메뉴 건너뛰기




Volumn 13, Issue 3, 2003, Pages 209-214

Renal parenchymal hemostatic aids: Glues and things

Author keywords

Hemorrhage; Hemostasis; Partial nephrectomy; Renal parenchyma

Indexed keywords

MACROGOL; TISSUE ADHESIVE;

EID: 0038741761     PISSN: 09630643     EISSN: None     Source Type: Journal    
DOI: 10.1097/00042307-200305000-00007     Document Type: Review
Times cited : (32)

References (22)
  • 1
    • 0027468220 scopus 로고
    • Nephron sparing surgery for renal cell carcinoma
    • Licht MR, Novick AC. Nephron sparing surgery for renal cell carcinoma. J Urol 1993; 145:1.
    • (1993) J Urol , vol.145 , pp. 1
    • Licht, M.R.1    Novick, A.C.2
  • 2
    • 0028209782 scopus 로고
    • Complications of nephron-sparing surgery for renal tumours
    • Campbell SC, Novick AC, Streem SB, et al. Complications of nephron-sparing surgery for renal tumours. J Urol 1994; 154:1177.
    • (1994) J Urol , vol.154 , pp. 1177
    • Campbell, S.C.1    Novick, A.C.2    Streem, S.B.3
  • 3
    • 0028241305 scopus 로고
    • Nephron sparing surgery in incidental versus suspected renal cell carcinoma
    • Licht MR, Novick AC, Goormastic M. Nephron sparing surgery in incidental versus suspected renal cell carcinoma. J Urol 1994; 152:39.
    • (1994) J Urol , vol.152 , pp. 39
    • Licht, M.R.1    Novick, A.C.2    Goormastic, M.3
  • 4
    • 0036144839 scopus 로고    scopus 로고
    • Laparoscopic partial nephrectomy for renal tumour: Duplicating open surgical techniques
    • Gill IS, Desai MM, Kaouk JH, et al. Laparoscopic partial nephrectomy for renal tumour: duplicating open surgical techniques. J Urol 2002; 167:469. This is an outstanding article defining the fact that laparoscopic partial nephrectomy is achievable without compromising cancer clearance.
    • (2002) J Urol , vol.167 , pp. 469
    • Gill, I.S.1    Desai, M.M.2    Kaouk, J.H.3
  • 5
    • 0036378343 scopus 로고    scopus 로고
    • The impact of arterial occlusion during partial nephrectomy on residual renal function: An evaluation with 99m technetium - DMSA scintigraphy
    • Kondo T, Nakazawa H, Ito F, et al. The impact of arterial occlusion during partial nephrectomy on residual renal function: an evaluation with 99m technetium - DMSA scintigraphy. Int J Urol 2002; 9:435.
    • (2002) Int J Urol , vol.9 , pp. 435
    • Kondo, T.1    Nakazawa, H.2    Ito, F.3
  • 6
    • 0038574065 scopus 로고    scopus 로고
    • New technique: Hand assisted laparoscopic partial nephrectomy with hypothermia: Animal model data and early human application
    • Duke H, Baldwin D, Porter J, Langenstroer P. New technique: hand assisted laparoscopic partial nephrectomy with hypothermia: animal model data and early human application [abstract]. J Endourol 2002; 16:A20. A point of technique outlining a novel method to achieve renal cooling.
    • (2002) J Endourol , vol.16
    • Duke, H.1    Baldwin, D.2    Porter, J.3    Langenstroer, P.4
  • 7
    • 0036390840 scopus 로고    scopus 로고
    • Renal hypothermia achieved by retrograde intracavitary saline perfusion
    • Landman J, Rehman J, Sundaram C, et al. Renal hypothermia achieved by retrograde intracavitary saline perfusion. J Endourol 2002; 16:445. Point of technique outlining a novel method to achieve renal cooling during laparoscopic surgery.
    • (2002) J Endourol , vol.16 , pp. 445
    • Landman, J.1    Rehman, J.2    Sundaram, C.3
  • 8
    • 0036160822 scopus 로고    scopus 로고
    • The use of fibrin sealant in urology
    • Shekarriz B, Stoller M. The use of fibrin sealant in urology. J Urol 2002; 167:1218. Comprehensive review of the history, biology and contemporary use of fibrin glue in urology.
    • (2002) J Urol , vol.167 , pp. 1218
    • Shekarriz, B.1    Stoller, M.2
  • 9
    • 84856076583 scopus 로고
    • Ueber wirkungen des fibrins
    • Bergel S. Ueber wirkungen des fibrins. Dtsch Med Wochenschr 1909; 35:633.
    • (1909) Dtsch Med Wochenschr , vol.35 , pp. 633
    • Bergel, S.1
  • 10
    • 0030903558 scopus 로고    scopus 로고
    • Fibrin sealant: Scientific rationale, production methods, properties and current clinical use
    • Radosevich M, Goubran H, Burnouf T. Fibrin sealant: scientific rationale, production methods, properties and current clinical use. Vox Sang 1997; 72:133.
    • (1997) Vox Sang , vol.72 , pp. 133
    • Radosevich, M.1    Goubran, H.2    Burnouf, T.3
  • 11
    • 0037897829 scopus 로고    scopus 로고
    • Hand assisted laparoscopic (HAL) heminephrectomy in pigs utilizing AFAB
    • Donaldson A, Jackman S. Hand assisted laparoscopic (HAL) heminephrectomy in pigs utilizing AFAB. J Endourol 2002; 16:A20.
    • (2002) J Endourol , vol.16
    • Donaldson, A.1    Jackman, S.2
  • 12
    • 0036393472 scopus 로고    scopus 로고
    • Local hemostasis during laparoscopic partial nephrectomy using biodegradable hydrogels: Initial porcine experience
    • Ramakumar S, Roberts W, Fugita O, et al. Local hemostasis during laparoscopic partial nephrectomy using biodegradable hydrogels: initial porcine experience. J Endourol 2002; 16:489. Excellent scientific study of a new hemostatic technique.
    • (2002) J Endourol , vol.16 , pp. 489
    • Ramakumar, S.1    Roberts, W.2    Fugita, O.3
  • 13
    • 4243215357 scopus 로고    scopus 로고
    • In vivo application and pressure testing of biodegradable hydrogels for hemostasis in a porcine laparoscopic partial nephrectomy model
    • Ramakumar S, Park E, Nelson J, et al. In vivo application and pressure testing of biodegradable hydrogels for hemostasis in a porcine laparoscopic partial nephrectomy model. J Endourol 2002; 16:A21.
    • (2002) J Endourol , vol.16
    • Ramakumar, S.1    Park, E.2    Nelson, J.3
  • 14
    • 0036229727 scopus 로고    scopus 로고
    • Cross-linked tissue sealant protects against mortality and hemorrhage in an acute renal injury model in heparinized rats
    • Petratos P, Ito K, Felson D, Poppas D. Cross-linked tissue sealant protects against mortality and hemorrhage in an acute renal injury model in heparinized rats. J Urol 2002; 167:2222. Excellent scientific study of a new hemostatic technique albeit in a rat model.
    • (2002) J Urol , vol.167 , pp. 2222
    • Petratos, P.1    Ito, K.2    Felson, D.3    Poppas, D.4
  • 15
    • 4244161742 scopus 로고    scopus 로고
    • Sutureless laparoscopic heminephrectomy using laser tissue soldering in the porcine model
    • Ogan K, Jacomides L, Napper C, et al. Sutureless laparoscopic heminephrectomy using laser tissue soldering in the porcine model. J Endourol 2002; 16(1):A21. Excellent scientific study of a new hemostatic technique.
    • (2002) J Endourol , vol.16 , Issue.1
    • Ogan, K.1    Jacomides, L.2    Napper, C.3
  • 16
    • 24244461964 scopus 로고    scopus 로고
    • Feasibility of laparoscopic partial nephrectomy using pledgeted compression sutures for hemostasis
    • Wilhelm D, Ogan K, Saboorian M, et al. Feasibility of laparoscopic partial nephrectomy using pledgeted compression sutures for hemostasis. J Endourol 2002; 16:A21. Excellent scientific study of a new hemostatic technique.
    • (2002) J Endourol , vol.16
    • Wilhelm, D.1    Ogan, K.2    Saboorian, M.3
  • 17
    • 0036227613 scopus 로고    scopus 로고
    • Endoloop assisted laparoscopic partial nephrectomy
    • Beck S, Lifshitz D, Cheng L, et al. Endoloop assisted laparoscopic partial nephrectomy. J Endourol 2002; 16:175. This is an excellent scientific study of a new hemostatic technique.
    • (2002) J Endourol , vol.16 , pp. 175
    • Beck, S.1    Lifshitz, D.2    Cheng, L.3
  • 18
    • 4243215358 scopus 로고    scopus 로고
    • Further experience with hydro-jet dissection for renal sparing surgery
    • Shekkariz B, Upadhyay J, Jewett M. Further experience with hydro-jet dissection for renal sparing surgery. J Endourol 2002; 16:A24.
    • (2002) J Endourol , vol.16
    • Shekkariz, B.1    Upadhyay, J.2    Jewett, M.3
  • 20
    • 4243215356 scopus 로고    scopus 로고
    • Efficacy of ultrasonic tissue dissector and tissue glue for laparoscopic partial nephrectomy in a porcine model
    • Huang S, Chiu A, Lin C, et al. Efficacy of ultrasonic tissue dissector and tissue glue for laparoscopic partial nephrectomy in a porcine model. J Endourol 2002; 16:A24. This is a description of a new hemostatic technique.
    • (2002) J Endourol , vol.16
    • Huang, S.1    Chiu, A.2    Lin, C.3
  • 21
    • 0036627357 scopus 로고    scopus 로고
    • The clinical use of the holmium: YAG laser in laparoscopic partial nephrectomy
    • Lotan Y, Gettman M, Ogan K, et al. The clinical use of the holmium:YAG laser in laparoscopic partial nephrectomy. J Endourol 2002; 16:289. This is an excellent scientific study of a new hemostatic technique.
    • (2002) J Endourol , vol.16 , pp. 289
    • Lotan, Y.1    Gettman, M.2    Ogan, K.3
  • 22
    • 0035996240 scopus 로고    scopus 로고
    • Application of microwave tissue coagulator: Is it beneficial to partial nephrectomy?
    • Matsui Y, Fujikawa K, Hiroshi I, et al. Application of microwave tissue coagulator: is it beneficial to partial nephrectomy? Urol Int 2002; 69:27.
    • (2002) Urol Int , vol.69 , pp. 27
    • Matsui, Y.1    Fujikawa, K.2    Hiroshi, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.