메뉴 건너뛰기




Volumn 22, Issue 3, 2003, Pages 255-260

Determining the reliability of ultrasound measurements and the validity of the formulae for ultrasound estimation of postvoid residual bladder volume in postpartum women

Author keywords

Bladder; Post partum; Ultrasound; Urinary retention; Validation

Indexed keywords

ARTICLE; BLADDER CAPACITY; BLADDER CATHETERIZATION; DIAGNOSTIC ACCURACY; DIAGNOSTIC ERROR; ECHOGRAPHY; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MICTURITION; PUERPERIUM; RELIABILITY; RESIDUAL URINE; URINE RETENTION; VALIDATION PROCESS;

EID: 0038753971     PISSN: 07332467     EISSN: None     Source Type: Journal    
DOI: 10.1002/nau.10112     Document Type: Article
Times cited : (30)

References (18)
  • 3
    • 0019305767 scopus 로고
    • Third report on the standardisation of terminology of lower urinary tract function. Procedures related to the evaluation of micturition: Pressure-flow relationships. Residual urine
    • Bates CP, Bradley WE, Glen ES, Griffiths D, Melchior H, Rowan D, Sterling A, Hald T. 1980. Third report on the standardisation of terminology of lower urinary tract function. Procedures related to the evaluation of micturition: pressure-flow relationships. Residual urine. Br J Urol 52:348-50.
    • (1980) Br J Urol , vol.52 , pp. 348-350
    • Bates, C.P.1    Bradley, W.E.2    Glen, E.S.3    Griffiths, D.4    Melchior, H.5    Rowan, D.6    Sterling, A.7    Hald, T.8
  • 4
    • 0030017818 scopus 로고    scopus 로고
    • Statistics notes: Measurement error proportional to the mean
    • Bland JM, Altman DG. 1996. Statistics notes: measurement error proportional to the mean. BMJ 313:106.
    • (1996) BMJ , vol.313 , pp. 106
    • Bland, J.M.1    Altman, D.G.2
  • 5
    • 0022543249 scopus 로고
    • Accuracy and repeatability of bladder volume measurement using ultrasonic imaging
    • Griffiths CJ, Murray A, Ramsden PD. 1986. Accuracy and repeatability of bladder volume measurement using ultrasonic imaging. J Urol 136:808-12.
    • (1986) J Urol , vol.136 , pp. 808-812
    • Griffiths, C.J.1    Murray, A.2    Ramsden, P.D.3
  • 7
    • 0023755826 scopus 로고
    • Diuretic response to fluid load in women with urinary incontinence: Optimum duration of pad test
    • Haylen BT, Frazer MI, Sutherst JR. 1988. Diuretic response to fluid load in women with urinary incontinence: optimum duration of pad test. Br J Urol 62:331-3.
    • (1988) Br J Urol , vol.62 , pp. 331-333
    • Haylen, B.T.1    Frazer, M.I.2    Sutherst, J.R.3
  • 8
    • 0024549743 scopus 로고
    • Transvaginal ultrasound in the assessment of bladder volumes in women: Preliminary report
    • Haylen BT, Frazer MI, Sutherst JR, West CR. 1989a. Transvaginal ultrasound in the assessment of bladder volumes in women: preliminary report. Br J Urol 63:149-51.
    • (1989) Br J Urol , vol.63 , pp. 149-151
    • Haylen, B.T.1    Frazer, M.I.2    Sutherst, J.R.3    West, C.R.4
  • 9
    • 0024589944 scopus 로고
    • The accuracy of measurement of residual urine in women by urethral catheterization
    • Haylen BT, Frazer MI, Sutherst JR, Ashby D. 1989b. The accuracy of measurement of residual urine in women by urethral catheterization. Br J Urol 63:152-4.
    • (1989) Br J Urol , vol.63 , pp. 152-154
    • Haylen, B.T.1    Frazer, M.I.2    Sutherst, J.R.3    Ashby, D.4
  • 10
    • 0024432695 scopus 로고
    • Assessing the effectiveness of different urinary catheters in emptying the bladder: An application of transvaginal ultrasound
    • Haylen BT, Frazer MI, MacDonald JH. 1989c. Assessing the effectiveness of different urinary catheters in emptying the bladder: an application of transvaginal ultrasound. Br J Urol 64:353-6.
    • (1989) Br J Urol , vol.64 , pp. 353-356
    • Haylen, B.T.1    Frazer, M.I.2    MacDonald, J.H.3
  • 13
    • 0024561765 scopus 로고
    • Accuracy of total bladder volume and residual urine measurements: Comparison between real-time ultrasonography and catheterization
    • Mainprize TC, Drutz HP. 1989. Accuracy of total bladder volume and residual urine measurements: comparison between real-time ultrasonography and catheterization. Am J Obstet Gynecol 160:1013-6.
    • (1989) Am J Obstet Gynecol , vol.160 , pp. 1013-1016
    • Mainprize, T.C.1    Drutz, H.P.2
  • 14
    • 0018184517 scopus 로고
    • Determination of bladder volumes by gray scale ultrasonography
    • McLean GK, Edell SL. 1978. Determination of bladder volumes by gray scale ultrasonography. Radiology 128:181-2.
    • (1978) Radiology , vol.128 , pp. 181-182
    • McLean, G.K.1    Edell, S.L.2
  • 15
    • 0019450416 scopus 로고
    • Applications of bladder ultrasonography. I. Bladder content and residue
    • Orgaz RE, Gomez AZ, Ramirez CT, Torres JLM. 1981. Applications of bladder ultrasonography. I. Bladder content and residue. J Urol 125:174-6.
    • (1981) J Urol , vol.125 , pp. 174-176
    • Orgaz, R.E.1    Gomez, A.Z.2    Ramirez, C.T.3    Torres, J.L.M.4
  • 16
    • 0016790517 scopus 로고
    • Residual urine determination by ultrasonic scanning
    • Pedersen JF, Bartrum RJ, Grytter C. 1975. Residual urine determination by ultrasonic scanning. Am J Roentgenol 125:474-8.
    • (1975) Am J Roentgenol , vol.125 , pp. 474-478
    • Pedersen, J.F.1    Bartrum, R.J.2    Grytter, C.3
  • 18
    • 0020536645 scopus 로고
    • The accuracy of ultrasound in the measurement of changes in bladder volume
    • Poston GJ, Joseph AEA, Riddle PR. 1983. The accuracy of ultrasound in the measurement of changes in bladder volume. Br J Urol 55:361-3.
    • (1983) Br J Urol , vol.55 , pp. 361-363
    • Poston, G.J.1    Joseph, A.E.A.2    Riddle, P.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.