selection

Author keywords

Cricoid cartilage; Double lumen tube size; Glottis; Larynx; Measurement; Thoracic; Tracheobronchial tree

Indexed keywords

ADULT; ANESTHESIOLOGICAL TECHNIQUES; ARTICLE; AUTOPSY; BRONCHUS; CADAVER; CRICOID; DOUBLE LUMEN TUBE; FEMALE; HUMAN; HUMAN TISSUE; LARYNX; MALE; PRIORITY JOURNAL; PROSPECTIVE STUDY; SURGICAL ANATOMY; TRACHEA; TRACHEOBRONCHIAL TREE;

EID: 0038798791     PISSN: 10530770     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1053-0770(03)00057-0     Document Type: Article
Times cited : (30)

References (13)
  • 1
    • 0036247074 scopus 로고    scopus 로고
    • A cadaver study to measure the adult glottis and subglottis: Defining a problem associated with the use of double-lumen tubes
    • Seymour AH, Prakash N: A cadaver study to measure the adult glottis and subglottis: Defining a problem associated with the use of double-lumen tubes. J Cardiothorac Vasc Anesth 16:196-198, 2002
    • (2002) J Cardiothorac Vasc Anesth , vol.16 , pp. 196-198
    • Seymour, A.H.1    Prakash, N.2
  • 2
    • 0000091955 scopus 로고
    • Low-resistance double-lumen endobronchial tubes
    • Robertshaw FL: Low-resistance double-lumen endobronchial tubes. Br J Anaesth 34:576-579, 1962
    • (1962) Br J Anaesth , vol.34 , pp. 576-579
    • Robertshaw, F.L.1
  • 3
    • 0001091748 scopus 로고
    • The dimensional interrelationships of the major components of the human tracheobronchial tree
    • Jesseph JE, Merendino KA: The dimensional interrelationships of the major components of the human tracheobronchial tree. Surg Gynec Obstet 105:210-214, 1957
    • (1957) Surg Gynec Obstet , vol.105 , pp. 210-214
    • Jesseph, J.E.1    Merendino, K.A.2
  • 5
    • 0029998807 scopus 로고    scopus 로고
    • Tracheal diameter predicts double-lumen tube size: A method for selecting left double-lumen tubes
    • Brodsky JB, Macario A, Mark JBD: Tracheal diameter predicts double-lumen tube size: a method for selecting left double-lumen tubes. Anesth Analg 82:861-864, 1996
    • (1996) Anesth Analg , vol.82 , pp. 861-864
    • Brodsky, J.B.1    Macario, A.2    Mark, J.B.D.3
  • 6
    • 0035073646 scopus 로고    scopus 로고
    • The relationship between tracheal width and left bronchial width: Implications for left-sided double-lumen tube selection
    • Brodsky JB, Malott K, Angst M, et al: The relationship between tracheal width and left bronchial width: Implications for left-sided double-lumen tube selection. J Cardiothorac Vasc Anesth 15:216-217, 2001
    • (2001) J Cardiothorac Vasc Anesth , vol.15 , pp. 216-217
    • Brodsky, J.B.1    Malott, K.2    Angst, M.3
  • 8
    • 0032871486 scopus 로고    scopus 로고
    • Computer tomographybased tracheobronchial image reconstruction allows selection of the individually appropriate double-lumen tube size
    • Eberle B, Weiler N, Vogel N, et al: Computer tomographybased tracheobronchial image reconstruction allows selection of the individually appropriate double-lumen tube size. J Cardiothorac Vasc Anesth 13:532-537, 1999
    • (1999) J Cardiothorac Vasc Anesth , vol.13 , pp. 532-537
    • Eberle, B.1    Weiler, N.2    Vogel, N.3
  • 9
    • 0031003952 scopus 로고    scopus 로고
    • Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter
    • Hannallah MS, Benumof JL, Silverman PM, et al: Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter. J Cardiothorac Vasc Anesth 11:168-171, 1997
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 168-171
    • Hannallah, M.S.1    Benumof, J.L.2    Silverman, P.M.3
  • 10
    • 0032909192 scopus 로고    scopus 로고
    • Predicting the size of a double-lumen endobronchial tube using computed tomographic scan measurements of the left main bronchus diameter
    • Chow MY, Liam BL, Thng CH, et al: Predicting the size of a double-lumen endobronchial tube using computed tomographic scan measurements of the left main bronchus diameter. Anesth Analg 88: 302-305, 1999
    • (1999) Anesth Analg , vol.88 , pp. 302-305
    • Chow, M.Y.1    Liam, B.L.2    Thng, C.H.3
  • 11
    • 0022186650 scopus 로고
    • Bronchial intubation. A comparison between polyvinylchloride and red rubber double-lumen tubes
    • Clapham MCC, Vaughan RS: Bronchial intubation. A comparison between polyvinylchloride and red rubber double-lumen tubes. Anaesthesia 40:1111-1114, 1985
    • (1985) Anaesthesia , vol.40 , pp. 1111-1114
    • Clapham, M.C.C.1    Vaughan, R.S.2
  • 12
    • 0023449789 scopus 로고
    • Margin of safety in positioning modern double-lumen endotracheal tubes
    • Benumof JL, Partridge BL, Savatierra C, et al: Margin of safety in positioning modern double-lumen endotracheal tubes. Anesthesiology 67:729-738, 1987
    • (1987) Anesthesiology , vol.67 , pp. 729-738
    • Benumof, J.L.1    Partridge, B.L.2    Savatierra, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.