Volumn 104, Issue 6, 2003, Pages 599-605

Influence of leg position and environmental temperature on segmental volume expansion during venous occlusion plethysmography

Author keywords

Blood redistribution; Environmental temperature; Leg position; Strain gauge plethysmography; Sympathetic tone; Venous compliance; Venous occlusion plethysmography

Indexed keywords

ACCURACY; ADULT; ARTICLE; BLOOD VOLUME; BODY POSITION; ENVIRONMENTAL TEMPERATURE; FEMALE; GASTROCNEMIUS MUSCLE; HUMAN; LEG; MALE; MEASUREMENT; NORMAL HUMAN; PRIORITY JOURNAL; STRAIN GAUGE PLETHYSMOGRAPH; SYMPATHETIC TONE; TECHNIQUE; THIGH; VEIN BLOOD FLOW; VEIN COMPLIANCE; VEIN OCCLUSION PLETHYSMOGRAPHY; VENOUS PRESSURE;

EID: 0038792358     PISSN: 01435221     EISSN: None     Source Type: Journal    
DOI: 10.1042/CS20020257     Document Type: Article
Times cited : (14)

References (13)
  • 1
    • 3042775519 scopus 로고
    • The measurement of volume changes in human limbs
    • Whitney, R. J. (1953) The measurement of volume changes in human limbs. J. Physiol. (Cambridge, U.K.) 121, 1-27
    • (1953) J. Physiol. (Cambridge, U.K.) , vol.121 , pp. 1-27
    • Whitney, R.J.1
  • 2
    • 0000371772 scopus 로고
    • Methods for the investigation of peripheral blood flow
    • Greenfield, A. D. M., Whitney, R. J. and Mowbray, J. F. (1963) Methods for the investigation of peripheral blood flow. Br. Med. Bull. 19, 101-109
    • (1963) Br. Med. Bull. , vol.19 , pp. 101-109
    • Greenfield, A.D.M.1    Whitney, R.J.2    Mowbray, J.F.3
  • 3
    • 0002174093 scopus 로고
    • On clinical use of venous occlusion plethysmography of calf, I. Methods and controls
    • Dahn, I. (1965) On clinical use of venous occlusion plethysmography of calf, I. Methods and controls. Acta Chir. Scand. 130, 42-60
    • (1965) Acta Chir. Scand. , vol.130 , pp. 42-60
    • Dahn, I.1
  • 4
    • 0038253677 scopus 로고
    • Three plethysmographs usable during functional states recording volume changes in ml per 100 ml of extremity
    • Dohn, K. (1956) Three plethysmographs usable during functional states recording volume changes in ml per 100 ml of extremity. Rep. Steno. Mem. Hosp. Nord. Insulinlab. 6, 147-168
    • (1956) Rep. Steno. Mem. Hosp. Nord. Insulinlab. , vol.6 , pp. 147-168
    • Dohn, K.1
  • 5
    • 84980115027 scopus 로고
    • Untersuchungen über eigenschaften und verwendungsmöglichkeiten eines flexible extremitätenplethysmografen
    • Graf, K. and Westersten, A. (1959) Untersuchungen über Eigenschaften und Verwendungsmöglichkeiten eines flexible Extremitätenplethysmografen. Acta Physiol. Scand. 46, 1-18
    • (1959) Acta Physiol. Scand. , vol.46 , pp. 1-18
    • Graf, K.1    Westersten, A.2
  • 6
    • 0037916132 scopus 로고
    • On the calibration and accuracy of segmental calf plethysmography with a description of a new expansion chamber and a new sleeve
    • Dahn, I. (1964) On the calibration and accuracy of segmental calf plethysmography with a description of a new expansion chamber and a new sleeve. Scand. J. Clin. Lab. Invest. 16, 347-356
    • (1964) Scand. J. Clin. Lab. Invest. , vol.16 , pp. 347-356
    • Dahn, I.1
  • 7
    • 0002025308 scopus 로고
    • Volume plethysmography in vascular disease: An overview
    • Bernstein, E. F., ed., CV Mosby Co., St Louis
    • Sumner, D. S. (1985) Volume plethysmography in vascular disease: an overview. In: Noninvasive Diagnostic Techniques in Vascular Disease (Bernstein, E. F., ed.), pp. 97-118., CV Mosby Co., St Louis
    • (1985) Noninvasive Diagnostic Techniques in Vascular Disease , pp. 97-118
    • Sumner, D.S.1
  • 9
    • 0013801624 scopus 로고
    • Effect of local exercise of forearm muscles on forearm capacitance vessels
    • Bevegård, B. S. and Shepherd, J. T. (1965) Effect of local exercise of forearm muscles on forearm capacitance vessels. J. Appl. Physiol. 20, 968-974
    • (1965) J. Appl. Physiol. , vol.20 , pp. 968-974
    • Bevegård, B.S.1    Shepherd, J.T.2
  • 10
    • 0001455936 scopus 로고
    • Venous collection in forearm and hand measured by the strain-gauge and volume plethysmograph
    • Clarke, R. S. J. and Hellon, R. F. (1957) Venous collection in forearm and hand measured by the strain-gauge and volume plethysmograph. Clin. Sci. 16, 103-117
    • (1957) Clin. Sci. , vol.16 , pp. 103-117
    • Clarke, R.S.J.1    Hellon, R.F.2
  • 11
    • 0001392958 scopus 로고
    • Regulation of volume in postarteriolar vessels of the lower limb
    • Ludbrook, J. and Loughlin, J. (1964) Regulation of volume in postarteriolar vessels of the lower limb. Am. Heart J. 67, 493-507
    • (1964) Am. Heart J. , vol.67 , pp. 493-507
    • Ludbrook, J.1    Loughlin, J.2
  • 12
    • 0005021582 scopus 로고
    • The blood circulation in the human limb; observations on the differences between the proximal and the distal parts and remarks on the regulation of body temperature
    • Grant, R. T. and Pearson, R. S. B. (1938) The blood circulation in the human limb; observations on the differences between the proximal and the distal parts and remarks on the regulation of body temperature. Clin. Sci. 3, 119-139
    • (1938) Clin. Sci. , vol.3 , pp. 119-139
    • Grant, R.T.1    Pearson, R.S.B.2
  • 13
    • 4244134203 scopus 로고
    • Value of venous plethysmography in the diagnosis of venous thrombosis and for the evaluation of therapeutic results
    • Ahlbäck, S., Bygdeman, S. and Watz, R. (1977) Value of venous plethysmography in the diagnosis of venous thrombosis and for the evaluation of therapeutic results. Monogr. Standard. Cardioangiol. Methods 4, 54-58
    • (1977) Monogr. Standard. Cardioangiol. Methods , vol.4 , pp. 54-58
    • Ahlbäck, S.1    Bygdeman, S.2    Watz, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.