메뉴 건너뛰기




Volumn 96, Issue 6, 2003, Pages 1636-1639

Can the bispectral index be used to predict seizure time and awakening after electroconvulsive therapy?

Author keywords

[No Author keywords available]

Indexed keywords

GLYCOPYRRONIUM BROMIDE; METHOHEXITAL;

EID: 0038700871     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/01.ANE.0000066018.13553.08     Document Type: Article
Times cited : (40)

References (14)
  • 2
    • 0031028285 scopus 로고    scopus 로고
    • Electroencephalographic bispectral index correlates with intraoperative recall and depth of propofol-induced sedation
    • Lui J, Singh H, White PF. Electroencephalographic bispectral index correlates with intraoperative recall and depth of propofol-induced sedation. Anesth Analg 1997;84:185-9.
    • (1997) Anesth Analg , vol.84 , pp. 185-189
    • Lui, J.1    Singh, H.2    White, P.F.3
  • 3
    • 0030963250 scopus 로고    scopus 로고
    • A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect
    • Sebel PS, Lang E, Rampil IJ, et al. A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect. Anesth Analg 1997;84:891-9.
    • (1997) Anesth Analg , vol.84 , pp. 891-899
    • Sebel, P.S.1    Lang, E.2    Rampil, I.J.3
  • 4
    • 0030901893 scopus 로고    scopus 로고
    • Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers
    • Glass PS, Bloom M, Kearse L, et al. Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers. Anesthesiology 1997;86:836-47.
    • (1997) Anesthesiology , vol.86 , pp. 836-847
    • Glass, P.S.1    Bloom, M.2    Kearse, L.3
  • 5
    • 0030932231 scopus 로고    scopus 로고
    • Recovery of consciousness after thiopental or propofol: Bispectral index and isolated forearm technique
    • Flaishon R, Windsor A, Sigl J, Sebel PS. Recovery of consciousness after thiopental or propofol: bispectral index and isolated forearm technique. Anesthesiology 1997;86:613-9.
    • (1997) Anesthesiology , vol.86 , pp. 613-619
    • Flaishon, R.1    Windsor, A.2    Sigl, J.3    Sebel, P.S.4
  • 6
    • 0036241723 scopus 로고    scopus 로고
    • Pre-ictal bispectral index has a positive correlation with seizure duration during etectroconvulsive therapy
    • Nishihara F, Saito S. Pre-ictal bispectral index has a positive correlation with seizure duration during etectroconvulsive therapy. Anesth Analg 2002;94:1249-52.
    • (2002) Anesth Analg , vol.94 , pp. 1249-1252
    • Nishihara, F.1    Saito, S.2
  • 7
    • 0035857782 scopus 로고    scopus 로고
    • Electroconvulsive therapy: Time to bring it out of the shadows
    • Glass RM. Electroconvulsive therapy: time to bring it out of the shadows. JAMA 2001;285:1346-8.
    • (2001) JAMA , vol.285 , pp. 1346-1348
    • Glass, R.M.1
  • 8
    • 0036236947 scopus 로고    scopus 로고
    • Anesthesia for electroconvulsive therapy
    • Ding Z, White PF. Anesthesia for electroconvulsive therapy. Anesth Analg 2002;94:1351-64.
    • (2002) Anesth Analg , vol.94 , pp. 1351-1364
    • Ding, Z.1    White, P.F.2
  • 9
    • 0026351264 scopus 로고
    • Stimulus intensity, seizure threshold, and seizure duration: Impact on the efficacy and safety of electroconvulsive therapy
    • Sackeim HA, Devanad DP, Prudic J. Stimulus intensity, seizure threshold, and seizure duration: impact on the efficacy and safety of electroconvulsive therapy. Psychiatr Clin North Am 1991;14:803-43.
    • (1991) Psychiatr Clin North Am , vol.14 , pp. 803-843
    • Sackeim, H.A.1    Devanad, D.P.2    Prudic, J.3
  • 10
    • 0030023299 scopus 로고    scopus 로고
    • Electroencephalographic bispectral analysis predicts the depth of midazolam-induced sedation
    • Liu J, Singh H, White PF. Electroencephalographic bispectral analysis predicts the depth of midazolam-induced sedation. Anesthesiology 1996;84:64-9.
    • (1996) Anesthesiology , vol.84 , pp. 64-69
    • Liu, J.1    Singh, H.2    White, P.F.3
  • 11
    • 24244460399 scopus 로고    scopus 로고
    • Does dementia affect the bispectral index?
    • Renna M, Handy J, Shah A. Does dementia affect the bispectral index [abstract]? Anesthesiology 2001;95:A286.
    • (2001) Anesthesiology , vol.95
    • Renna, M.1    Handy, J.2    Shah, A.3
  • 12
    • 0031715616 scopus 로고    scopus 로고
    • Electroconvulsive therapy decreased bispectral index: A case report
    • Tanabe T, Sakai T, Mi WD, Matsuki A. Electroconvulsive therapy decreased bispectral index: a case report. Masui 1998;47:1096-8.
    • (1998) Masui , vol.47 , pp. 1096-1098
    • Tanabe, T.1    Sakai, T.2    Mi, W.D.3    Matsuki, A.4
  • 13
    • 0036166358 scopus 로고    scopus 로고
    • Bispectral index monitoring during electroconvulsive therapy under propofol anesthesia
    • Gunawardane PO, Murphy PA, Sleigh JW. Bispectral index monitoring during electroconvulsive therapy under propofol anesthesia. Br J Anaesth 2002;88:184-7.
    • (2002) Br J Anaesth , vol.88 , pp. 184-187
    • Gunawardane, P.O.1    Murphy, P.A.2    Sleigh, J.W.3
  • 14
    • 0028353246 scopus 로고
    • Quantitative EEG correlates of cognitive deterioration in the elderly
    • Prichep LS, John ER, Ferris SH, et al. Quantitative EEG correlates of cognitive deterioration in the elderly. Neurobiol Aging 1994;15:85-90.
    • (1994) Neurobiol Aging , vol.15 , pp. 85-90
    • Prichep, L.S.1    John, E.R.2    Ferris, S.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.