메뉴 건너뛰기




Volumn 38, Issue 5, 2003, Pages 263-268

Navigator-gated coronary magnetic resonance angiography using steady-state-free-precession : Comparison to standard T2-prepared gradient-echo and spiral imaging

Author keywords

Contrast; Coronary artery disease; Coronary magnetic resonance angiography; Coronary vessel; Motion

Indexed keywords

ANGIOCARDIOGRAPHY; ANIMAL EXPERIMENT; ARTICLE; BREATHING; CONTRAST; CONTROLLED STUDY; CORONARY ARTERY; DIAGNOSTIC IMAGING; IMAGE QUALITY; IMAGING SYSTEM; INTERMETHOD COMPARISON; MAGNETIC RESONANCE ANGIOGRAPHY; NONHUMAN; PRIORITY JOURNAL; SIGNAL NOISE RATIO; SWINE; THREE DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 0038753991     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004424-200305000-00004     Document Type: Article
Times cited : (54)

References (24)
  • 1
    • 14944360212 scopus 로고    scopus 로고
    • Coronary magnetic resonance angiography for the detection of coronary stenoses
    • Kim WY, Danias PG, Stuber M, et al. Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med. 2001;345:1863-1869.
    • (2001) N Engl J Med , vol.345 , pp. 1863-1869
    • Kim, W.Y.1    Danias, P.G.2    Stuber, M.3
  • 2
    • 0036087971 scopus 로고    scopus 로고
    • A direct comparison of noninvasive coronary angiography by electron beam tomography and navigator-echo-based magnetic resonance imaging for the detection of restenosis after coronary angioplasty
    • Ropers D, Regenfus M, Stilianakis N, et al. A direct comparison of noninvasive coronary angiography by electron beam tomography and navigator-echo-based magnetic resonance imaging for the detection of restenosis after coronary angioplasty. Invest Radiol. 2002;37:386-392.
    • (2002) Invest Radiol , vol.37 , pp. 386-392
    • Ropers, D.1    Regenfus, M.2    Stilianakis, N.3
  • 4
    • 0034799783 scopus 로고    scopus 로고
    • Direct comparison of 3D spiral vs. Cartesian gradient-echo coronary magnetic resonance angiography
    • Bornert P, Stuber M, Botnar RM, et al. Direct comparison of 3D spiral vs. Cartesian gradient-echo coronary magnetic resonance angiography. Magn Reson Med. 2001;46:789-794.
    • (2001) Magn Reson Med , vol.46 , pp. 789-794
    • Bornert, P.1    Stuber, M.2    Botnar, R.M.3
  • 5
    • 0037760762 scopus 로고    scopus 로고
    • Three-dimensional true-FISP coronary magnetic resonance angiography
    • Stuber M, Boemert P, Botnar RM, et al. Three-dimensional true-FISP coronary magnetic resonance angiography. Proc Soc Cardiovasc Magn Reson. 2001;1:157.
    • (2001) Proc Soc Cardiovasc Magn Reson , vol.1 , pp. 157
    • Stuber, M.1    Boemert, P.2    Botnar, R.M.3
  • 6
    • 0036235861 scopus 로고    scopus 로고
    • Three-dimensional true-FISP imaging of the coronary arteries: Improved contrast with T2-preparation
    • Shea SM, Deshpande VS, Chung YC, et al. Three-dimensional true-FISP imaging of the coronary arteries: improved contrast with T2-preparation. J Magn Reson Imaging. 2002;15:597-602.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 597-602
    • Shea, S.M.1    Deshpande, V.S.2    Chung, Y.C.3
  • 8
    • 0031884958 scopus 로고    scopus 로고
    • Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at 2 T
    • Duerk JL, Lewin JS, Wendt M, et al. Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at 2 T. J Magn Reson Imaging. 1998;8:203-208.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 203-208
    • Duerk, J.L.1    Lewin, J.S.2    Wendt, M.3
  • 9
    • 0001569514 scopus 로고    scopus 로고
    • Segmented true FISP - An improved technique for cine MR angiography
    • Carr J, Simonetti O, Kroeker R, et al. Segmented true FISP-an improved technique for cine MR angiography [abstract]. Proc Int Soc Magn Res Med. 2000;1:199.
    • (2000) Proc Int Soc Magn Res Med , vol.1 , pp. 199
    • Carr, J.1    Simonetti, O.2    Kroeker, R.3
  • 10
    • 0032719272 scopus 로고    scopus 로고
    • Cardiac motion of coronary arteries: Variability in the rest period and implications for coronary MR angiography
    • Wang Y, Vidan E, Bergman GW. Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. Radiology. 1999;213:751-758.
    • (1999) Radiology , vol.213 , pp. 751-758
    • Wang, Y.1    Vidan, E.2    Bergman, G.W.3
  • 11
    • 0037133176 scopus 로고    scopus 로고
    • Magnetic resonance-guided coronary artery stent placement in a swine model
    • Spuentrup E, Ruebben A, Schaeffter T, et al. Magnetic resonance-guided coronary artery stent placement in a swine model. Circulation. 2002; 105:874-879.
    • (2002) Circulation , vol.105 , pp. 874-879
    • Spuentrup, E.1    Ruebben, A.2    Schaeffter, T.3
  • 12
    • 0033594967 scopus 로고    scopus 로고
    • Improved coronary artery definition with T2-weighted free-breathing 3D-coronary MRA
    • Botnar RM, Stuber M, Danias PG, et al. Improved coronary artery definition with T2-weighted free-breathing 3D-coronary MRA. Circulation. 1999;99:3139-3148.
    • (1999) Circulation , vol.99 , pp. 3139-3148
    • Botnar, R.M.1    Stuber, M.2    Danias, P.G.3
  • 13
    • 0032701253 scopus 로고    scopus 로고
    • Double oblique free-breathing high-resolution 3D coronary MRA
    • Stuber M, Botnar RM, Danias PG, et al. Double oblique free-breathing high-resolution 3D coronary MRA. J Am Coll Cardiol. 1999;34:524-531.
    • (1999) J Am Coll Cardiol , vol.34 , pp. 524-531
    • Stuber, M.1    Botnar, R.M.2    Danias, P.G.3
  • 14
    • 0036828308 scopus 로고    scopus 로고
    • Navigator-gated free-breathing three-dimensional balanced FFE (TrueFISP) coronary MRA
    • Spuentrup E, Bomert P, Botnar RM, et al. Navigator-gated free-breathing three-dimensional balanced FFE (TrueFISP) coronary MRA. Invest Radiol. 2002;37:637-642.
    • (2002) Invest Radiol , vol.37 , pp. 637-642
    • Spuentrup, E.1    Bomert, P.2    Botnar, R.M.3
  • 15
    • 0032810872 scopus 로고    scopus 로고
    • Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: Comparison of navigator locations
    • Stuber M, Botnar RM, Danias PG, et al. Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. Radiology. 1999;212:579-587.
    • (1999) Radiology , vol.212 , pp. 579-587
    • Stuber, M.1    Botnar, R.M.2    Danias, P.G.3
  • 16
    • 0024453449 scopus 로고
    • Adaptive technique for high-definition MR imaging of moving structures
    • Ehman RL, Felmlee JP. Adaptive technique for high-definition MR imaging of moving structures. Radiology. 1989;173:255-263.
    • (1989) Radiology , vol.173 , pp. 255-263
    • Ehman, R.L.1    Felmlee, J.P.2
  • 17
    • 0034877825 scopus 로고    scopus 로고
    • The impact of navigator timing parameters and navigator spatial resolution on 3D coronary magnetic resonance angiography
    • Spuentrup E, Stuber M, Botnar RM, et al. The impact of navigator timing parameters and navigator spatial resolution on 3D coronary magnetic resonance angiography. J Magn Reson Imaging. 2001;14:311-318.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 311-318
    • Spuentrup, E.1    Stuber, M.2    Botnar, R.M.3
  • 18
    • 0025256166 scopus 로고
    • Fast algorithms for low-level vision
    • Deriche R. Fast algorithms for low-level vision. IEEE Trans PAML 1990;PAMI-12:78-87.
    • (1990) IEEE Trans PAML , vol.PAMI-12 , pp. 78-87
    • Deriche, R.1
  • 19
    • 0000715679 scopus 로고    scopus 로고
    • True FISP imaging with inherent fat cancellation
    • Deimling M, Held O. True FISP imaging with inherent fat cancellation [abstract]. Proc Intern Soc Magn Reson Med. 2000;1:1500.
    • (2000) Proc Intern Soc Magn Reson Med , vol.1 , pp. 1500
    • Deimling, M.1    Held, O.2
  • 20
    • 0035009703 scopus 로고    scopus 로고
    • Magnetization preparation during the steady state: Fat-saturated 3D TrueFISP. PG-1075-80
    • Scheffier K, Heid O, Hennig J. Magnetization preparation during the steady state: fat-saturated 3D TrueFISP. PG-1075-80. Magn Reson Med. 2001;45:1075-1080.
    • (2001) Magn Reson Med , vol.45 , pp. 1075-1080
    • Scheffier, K.1    Heid, O.2    Hennig, J.3
  • 21
    • 0036199531 scopus 로고    scopus 로고
    • Breath-hold three-dimensional true-FISP imaging of coronary arteries using asymmetric sampling
    • Deshpande VS, Shea SM, Chung YC, et al. Breath-hold three-dimensional true-FISP imaging of coronary arteries using asymmetric sampling. J Magn Reson Imaging. 2002;15:473-478.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 473-478
    • Deshpande, V.S.1    Shea, S.M.2    Chung, Y.C.3
  • 22
    • 0028904705 scopus 로고
    • A velocity k-space analysis of flow effects in echo-planar and spiral imaging
    • Nishimura DG, Irarrazabal P, Meyer CH. A velocity k-space analysis of flow effects in echo-planar and spiral imaging. Magn Reson Med. 1995;33:549-556.
    • (1995) Magn Reson Med , vol.33 , pp. 549-556
    • Nishimura, D.G.1    Irarrazabal, P.2    Meyer, C.H.3
  • 23
    • 0032999731 scopus 로고    scopus 로고
    • Differences between normal subjects and patients with coronary artery disease for three different MR coronary angiography respiratory suppression techniques
    • Taylor AM, Keegan J, Jhooti P, et al. Differences between normal subjects and patients with coronary artery disease for three different MR coronary angiography respiratory suppression techniques. J Magn Reson Imaging. 1999;9:786-793.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 786-793
    • Taylor, A.M.1    Keegan, J.2    Jhooti, P.3
  • 24
    • 0036829787 scopus 로고    scopus 로고
    • Real-time motion correction in navigator-gated free-breathing double-oblique submillimeter 3D right coronary artery magnetic resonance angiography
    • Spuentrup E, Stuber M, Bomar RM, et al. Real-time motion correction in navigator-gated free-breathing double-oblique submillimeter 3D right coronary artery magnetic resonance angiography. Invest Radiol. 2002; 37:632-636.
    • (2002) Invest Radiol , vol.37 , pp. 632-636
    • Spuentrup, E.1    Stuber, M.2    Bomar, R.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.