메뉴 건너뛰기




Volumn 44, Issue 3, 2003, Pages 340-342

A modified sonographic technique for assessment of gastric emptying of liquid

Author keywords

Gastric emptying; Sonography

Indexed keywords

ADULT; ARTICLE; ECHOGRAPHY; FEMALE; HUMAN; MALE; OBSERVER VARIATION; PHYSIOLOGY; STOMACH; STOMACH ANTRUM; STOMACH EMPTYING;

EID: 0038626560     PISSN: 02841851     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1600-0455.2003.00055.x     Document Type: Article
Times cited : (11)

References (12)
  • 2
    • 0020027184 scopus 로고
    • Measurement of gastric emptying by real‐time ultrasound
    • 2 Bateman DN, Whittingham TA. Measurement of gastric emptying by real‐time ultrasound. Gut 1982 ; 23: 524–7.
    • (1982) Gut , vol.23 , pp. 524-7
    • Bateman, DN1    Whittingham, TA.2
  • 4
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • 4 Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986 ; i: 307–10.
    • (1986) Lancet , vol.i , pp. 307-10
    • Bland, JM1    Altman, DG.2
  • 6
    • 0022553878 scopus 로고
    • Variability of gastric emptying measurements in man employing standardized radiolabeled meals
    • 6 Brophy CM, Moore JG, Christian PE, Egger MJ, Taylor AT. Variability of gastric emptying measurements in man employing standardized radiolabeled meals. Dig. Dis. Sci. 1986 ; 31: 799–806.
    • (1986) Dig. Dis. Sci. , vol.31 , pp. 799-806
    • Brophy, CM1    Moore, JG2    Christian, PE3    Egger, MJ4    Taylor, AT.5
  • 7
    • 0021090459 scopus 로고
    • Gastric emptying in normal subjects – a reproducible technique using a single scintillation camera and computer system
    • 7 Collins PJ, Horowitz M, Cook DJ, Harding PE, Shearman DJC. Gastric emptying in normal subjects–a reproducible technique using a single scintillation camera and computer system. Gut 1983 ; 24: 1117–25.
    • (1983) Gut , vol.24 , pp. 1117-25
    • Collins, PJ1    Horowitz, M2    Cook, DJ3    Harding, PE4    Shearman, DJC.5
  • 8
    • 0022642198 scopus 로고
    • Measurement of gastric emptying rate in humans by real‐time ultrasound
    • 8 Holt S, Cervantes J, Wilkinson AA, Wallace JHK. Measurement of gastric emptying rate in humans by real‐time ultrasound. Gastroenterology 1986 ; 90: 918–23.
    • (1986) Gastroenterology , vol.90 , pp. 918-23
    • Holt, S1    Cervantes, J2    Wilkinson, AA3    Wallace, JHK.4
  • 9
    • 0030016325 scopus 로고    scopus 로고
    • Scintigraphic measurement of gastric emptying and ultrasonographic assessment of antral area: relation to appetite
    • 9 Hveem K, Jones KL, Chatterton BE, Horowitz M. Scintigraphic measurement of gastric emptying and ultrasonographic assessment of antral area: relation to appetite. Gut 1996 ; 38: 816–21.
    • (1996) Gut , vol.38 , pp. 816-21
    • Hveem, K1    Jones, KL2    Chatterton, BE3    Horowitz, M.4
  • 10
    • 0027285018 scopus 로고
    • Reliability and interobserver variability of ultrasonographic measurement of gastric emptying rate
    • 10 Irvine EJ, Tougas G, Lappalainen R, Bathurst NC. Reliability and interobserver variability of ultrasonographic measurement of gastric emptying rate. Dig. Dis. Sci. 1993 ; 38: 803–10.
    • (1993) Dig. Dis. Sci. , vol.38 , pp. 803-10
    • Irvine, EJ1    Tougas, G2    Lappalainen, R3
  • 11
    • 0034106865 scopus 로고    scopus 로고
    • Standards for diagnosis of gastrointestinal motility disorders. Section: ultrasonography. A position statement from the Gruppo Italiano di Studio Mobilità Apparato Digerente (GISMAD)
    • 11 Portincasa P, Colecchia A, DiCiaula A et al. Standards for diagnosis of gastrointestinal motility disorders. Section: ultrasonography. A position statement from the Gruppo Italiano di Studio Mobilità Apparato Digerente (GISMAD). Dig. Liver Dis. 2000 ; 32: 160–72.
    • (2000) Dig. Liver Dis. , vol.32 , pp. 160-72
    • Portincasa, P1    Colecchia, A2    DiCiaula, A3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.