메뉴 건너뛰기




Volumn 49, Issue 6, 2003, Pages 994-997

Lamellar body count in amniotic fluid: A comparative study of four different hematology analyzers

Author keywords

[No Author keywords available]

Indexed keywords

PHOSPHATIDYLCHOLINE; SPHINGOMYELIN; SURFACTANT;

EID: 0038697599     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1373/49.6.994     Document Type: Article
Times cited : (33)

References (21)
  • 1
    • 0036428016 scopus 로고    scopus 로고
    • Biogenesis of lamellar bodies: Lysosome-related organelles involved in storage and secretion of pulmonary surfactant
    • Weaver T, Na C, Stahlman M. Biogenesis of lamellar bodies: lysosome-related organelles involved in storage and secretion of pulmonary surfactant. Semin Cell Dev Biol 2002;13:263-9.
    • (2002) Semin Cell Dev Biol , vol.13 , pp. 263-269
    • Weaver, T.1    Na, C.2    Stahlman, M.3
  • 2
    • 0024544629 scopus 로고
    • Characterization of amniotic fluid lamellar bodies by resistive-pulse counting: Relationship to measures of fetal lung maturity
    • Dubin SB. Characterization of amniotic fluid lamellar bodies by resistive-pulse counting: relationship to measures of fetal lung maturity. Clin Chem 1989;35:612-6.
    • (1989) Clin Chem , vol.35 , pp. 612-616
    • Dubin, S.B.1
  • 7
    • 0028205494 scopus 로고
    • Lamellar body concentrations and the prediction of fetal pulmonary maturity
    • Fakhoury G, Daikoku NH, Benser J, Dubin NH. Lamellar body concentrations and the prediction of fetal pulmonary maturity. Am J Obstet Gynecol 1994;170:72-6.
    • (1994) Am J Obstet Gynecol , vol.170 , pp. 72-76
    • Fakhoury, G.1    Daikoku, N.H.2    Benser, J.3    Dubin, N.H.4
  • 8
    • 0028943202 scopus 로고
    • Evaluation of lamellar body number density as the initial assessment in a fetal lung maturity test cascade
    • Greenspoon JS, Rosen DJD, Roll K, Dubin SB. Evaluation of lamellar body number density as the initial assessment in a fetal lung maturity test cascade. J Reprod Med 1995;40:260-6.
    • (1995) J Reprod Med , vol.40 , pp. 260-266
    • Greenspoon, J.S.1    Rosen, D.J.D.2    Roll, K.3    Dubin, S.B.4
  • 10
    • 0030135289 scopus 로고    scopus 로고
    • Lamellar body count in amniotic fluid as a rapid screening test for fetal lung maturity
    • Lee I-S, Cho Y-K, Kim A, Min W-K, Kim K-S, Mok J-E. Lamellar body count in amniotic fluid as a rapid screening test for fetal lung maturity. J Perinatol 1996;16:176-80.
    • (1996) J Perinatol , vol.16 , pp. 176-180
    • Lee, I.-S.1    Cho, Y.-K.2    Kim, A.3    Min, W.-K.4    Kim, K.-S.5    Mok, J.-E.6
  • 11
    • 0031022061 scopus 로고    scopus 로고
    • Six alternative methods to the lecithin/sphingomyelin ratio in amniotic fluid for assessing fetal lung maturity
    • Dilena BA, Ku F, Doyle I, Whiting MJ. Six alternative methods to the lecithin/sphingomyelin ratio in amniotic fluid for assessing fetal lung maturity. Ann Clin Biochem 1997;34:106-8.
    • (1997) Ann Clin Biochem , vol.34 , pp. 106-108
    • Dilena, B.A.1    Ku, F.2    Doyle, I.3    Whiting, M.J.4
  • 13
    • 0036678046 scopus 로고    scopus 로고
    • Decreased laboratory testing for lecithin-to-sphingomyelin ratio and phosphatidylglycerol after fetal lung maturity assessment from lamellar body count in amniotic fluid
    • Ross GE, Bever FN, Uddin Z, Hockman EM, Herman BA. Decreased laboratory testing for lecithin-to-sphingomyelin ratio and phosphatidylglycerol after fetal lung maturity assessment from lamellar body count in amniotic fluid. J Am Osteopath Assoc 2002;102:423-8.
    • (2002) J Am Osteopath Assoc , vol.102 , pp. 423-428
    • Ross, G.E.1    Bever, F.N.2    Uddin, Z.3    Hockman, E.M.4    Herman, B.A.5
  • 15
    • 0025141416 scopus 로고
    • Measuring the number of lamellar body particles in amniotic fluid
    • Ashwood ER, Oldroyd RG, Palmer SE. Measuring the number of lamellar body particles in amniotic fluid. Obstet Gynecol 1990;75:289-92.
    • (1990) Obstet Gynecol , vol.75 , pp. 289-292
    • Ashwood, E.R.1    Oldroyd, R.G.2    Palmer, S.E.3
  • 16
    • 0034520776 scopus 로고    scopus 로고
    • Improved platelet counting using two-dimensional laser light scatter
    • Kunicka JE, Fischer G, Murphy J, Zelmanovic D. Improved platelet counting using two-dimensional laser light scatter. Am J Clin Pathol 2000;114:283-9.
    • (2000) Am J Clin Pathol , vol.114 , pp. 283-289
    • Kunicka, J.E.1    Fischer, G.2    Murphy, J.3    Zelmanovic, D.4
  • 17
    • 0019048010 scopus 로고
    • A side-by-side evaluation of four platelet-counting instruments
    • Dalton WT, Bollinger P, Drewinkle B. A side-by-side evaluation of four platelet-counting instruments. Am J Clin Pathol 1980;74:119-34.
    • (1980) Am J Clin Pathol , vol.74 , pp. 119-134
    • Dalton, W.T.1    Bollinger, P.2    Drewinkle, B.3
  • 18
    • 0005667021 scopus 로고    scopus 로고
    • Overview of automated hematology analyzer XE-2100
    • Inoue H. Overview of automated hematology analyzer XE-2100. Sysmex J Int 1999;9:58-65.
    • (1999) Sysmex J Int , vol.9 , pp. 58-65
    • Inoue, H.1
  • 20
    • 0036185495 scopus 로고    scopus 로고
    • Reference intervals for a complete blood count determined on different automated haematology analyzers: Abx Pentra 120 Retic, Coulter Gen-S, Sysmex SE 9500, Abbott Cell Dyn 4000, and Bayer ADVIA 120
    • Van den Bossche J, Devreese K, Malfait R, Van de Vyvere M, Wauters A, Neels H, et al. Reference intervals for a complete blood count determined on different automated haematology analyzers: Abx Pentra 120 Retic, Coulter Gen-S, Sysmex SE 9500, Abbott Cell Dyn 4000, and Bayer ADVIA 120. Clin Chem Lab Med 2002;40:69-73.
    • (2002) Clin Chem Lab Med , vol.40 , pp. 69-73
    • Van Den Bossche, J.1    Devreese, K.2    Malfait, R.3    Van De Vyvere, M.4    Wauters, A.5    Neels, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.