Improved patency of prosthetic arteriovenous grafts with an acute anastomotic angle and flow diffuser

Author keywords

[No Author keywords available]

Indexed keywords

POLITEF;

EID: 0038710699     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1067/mva.2003.187     Document Type: Article
Times cited : (9)

References (9)
  • 1
    • 0028920731 scopus 로고
    • The anastomosis angle does change the flow fields at vascular end-to-side anastomoses in vivo
    • Staalsen N-H, Ulrich M, Winther J, Pedersen EM, How T, Nygaard H. The anastomosis angle does change the flow fields at vascular end-to-side anastomoses in vivo. J Vasc Surg 1995;21:460-71.
    • (1995) J Vasc Surg , vol.21 , pp. 460-471
    • Staalsen, N.-H.1    Ulrich, M.2    Winther, J.3    Pedersen, E.M.4    How, T.5    Nygaard, H.6
  • 2
    • 0018967987 scopus 로고
    • Flow disturbance at the distal end-to-side anastomosis: Effect of patency of the proximal outflow segment and angle of anastomosis
    • Crawshaw HM, Quist WC, Serallach E, Valeri CR, LoGerfo FW. Flow disturbance at the distal end-to-side anastomosis: Effect of patency of the proximal outflow segment and angle of anastomosis. Arch Surg 1980;115:1280.
    • (1980) Arch Surg , vol.115 , pp. 1280
    • Crawshaw, H.M.1    Quist, W.C.2    Serallach, E.3    Valeri, C.R.4    LoGerfo, F.W.5
  • 3
    • 0031821757 scopus 로고    scopus 로고
    • Impedance index measurements of in vitro PTFE end-to-side anastomoses: Effect of angle and Miller cuff
    • Wijesinghe LD, Smye SW, Scott DJA. Impedance index measurements of in vitro PTFE end-to-side anastomoses: Effect of angle and Miller cuff. Eur J Vasc Endovasc Surg 1998;16:65-70.
    • (1998) Eur J Vasc Endovasc Surg , vol.16 , pp. 65-70
    • Wijesinghe, L.D.1    Smye, S.W.2    Scott, D.J.A.3
  • 4
    • 0030560624 scopus 로고    scopus 로고
    • Geometric design improvements for femoral graft-artery junctions mitigating restenosis
    • Lei M, Kleinstreuer C, Archie JP. Geometric design improvements for femoral graft-artery junctions mitigating restenosis. J Biomech 1996;29:1605-14.
    • (1996) J Biomech , vol.29 , pp. 1605-1614
    • Lei, M.1    Kleinstreuer, C.2    Archie, J.P.3
  • 5
    • 0023732723 scopus 로고
    • Arteriovenous graft life in chronic hemodialysis
    • See comment
    • Bell DB, Rosenthal JJ. Arteriovenous graft life in chronic hemodialysis. Arch Surg 1988;123:1169-1172. [See comment.]
    • (1988) Arch Surg , vol.123 , pp. 1169-1172
    • Bell, D.B.1    Rosenthal, J.J.2
  • 6
    • 0031007709 scopus 로고    scopus 로고
    • Durability of early prosthetic dialysis graft cannulation: Results of a prospective, nonrandomized clinical trial
    • Hakaim AG, Scott TE. Durability of early prosthetic dialysis graft cannulation: Results of a prospective, nonrandomized clinical trial J. Vasc Surg 1997;25:1002-6.
    • (1997) J Vasc Surg , vol.25 , pp. 1002-1006
    • Hakaim, A.G.1    Scott, T.E.2
  • 7
    • 0030199984 scopus 로고    scopus 로고
    • Effects of geometry and flow division on flow structures in models of the distal end-to-side anastomosis
    • Hughes PE, How TV. Effects of geometry and flow division on flow structures in models of the distal end-to-side anastomosis. J Biomech 1996;29:855-72.
    • (1996) J Biomech , vol.29 , pp. 855-872
    • Hughes, P.E.1    How, T.V.2
  • 8
    • 0025612052 scopus 로고
    • Does the end-to-end venous anastomosis offer a functional advantage over the end-to-side venous anastomosis in high-output arteriovenous grafts?
    • Fillinger MF, Kerns DB, Bruch D, Reinitz ER, Schwartz RA. Does the end-to-end venous anastomosis offer a functional advantage over the end-to-side venous anastomosis in high-output arteriovenous grafts? J Vase Surg 1990;12:676-88.
    • (1990) J Vase Surg , vol.12 , pp. 676-688
    • Fillinger, M.F.1    Kerns, D.B.2    Bruch, D.3    Reinitz, E.R.4    Schwartz, R.A.5
  • 9
    • 0030892898 scopus 로고    scopus 로고
    • Improved flow straighteners reduce thrombus in the NASA/DeBakey axial flow ventricular assist device
    • Kawahito K, Benkowski R, Ohtsubo S, Noon GP, Nose Y, DeBakey ME. Improved flow straighteners reduce thrombus in the NASA/DeBakey axial flow ventricular assist device. Artif Organs 1997;21:339-43.
    • (1997) Artif Organs , vol.21 , pp. 339-343
    • Kawahito, K.1    Benkowski, R.2    Ohtsubo, S.3    Noon, G.P.4    Nose, Y.5    DeBakey, M.E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.