메뉴 건너뛰기




Volumn 20, Issue 6, 2003, Pages 451-456

Bispectral index monitoring in patients undergoing cardiac surgery under cardiopulmonary bypass

Author keywords

Cardiac Surgical Procedures, myocardial revascularization, coronary artery bypass; Diagnostic Techniques, Neurological, electroencephalography; Surgical Procedures, Operative, extracorporeal circulation, cardiopulmonary bypass

Indexed keywords

BETA ADRENERGIC RECEPTOR BLOCKING AGENT; CALCIUM CHANNEL BLOCKING AGENT; DIAZEPAM; DIGOXIN; DIPEPTIDYL CARBOXYPEPTIDASE INHIBITOR; ISOFLURANE; MIDAZOLAM; MORPHINE; THIOPENTAL; VASODILATOR AGENT; VECURONIUM;

EID: 0038778638     PISSN: 02650215     EISSN: None     Source Type: Journal    
DOI: 10.1017/S026502150300070X     Document Type: Article
Times cited : (46)

References (12)
  • 1
    • 0028935194 scopus 로고
    • Prediction of movement using bispectral electroencephalographic analysis during propofol/alfentanil or isoflurane/alfentanil anesthesia
    • Vernon JM, Lang E, Sebel PS, Manberg P. Prediction of movement using bispectral electroencephalographic analysis during propofol/alfentanil or isoflurane/alfentanil anesthesia. Anesth Analg 1995; 80: 780-785.
    • (1995) Anesth Analg , vol.80 , pp. 780-785
    • Vernon, J.M.1    Lang, E.2    Sebel, P.S.3    Manberg, P.4
  • 2
    • 0030023299 scopus 로고    scopus 로고
    • White PE Electro encephalogram bispectral analysis predicts the depth of midazolam-induced sedation
    • Liu J, Singh H, White PE Electro encephalogram bispectral analysis predicts the depth of midazolam-induced sedation. Anesthesiology 1996; 84: 64-69.
    • (1996) Anesthesiology , vol.84 , pp. 64-69
    • Liu, J.1    Singh, H.2
  • 3
    • 0028117016 scopus 로고
    • Bispectral analysis of the electroencephalogram correlates with patient movement to skin incision during propofol/nitrous oxide anesthesia
    • Kearse Jr LA, Manberg P, Chamoun N, Debros F, Zaslavsky A. Bispectral analysis of the electroencephalogram correlates with patient movement to skin incision during propofol/nitrous oxide anesthesia. Anesthesiology 1994; 81: 1365-1370.
    • (1994) Anesthesiology , vol.81 , pp. 1365-1370
    • Kearse L.A., Jr.1    Manberg, P.2    Chamoun, N.3    Debros, F.4    Zaslavsky, A.5
  • 4
    • 0030721955 scopus 로고    scopus 로고
    • Titration of volatile anesthetics using bispectral index facilitates recovery after ambulatory anesthesia
    • Song D, Joshi GP, White PE. Titration of volatile anesthetics using bispectral index facilitates recovery after ambulatory anesthesia. Anesthesiology 1997; 87: 842-848.
    • (1997) Anesthesiology , vol.87 , pp. 842-848
    • Song, D.1    Joshi, G.P.2    White, P.E.3
  • 5
    • 9844245889 scopus 로고    scopus 로고
    • Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil and nitrous oxide anesthesia
    • Gan TJ, Glass PS, Windsor A, et al. Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil and nitrous oxide anesthesia. Anesthesiology 1997; 87: 808-815.
    • (1997) Anesthesiology , vol.87 , pp. 808-815
    • Gan, T.J.1    Glass, P.S.2    Windsor, A.3
  • 6
    • 0025296246 scopus 로고
    • Does opioid 'Anesthesia' exist?
    • Hug CC. Does opioid 'Anesthesia' exist? Anesthesiology 1990; 73: 1-4.
    • (1990) Anesthesiology , vol.73 , pp. 1-4
    • Hug, C.C.1
  • 7
    • 0034024491 scopus 로고    scopus 로고
    • Fentanyl and midazolam anaesthesia for coronary bypass surgery: A clinical study of bispectral electroencephalogram analysis, drug concentrations and recall
    • Barr G, Anderson RE, Samuelsson S, Owall A, Jakobsson JG. Fentanyl and midazolam anaesthesia for coronary bypass surgery: a clinical study of bispectral electroencephalogram analysis, drug concentrations and recall. Br J Anaesth 2000; 84: 749-752.
    • (2000) Br J Anaesth , vol.84 , pp. 749-752
    • Barr, G.1    Anderson, R.E.2    Samuelsson, S.3    Owall, A.4    Jakobsson, J.G.5
  • 8
    • 0030693089 scopus 로고    scopus 로고
    • Effect of cardiopulmonary bypass and hypothermia on electroencephalographic variables
    • Doi M, Gajraj RJ, Mantzaridis H, Kenny GNC. Effect of cardiopulmonary bypass and hypothermia on electroencephalographic variables Anaesthesia 1997; 52: 1048-1055.
    • (1997) Anaesthesia , vol.52 , pp. 1048-1055
    • Doi, M.1    Gajraj, R.J.2    Mantzaridis, H.3    Kenny, G.N.C.4
  • 9
    • 0034989729 scopus 로고    scopus 로고
    • Monitoring level of sedation and bispectral EEG analysis between hypothermic and normothermic cardiopulmonary bypass
    • Schmidlin D, Haer P, Schmid ER. Monitoring level of sedation and bispectral EEG analysis between hypothermic and normothermic cardiopulmonary bypass. Br J Anaesth 2000; 86: 769-776.
    • (2000) Br J Anaesth , vol.86 , pp. 769-776
    • Schmidlin, D.1    Haer, P.2    Schmid, E.R.3
  • 10
    • 0028001498 scopus 로고
    • Technology assessment and the learning contamination bias
    • Roizen MF, Toledano A. Technology assessment and the learning contamination bias. Anesth Analg 1994; 79: 410-412.
    • (1994) Anesth Analg , vol.79 , pp. 410-412
    • Roizen, M.F.1    Toledano, A.2
  • 11
    • 4243714602 scopus 로고    scopus 로고
    • Use of bispectral EEG monitoring to evaluate training in anesthesia
    • Kumar A, De Deyne C, Struys M, Vundelinckx G, Heylen R. Use of bispectral EEG monitoring to evaluate training in anesthesia. Br J Anaesth 1999; 82 (Suppl): A47.
    • (1999) Br J Anaesth , vol.82 , Issue.SUPPL.
    • Kumar, A.1    De Deyne, C.2    Struys, M.3    Vundelinckx, G.4    Heylen, R.5
  • 12
    • 0034716487 scopus 로고    scopus 로고
    • Awareness during anaesthesia: A prospective case study
    • Sandin RH. Awareness during anaesthesia: a prospective case study. Lancet 2000; 355: 707-711.
    • (2000) Lancet , vol.355 , pp. 707-711
    • Sandin, R.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.