메뉴 건너뛰기




Volumn 67, Issue 3-4, 2003, Pages 593-598

Electron energy device for process control

Author keywords

Beam energy; Charge deposition; Electron beam; Electron energy; Electron processing; Process control

Indexed keywords

ALUMINUM; ELECTRON BEAMS; PROCESS CONTROL; RADIATION CHEMISTRY;

EID: 0038695878     PISSN: 0969806X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-806X(03)00111-7     Document Type: Conference Paper
Times cited : (20)

References (9)
  • 1
    • 85031173215 scopus 로고    scopus 로고
    • Andreo, P., Ito, R., Tabata, T., 1992. Tables of charge- and energy-deposition distributions in elemental materials irradiated by plane-parallel electron beams with energies between 0.1 and 100 MeV, Report ISSN 0917-8015, Research Institute of Advanced Science and Technology, University of Osaka Pref., Japan
    • Andreo, P., Ito, R., Tabata, T., 1992. Tables of charge- and energy-deposition distributions in elemental materials irradiated by plane-parallel electron beams with energies between 0.1 and 100 MeV, Report ISSN 0917-8015, Research Institute of Advanced Science and Technology, University of Osaka Pref., Japan.
  • 2
    • 85031163380 scopus 로고    scopus 로고
    • ASTM, 2002a. Standard practice for dosimetry in an electron-beam facility for radiation processing at energies between 300 keV and 25 MeV, ISO/ASTM 51649, Annual Book of ASTM Standards 12.02, Philadelphia, PA
    • ASTM, 2002a. Standard practice for dosimetry in an electron-beam facility for radiation processing at energies between 300 keV and 25 MeV, ISO/ASTM 51649, Annual Book of ASTM Standards 12.02, Philadelphia, PA.
  • 3
    • 85031163891 scopus 로고    scopus 로고
    • ASTM, 2002b. Standard practice for dosimetry in electron and bremsstrahlung irradiation facilities for food processing, ISO/ASTM 51431, Annual Book of ASTM Standards 12.02, Philadelphia, PA
    • ASTM, 2002b. Standard practice for dosimetry in electron and bremsstrahlung irradiation facilities for food processing, ISO/ASTM 51431, Annual Book of ASTM Standards 12.02, Philadelphia, PA.
  • 4
    • 0024993051 scopus 로고
    • An energy monitor for electron accelerators
    • Geske G. An energy monitor for electron accelerators. Strahlenther. Onkol. 166:1990;610-616.
    • (1990) Strahlenther. Onkol. , vol.166 , pp. 610-616
    • Geske, G.1
  • 5
    • 85031163318 scopus 로고    scopus 로고
    • ICRU, 1984. Radiation dosimetry: electron beams with energy between 1 and 50 MeV, Report No. 35. International Commission on Radiation Units and Measurements, Bethesda, MD, USA
    • ICRU, 1984. Radiation dosimetry: electron beams with energy between 1 and 50 MeV, Report No. 35. International Commission on Radiation Units and Measurements, Bethesda, MD, USA.
  • 6
    • 0022618202 scopus 로고
    • Using ion chambers with wedge-shaped absorbers for electron energy measurements
    • Johnsen S.W. Using ion chambers with wedge-shaped absorbers for electron energy measurements. Med. Phys. 37(2):1986;257-258.
    • (1986) Med. Phys. , vol.37 , Issue.2 , pp. 257-258
    • Johnsen, S.W.1
  • 8
    • 85031171190 scopus 로고    scopus 로고
    • Mehta, K., Barnard, J., Stanley, W., Unger, A., 1991. Experience with e-beam process dosimetry at the Whiteshell Irradiator. In: Proceedings of the International Symposium on High Dose Dosimetry for Radiation Processing. International Atomic Energy Agency, Vienna, Austria, 5-9 November 1990, pp. 451-458
    • Mehta, K., Barnard, J., Stanley, W., Unger, A., 1991. Experience with e-beam process dosimetry at the Whiteshell Irradiator. In: Proceedings of the International Symposium on High Dose Dosimetry for Radiation Processing. International Atomic Energy Agency, Vienna, Austria, 5-9 November 1990, pp. 451-458.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.