메뉴 건너뛰기




Volumn 4, Issue 3, 2003, Pages 213-218

Comparison of the NovaSom QCG™, a new sleep apnea home-diagnostic system, and polysomnography

Author keywords

Diagnosis; Home monitoring; Obstructive sleep apnea; Polysomnography; Self administered; Three nights; Unattended

Indexed keywords

ADULT; AGED; ARTICLE; CONTROLLED STUDY; CORRELATION ANALYSIS; DIAGNOSTIC TEST; FEMALE; GEOGRAPHY; HUMAN; INTERMETHOD COMPARISON; LABORATORY TEST; MAJOR CLINICAL STUDY; MALE; MEDICAL DOCUMENTATION; MEDICAL INSTRUMENTATION; NIGHT; PATIENT REFERRAL; POLYSOMNOGRAPHY; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; SLEEP APNEA SYNDROME; TIME; AMBULATORY MONITORING; CLINICAL TRIAL; COMPARATIVE STUDY; INSTRUMENTATION; MIDDLE AGED; REPRODUCIBILITY; SELF CARE; STANDARD;

EID: 0038676948     PISSN: 13899457     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1389-9457(02)00234-4     Document Type: Article
Times cited : (70)

References (30)
  • 1
    • 0027462562 scopus 로고
    • The occurrence of sleep-disordered breathing among middle-aged adults
    • Young T, Palta M, Dempsey J, et al. The occurrence of sleep-disordered breathing among middle-aged adults. N Engl J Med 1993; 328(17):1230-5.
    • (1993) N. Engl. J. Med. , vol.328 , Issue.17 , pp. 1230-1235
    • Young, T.1    Palta, M.2    Dempsey, J.3
  • 2
    • 0034192598 scopus 로고    scopus 로고
    • Sleepiness-related accidents in sleep apnea patients
    • Horstmann S, Hess CW, Bassetti C, et al. Sleepiness-related accidents in sleep apnea patients. Sleep 2000;23(3):383-9.
    • (2000) Sleep , vol.23 , Issue.3 , pp. 383-389
    • Horstmann, S.1    Hess, C.W.2    Bassetti, C.3
  • 3
    • 0035253281 scopus 로고    scopus 로고
    • The association of sleep-disordered breathing and sleep symptoms with quality of life in the Sleep Heart Health Study
    • Baldwin CM, Griffith KA, Nieto FJ, et al. The association of sleep-disordered breathing and sleep symptoms with quality of life in the Sleep Heart Health Study. Sleep 2001;24(1):96-105.
    • (2001) Sleep , vol.24 , Issue.1 , pp. 96-105
    • Baldwin, C.M.1    Griffith, K.A.2    Nieto, F.J.3
  • 4
    • 0030423677 scopus 로고    scopus 로고
    • Snoring as part of a dose-response relationship between sleep-disordered breathing and blood pressure
    • Young T, Finn L, Hla KM, et al. Snoring as part of a dose-response relationship between sleep-disordered breathing and blood pressure. Sleep 1996;10(Suppl):S202-5.
    • (1996) Sleep , vol.10 , Issue.SUPPL.
    • Young, T.1    Finn, L.2    Hla, K.M.3
  • 5
    • 23444451111 scopus 로고
    • Sleep apnea and hypertension. A population-based study
    • Hla KM, Young TB, Bidwell T, et al. Sleep apnea and hypertension. A population-based study. Ann Intern Med 1994;120(5):382-8.
    • (1994) Ann. Intern. Med. , vol.120 , Issue.5 , pp. 382-388
    • Hla, K.M.1    Young, T.B.2    Bidwell, T.3
  • 6
    • 0034685268 scopus 로고    scopus 로고
    • Obstructive sleep apnoea syndrome as a risk factor for hypertension: Population study
    • (7233)
    • Lavie P, Herer P, Hoffstein V. Obstructive sleep apnoea syndrome as a risk factor for hypertension: population study. Br Med J 2000; 320(7233):479-82.
    • (2000) Br. Med. J. , vol.320 , pp. 479-482
    • Lavie, P.1    Herer, P.2    Hoffstein, V.3
  • 7
    • 0026887059 scopus 로고
    • Snoring, sleep apnea syndrome, and stroke
    • Palomaki H, Partinen M, Erkinjuntti T, et al. Snoring, sleep apnea syndrome, and stroke. Neurology 1992;42(7 Suppl 6):75-81.
    • (1992) Neurology , vol.42 , Issue.7 SUPPL. 6 , pp. 75-81
    • Palomaki, H.1    Partinen, M.2    Erkinjuntti, T.3
  • 8
    • 0029950366 scopus 로고    scopus 로고
    • Sleep apnea in patients with transient ischemic attack and stroke: A prospective study of 59 patients
    • Bassetti C, Aldrich MS, Chervin RD, et al. Sleep apnea in patients with transient ischemic attack and stroke: a prospective study of 59 patients. Neurology 1996;47(5):1167-73.
    • (1996) Neurology , vol.47 , Issue.5 , pp. 1167-1173
    • Bassetti, C.1    Aldrich, M.S.2    Chervin, R.D.3
  • 9
    • 0034671238 scopus 로고    scopus 로고
    • Cost justification for diagnosis and treatment of obstructive sleep apnea. Position statement of the American Academy of Sleep Medicine
    • Anonymous
    • Anonymous, Cost justification for diagnosis and treatment of obstructive sleep apnea. Position statement of the American Academy of Sleep Medicine. Sleep 2000;23(8):1017.
    • (2000) Sleep , vol.23 , Issue.8 , pp. 1017
  • 10
    • 0033559477 scopus 로고    scopus 로고
    • Health care utilization in the 10 years prior to diagnosis in obstructive sleep apnea syndrome patients
    • Ronald J, Delaive K, Roos L, et al. Health care utilization in the 10 years prior to diagnosis in obstructive sleep apnea syndrome patients. Sleep 1999;22(2):225-9.
    • (1999) Sleep , vol.22 , Issue.2 , pp. 225-229
    • Ronald, J.1    Delaive, K.2    Roos, L.3
  • 11
    • 0033568054 scopus 로고    scopus 로고
    • The medical cost of undiagnosed sleep apnea
    • Kapur V, Blough D, Sandblom R, et al. The medical cost of undiagnosed sleep apnea. Sleep 1999;22(6):749-55.
    • (1999) Sleep , vol.22 , Issue.6 , pp. 749-755
    • Kapur, V.1    Blough, D.2    Sandblom, R.3
  • 12
    • 0034834110 scopus 로고    scopus 로고
    • Influence of setting on unattended respiratory monitoring in the sleep apnoea/hypopnea syndrome
    • Lloberes P, Sampol G, Levy G, et al. Influence of setting on unattended respiratory monitoring in the sleep apnoea/hypopnea syndrome. Eur Respir J 2001;18:530-4.
    • (2001) Eur. Respir. J. , vol.18 , pp. 530-534
    • Lloberes, P.1    Sampol, G.2    Levy, G.3
  • 13
    • 0021715051 scopus 로고
    • Measurement error in visually scored electrophysiological data: Respiration during sleep
    • Bliwise D, Bliwise N, Kraimer H, et al. Measurement error in visually scored electrophysiological data: respiration during sleep. J Neurosci Methods 1984;12:49-56.
    • (1984) J. Neurosci. Methods , vol.12 , pp. 49-56
    • Bliwise, D.1    Bliwise, N.2    Kraimer, H.3
  • 14
    • 0036179246 scopus 로고    scopus 로고
    • Scoring variability between polysomnography technologists in different sleep laboratories
    • Collop N. Scoring variability between polysomnography technologists in different sleep laboratories. Sleep Med 2002;3:43-7.
    • (2002) Sleep Med. , vol.3 , pp. 43-47
    • Collop, N.1
  • 15
    • 0033900093 scopus 로고    scopus 로고
    • Mild to moderate sleep respiratory events - One night may not be enough
    • Le Bon O, Hoffmann G, Tecco J, et al. Mild to moderate sleep respiratory events - one night may not be enough. Chest 2000;118: 353-9.
    • (2000) Chest , vol.118 , pp. 353-359
    • Le Bon, O.1    Hoffmann, G.2    Tecco, J.3
  • 16
    • 0029741382 scopus 로고    scopus 로고
    • The effect of polysomnography on sleep position: Possible implications on the diagnosis of positional obstructive sleep apnea
    • Metersky M, Castriotta R. The effect of polysomnography on sleep position: possible implications on the diagnosis of positional obstructive sleep apnea. Respiration 1996;63(5):283-7.
    • (1996) Respiration , vol.63 , Issue.5 , pp. 283-287
    • Metersky, M.1    Castriotta, R.2
  • 17
    • 0038129011 scopus 로고    scopus 로고
    • A quantitative assessment of sleep laboratory activity in the United States
    • Tachibana N, Ayas N, White D. A quantitative assessment of sleep laboratory activity in the United States. AASM Bull 2002;9(2):26-8.
    • (2002) AASM Bull. , vol.9 , Issue.2 , pp. 26-28
    • Tachibana, N.1    Ayas, N.2    White, D.3
  • 18
    • 0029149843 scopus 로고
    • Validation of a portable sleep apnea monitoring device
    • Man G, Kang B. Validation of a portable sleep apnea monitoring device. Chest 1995;108:388-93.
    • (1995) Chest , vol.108 , pp. 388-393
    • Man, G.1    Kang, B.2
  • 19
    • 0032906570 scopus 로고    scopus 로고
    • Portable computerized polysomnography in attended and unattended settings
    • Mykytyn I, Sajkov D, Neill A, et al. Portable computerized polysomnography in attended and unattended settings. Chest 1999; 115:114-22.
    • (1999) Chest , vol.115 , pp. 114-122
    • Mykytyn, I.1    Sajkov, D.2    Neill, A.3
  • 20
    • 0034097857 scopus 로고    scopus 로고
    • Validation of the POLY-MESAM seven-channel ambulatory recording unit
    • Verse T, Pirsig W, Jung-Hulsing B, et al. Validation of the POLY-MESAM seven-channel ambulatory recording unit. Chest 2000; 117(6):1613-8.
    • (2000) Chest , vol.117 , Issue.6 , pp. 1613-1618
    • Verse, T.1    Pirsig, W.2    Jung-Hulsing, B.3
  • 21
    • 0035459274 scopus 로고    scopus 로고
    • Clinical validation of the bedbug in detection of obstructive sleep apnea
    • Claman D, Murr A, Trotter K. Clinical validation of the bedbug in detection of obstructive sleep apnea. Otolaryngol Head Neck Surg 2001;125:227-30.
    • (2001) Otolaryngol. Head Neck Surg. , vol.125 , pp. 227-230
    • Claman, D.1    Murr, A.2    Trotter, K.3
  • 22
    • 0343362699 scopus 로고    scopus 로고
    • Association of sleep-disordered breathing, sleep apnea, and hypertension in a large community-based study
    • Nieto F, Young T, Lind B, et al. Association of sleep-disordered breathing, sleep apnea, and hypertension in a large community-based study. J Am Med Assoc 2000;283(14):1829-36.
    • (2000) J. Am. Med. Assoc. , vol.283 , Issue.14 , pp. 1829-1836
    • Nieto, F.1    Young, T.2    Lind, B.3
  • 23
    • 0033825836 scopus 로고    scopus 로고
    • Evaluation of home versus laboratory polysomnography in the diagnosis of sleep apnea syndrome
    • Portier F, Portmann A, Szernichow P, et al. Evaluation of home versus laboratory polysomnography in the diagnosis of sleep apnea syndrome. Am J Respir Crit Care Med 2000;162:814-8.
    • (2000) Am. J. Respir. Crit. Care Med. , vol.162 , pp. 814-818
    • Portier, F.1    Portmann, A.2    Szernichow, P.3
  • 24
    • 0030924534 scopus 로고    scopus 로고
    • Practice parameters for the indications of polysomnography and related procedures
    • American Sleep Disorders Association Standards of Practice Committee
    • American Sleep Disorders Association Standards of Practice Committee, Practice parameters for the indications of polysomnography and related procedures. Sleep 1997;20(6):406-22.
    • (1997) Sleep , vol.20 , Issue.6 , pp. 406-422
  • 25
    • 0034014539 scopus 로고    scopus 로고
    • Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea
    • Vazquez J, Tsai W, Flemons W, et al. Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea. Thorax 2000; 55:302-7.
    • (2000) Thorax , vol.55 , pp. 302-307
    • Vazquez, J.1    Tsai, W.2    Flemons, W.3
  • 26
    • 0034038095 scopus 로고    scopus 로고
    • Split-night versus full-night studies for sleep apnoea/hypopnoea syndrome
    • McArdle N, Grove A, Devereux G, et al. Split-night versus full-night studies for sleep apnoea/hypopnoea syndrome. Eur Respir J 2000;4: 670-5.
    • (2000) Eur. Respir. J. , vol.4 , pp. 670-675
    • McArdle, N.1    Grove, A.2    Devereux, G.3
  • 27
    • 0003409637 scopus 로고
    • A manual of standardized terminology and scoring system for sleep stages of human subjects
    • editors. Los Angeles, CA: Brain Information Services/Brain Research Institute, University of California at Los Angeles
    • Rechtschaffen A, Kales A, editors. A manual of standardized terminology and scoring system for sleep stages of human subjects. Los Angeles, CA: Brain Information Services/Brain Research Institute, University of California at Los Angeles; 1968.
    • (1968)
    • Rechtschaffen, A.1    Kales, A.2
  • 28
    • 0017360990 scopus 로고    scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis J, Koch G. The measurement of observer agreement for categorical data. Biometrics 1997;33:159-74.
    • (1997) Biometrics , vol.33 , pp. 159-174
    • Landis, J.1    Koch, G.2
  • 29
    • 0027403440 scopus 로고
    • One negative polysomnogram does not exclude obstructive sleep apnea
    • Meyer T, Eveloff S, Kline L, et al. One negative polysomnogram does not exclude obstructive sleep apnea. Chest 1993;103:756-60.
    • (1993) Chest , vol.103 , pp. 756-760
    • Meyer, T.1    Eveloff, S.2    Kline, L.3
  • 30
    • 0028967543 scopus 로고
    • Assessment of accuracy and analysis time of a novel device to monitor sleep and breathing in the home
    • White D, Gibb T, Wall J, et al. Assessment of accuracy and analysis time of a novel device to monitor sleep and breathing in the home. Sleep 1995;18(2):115-26.
    • (1995) Sleep , vol.18 , Issue.2 , pp. 115-126
    • White, D.1    Gibb, T.2    Wall, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.