메뉴 건너뛰기




Volumn 1, Issue ASIA PACIFIC, 2002, Pages 118-123

Investigation of practical problems for digital fault location algorithms based on EMTP simulation

Author keywords

ATP; Digital protection; Fault location; Mutual coupling; Transmission line

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; COUPLED CIRCUITS; DIGITAL SIGNAL PROCESSING; DISCRETE FOURIER TRANSFORMS; ELECTRIC FAULT CURRENTS; ELECTRIC POWER TRANSMISSION; ELECTROMAGNETIC WAVE PROPAGATION;

EID: 0038648322     PISSN: 21608555     EISSN: 21608563     Source Type: Journal    
DOI: 10.1109/TDC.2002.1178270     Document Type: Article
Times cited : (21)

References (28)
  • 1
    • 85095912894 scopus 로고
    • High speed relaying using travelling wave transient analysis
    • New York, Jan. 29-Feb. 3
    • H. W. Dommel and J. M. Michels, “High Speed Relaying Using Travelling Wave Transient Analysis”, IEEE PES Winter Power Meeting, New York, Jan. 29-Feb. 3, 1978, pp 1-7.
    • (1978) IEEE PES Winter Power Meeting , pp. 1-7
    • Dommel, H.W.1    Michels, J.M.2
  • 2
    • 84954434609 scopus 로고    scopus 로고
    • Fault location on a transmission line using high frequency travelling waves measured at a single line end
    • IEEE
    • M. Aurangzeb, P. A. Crossley and P. Gale, “Fault location on a transmission line using high frequency travelling waves measured at a single line end”, PES Winter Power Meeting, 2000. IEEE, Vol. 4, 2000, pp. 2437-2442.
    • (2000) PES Winter Power Meeting, 2000 , vol.4 , pp. 2437-2442
    • Aurangzeb, M.1    Crossley, P.A.2    Gale, P.3
  • 7
    • 0026897098 scopus 로고
    • Effects of frequency dependence and line parameters on single ended travelling wave based fault location schemes
    • G.B.Ancell, N.C. Pahalawaththa. “Effects of frequency dependence and line parameters on single ended travelling wave based fault location schemes”, IEE Proceedings C, Vol. 139, 1992, pp. 332-342.
    • (1992) IEE Proceedings C , vol.139 , pp. 332-342
    • Ancell, G.B.1    Pahalawaththa, N.C.2
  • 8
    • 0018545920 scopus 로고
    • On line digital fault locator for overhead transmission line
    • M. T. Sant, M. Tech and Y. G. Paithankar, “On line digital fault locator for overhead transmission line”, IEE proceedings. Vol. 126, 1979, pp. 1181-1185.
    • (1979) IEE Proceedings , vol.126 , pp. 1181-1185
    • Sant, M.T.1    Tech, M.2    Paithankar, Y.G.3
  • 10
    • 85013567034 scopus 로고    scopus 로고
    • A new algorithm for EHV/UHV transmission lines: Part-II Laplace transform method
    • T. Takagi, Y. Yamakoshi, J. Baba, K. Uemura and T. Sakaguchi. “a new algorithm for EHV/UHV transmission lines: Part-II Laplace transform method”, IEEE PES Summer Meeting 81, SM 411-8.
    • IEEE PES Summer Meeting , vol.81 , pp. SM411-418
    • Takagi, T.1    Yamakoshi, Y.2    Baba, J.3    Uemura, K.4    Sakaguchi, T.5
  • 12
    • 0038781352 scopus 로고
    • Acuurate fault impedance locating algorithm
    • A. Wiszniewski, “Acuurate fault impedance locating algorithm”, IEE Proceedings, Vol. 130, Pt. C, 1993, pp.331-314.
    • (1993) IEE Proceedings , vol.130 , pp. 331-314
    • Wiszniewski, A.1
  • 13
    • 0022010176 scopus 로고
    • An accurate fault locator with compensation for apparent reactance in the fault resistance resulting from remote end infeed
    • Feb
    • L. Eriksson, M. Saha and G. D. Rockefeller, “An accurate fault locator with compensation for apparent reactance in the fault resistance resulting from remote end infeed”, IEEE Trans. on Power Apparatus and Systems, Vol. PAS-104, NO. 2, Feb. 1985, pp. 424-436.
    • (1985) IEEE Trans. on Power Apparatus and Systems , vol.PAS-104 , Issue.2 , pp. 424-436
    • Eriksson, L.1    Saha, M.2    Rockefeller, G.D.3
  • 14
    • 0023290461 scopus 로고
    • Application of adaptive Kalman filtering in fault classification, distance protection and fault location using microprocessors
    • Feb
    • A. Girgis and E. Makram, “Application of adaptive Kalman filtering in fault classification, distance protection and fault location using microprocessors”, IEEE Trans. on Power Systems, Vol. 3, No. 1, Feb. 1988, pp. 301-309.
    • (1988) IEEE Trans. on Power Systems , vol.3 , Issue.1 , pp. 301-309
    • Girgis, A.1    Makram, E.2
  • 15
    • 0001737930 scopus 로고
    • Fundamental aspects of fault location algorithms used in distance protection
    • V. Cook, “Fundamental aspects of fault location algorithms used in distance protection”, IEE Proceedings, Vol. 133 Pt. C, 1986, pp.359-366.
    • (1986) IEE Proceedings , vol.133 , pp. 359-366
    • Cook, V.1
  • 16
    • 0025517399 scopus 로고
    • Accurate fault location technique for power transmission lines
    • Pt. C
    • A. T. Johns, S. Jamali, “Accurate fault location technique for power transmission lines”, IEE Proceedings, Vol. 137 Pt. C, NO. 6 1990, pp. 395-402.
    • (1990) IEE Proceedings , vol.137 , Issue.6 , pp. 395-402
    • Johns, A.T.1    Jamali, S.2
  • 17
    • 0038443524 scopus 로고
    • Accurate fault location of transmission lines using microprocessors
    • developments in power system
    • B. Jeyasura and M. A. Rahman, “Accurate fault location of transmission lines using microprocessors”, developments in power system protection, 1988, Forth International Conference, pp. 13-17.
    • (1988) Forth International Conference Protection , pp. 13-17
    • Jeyasura, B.1    Rahman, M.A.2
  • 18
    • 0023844294 scopus 로고
    • A technique for estimating line fault locations from digital impedance relay measurements
    • Jan
    • M. S. Sachdev and R. Agarwal, “A technique for estimating line fault locations from digital impedance relay measurements”, IEEE Trans. on Power Delivery, Vol. 3, No. 1, Jan. 1988, pp. 121-129.
    • (1988) IEEE Trans. on Power Delivery , vol.3 , Issue.1 , pp. 121-129
    • Sachdev, M.S.1    Agarwal, R.2
  • 19
    • 0026623757 scopus 로고
    • A new fault location technique for two and three terminal lines
    • Jan
    • A. Girgis, d. Hart, W. Peterson, “A new fault location technique for two and three terminal lines”, IEEE Trans. on Power Delivery, Vol. 7. No. 1. Jan. 1992, pp. 98-107.
    • (1992) IEEE Trans. on Power Delivery , vol.7 , Issue.1 , pp. 98-107
    • Girgis, A.1    Hart, D.2    Peterson, W.3
  • 20
    • 0029736561 scopus 로고    scopus 로고
    • Unsynchronized two-terminal fault location estimation
    • Jan
    • D. Novosel, D. Hart, E. Udren and J. Garitty, “Unsynchronized two-terminal fault location estimation”, IEEE Trans. on Power Delivery, Vol. 11. No. 1, Jan. 1996, pp. 130-138.
    • (1996) IEEE Trans. on Power Delivery , vol.11 , Issue.1 , pp. 130-138
    • Novosel, D.1    Hart, D.2    Udren, E.3    Garitty, J.4
  • 21
    • 0034171499 scopus 로고    scopus 로고
    • An adaptive PMU based fault detection/location technique for transmission lines. P. I: Theory and algorithms
    • Jan
    • J. Jiang, J. Yang, Y. Lin, C. Liu and J. Ma, “An adaptive PMU based fault detection/location technique for transmission lines. P. I: Theory and algorithms”, IEEE Trans. on Power Delivery, Vol. 15, No. 2, Jan. 2000, pp.486-493.
    • (2000) IEEE Trans. on Power Delivery , vol.15 , Issue.2 , pp. 486-493
    • Jiang, J.1    Yang, J.2    Lin, Y.3    Liu, C.4    Ma, J.5
  • 22
    • 0034171499 scopus 로고    scopus 로고
    • An adaptive PMU based fault detection/location technique for transmission lines. P. I: Theory and algorithms
    • Oct
    • J. Jiang, J. Yang, Y. Lin, C. Liu and J. Ma, “An adaptive PMU based fault detection/location technique for transmission lines. P. I: Theory and algorithms”, IEEE Trans. on Power Delivery, Vol. 15, No. 4, Oct. 2000, pp. 1136-146.
    • (2000) IEEE Trans. on Power Delivery , vol.15 , Issue.4 , pp. 1136-1146
    • Jiang, J.1    Yang, J.2    Lin, Y.3    Liu, C.4    Ma, J.5
  • 23
    • 85013608169 scopus 로고    scopus 로고
    • Leuven EMTP Center (LEG), Alternative Transient Program, ATP, Rule Book, 1987
    • Leuven EMTP Center (LEG), Alternative Transient Program, ATP, Rule Book, 1987.
  • 24
    • 0026939751 scopus 로고
    • Development of an advanced transmission line fault location system, Part II-Algorithm development and simulation
    • Oct
    • D. Lawrence, L. Cabeza and L. Hochberg, “Development of an advanced transmission line fault location system, Part II-Algorithm development and simulation”, IEEE Trans. on Power Delivery, Vol. 7, No. 4, Oct. 1992, pp. 1972-1983.
    • (1992) IEEE Trans. on Power Delivery , vol.7 , Issue.4 , pp. 1972-1983
    • Lawrence, D.1    Cabeza, L.2    Hochberg, L.3
  • 27
    • 0038781356 scopus 로고    scopus 로고
    • Distance protection relay for transmission lines, 7SA522: User catalog
    • Siemens AG
    • Siemens, “Distance protection relay for Transmission lines, 7SA522: User Catalog”, Catalog SIP 4.2, Siemens AG 1999.
    • (1999) Catalog SIP 4.2
  • 28
    • 0035481805 scopus 로고    scopus 로고
    • A new transmission line fault locating system
    • Oct
    • T. Adu, “A new Transmission Line Fault Locating System”, IEEE Trans. on Power Delivery, Vol. 16, No. 4, Oct. 2001, pp. 498-503.
    • (2001) IEEE Trans. on Power Delivery , vol.16 , Issue.4 , pp. 498-503
    • Adu, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.