메뉴 건너뛰기




Volumn 50, Issue 3, 2003, Pages 393-397

A HOTLink/Networked PC Data Acquisition and Image Reconstruction System for a High-Resolution Whole-Body PET With Respiratory or ECG-Gated Performance

Author keywords

Data acquisition; nuclear imaging; positron emission tomography (PET); serial bus

Indexed keywords

DATA ACQUISITION; DATA COMMUNICATION EQUIPMENT; DIGITAL IMAGE STORAGE; ELECTROCARDIOGRAPHY; FIBER OPTIC NETWORKS; IMAGE RECONSTRUCTION; IMAGE SEGMENTATION; LOCAL AREA NETWORKS; PERSONAL COMPUTERS; PIPELINE PROCESSING SYSTEMS; USER INTERFACES; X RAY CAMERAS;

EID: 0038720403     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/TNS.2003.812441     Document Type: Article
Times cited : (4)

References (11)
  • 1
    • 0036815778 scopus 로고    scopus 로고
    • The design of a high resolution transformable whole body PET camera
    • Oct.
    • W. H. Wong, “The design of a high resolution transformable whole body PET camera,” IEEE Trans. Nucl. Sci., vol. 49, Oct. 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49
    • Wong, W.H.1
  • 4
    • 85008035745 scopus 로고    scopus 로고
    • CY7B933, Cypress Semiconductor Co.
    • Datasheets for CY7B923, CY7B933, Cypress Semiconductor Co.
    • Datasheets for CY7B923
  • 5
    • 0036305067 scopus 로고    scopus 로고
    • Effect of respiratory gating on quantifying PET images of lung cancer
    • S. A. Nehmeh et al., “Effect of respiratory gating on quantifying PET images of lung cancer,” J. Nucl. Medicine, vol. 43, pp. 876-881, 2002.
    • (2002) J. Nucl. Medicine , vol.43 , pp. 876-881
    • Nehmeh, S.A.1
  • 6
    • 0030810148 scopus 로고    scopus 로고
    • Automatic quantification of regional myocardial wall motion and thickening from gated technetium-99 m sestamibi myocardial perfusion single photon emission computed tomography
    • G. Germano et al., “Automatic quantification of regional myocardial wall motion and thickening from gated technetium-99 m sestamibi myocardial perfusion single photon emission computed tomography,” J. Amer. Coll. Cardiol., vol. 30, pp. 1360-1367, 1997.
    • (1997) J. Amer. Coll. Cardiol. , vol.30 , pp. 1360-1367
    • Germano, G.1
  • 7
    • 0037700114 scopus 로고    scopus 로고
    • A modular low dead-time coincidence system for high resolution PET cameras
    • Y. Wang et al., “A modular low dead-time coincidence system for high resolution PET cameras,” Conf. Rec. 2002 IEEE MIC.
    • Conf. Rec. 2002 IEEE MIC.
    • Wang, Y.1
  • 8
    • 85008012617 scopus 로고    scopus 로고
    • User Guide for PCI-6534, Nat
    • Instrument.
    • User Guide for PCI-6534, Nat. Instrument.
  • 10
    • 0030170247 scopus 로고    scopus 로고
    • Design of a variable filed prototype PET camera
    • June
    • W. H. Wong, J. Uribe, W. Lu, and K. Hicks, “Design of a variable filed prototype PET camera,” IEEE Trans. Nucl. Sci., vol. 36, pp. 1915-1920, June 1996.
    • (1996) IEEE Trans. Nucl. Sci. , vol.36 , pp. 1915-1920
    • Wong, W.H.1    Uribe, J.2    Lu, W.3    Hicks, K.4
  • 11
    • 0033321729 scopus 로고    scopus 로고
    • Basic imaging characteristics of a variable field of view PET camera using quadrant sharing detector design
    • June
    • J. Uribe, H. Baghaei, H. Li, S. Yokoyama, N. Zhang, J.Wang, F. Dobbs, and W. H. Wong, “Basic imaging characteristics of a variable field of view PET camera using quadrant sharing detector design,” IEEE Trans. Nucl. Sci., vol. 46, pp. 491-497, June 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , pp. 491-497
    • Uribe, J.1    Baghaei, H.2    Li, H.3    Yokoyama, S.4    Zhang, N.5    Wang, J.6    Dobbs, F.7    Wong, W.H.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.