메뉴 건너뛰기




Volumn 90, Issue 4, 2003, Pages 357-362

Accuracy of intraoperative frozen section diagnosis in non palpable breast lesions: A series of 791 cases;Efficacité de l'examen peropératoire des lésions infracliniques mammaires: Étude sur une série de 791 cas

Author keywords

Breast lesion; Intraoperative frozen section; Mammography

Indexed keywords

ARTICLE; BREAST CALCIFICATION; BREAST CARCINOMA; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FROZEN SECTION; HUMAN; HUMAN TISSUE; INTERMETHOD COMPARISON; LABORATORY DIAGNOSIS; MAJOR CLINICAL STUDY; MAMMOGRAPHY; RELIABILITY; SENSITIVITY AND SPECIFICITY; TISSUE SECTION; BREAST; BREAST TUMOR; DIFFERENTIAL DIAGNOSIS; FEMALE; PAGET NIPPLE DISEASE; PATHOLOGY; RADIOGRAPHY; REPRODUCIBILITY;

EID: 0038579347     PISSN: 00074551     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (9)
  • 1
    • 0027296952 scopus 로고
    • Association of directors of anatomic and surgical pathology
    • ADASP. Am J Surg Pathol 1993 ; 17 : 850-1.
    • (1993) Am J Surg Pathol , vol.17 , pp. 850-851
  • 2
    • 0029177011 scopus 로고
    • Contrôle de qualité en anatomo-cyto-pathologie. Cancer du sein. Rapport de Haut comité de la santé publique
    • Vacher-Lavenu MC. Contrôle de qualité en anatomo-cyto-pathologie. Cancer du sein. Rapport de Haut comité de la santé publique. Arch Anatom Cytol Pathol 1995 ; 43 : 101-6.
    • (1995) Arch Anatom Cytol Pathol , vol.43 , pp. 101-106
    • Vacher-Lavenu, M.C.1
  • 3
    • 0001186351 scopus 로고    scopus 로고
    • Rapport des anatomo-pathologistes de l'union européenne
    • Rapport des anatomo-pathologistes de l'union européenne. Ann Pathol 1996 ; 16 : 315-33.
    • (1996) Ann Pathol , vol.16 , pp. 315-333
  • 4
    • 0038589691 scopus 로고    scopus 로고
    • Examens anatomo-pathologiques extemporanés dans les pathologies mammaires et thyroïdiennes
    • Agence nationale d'accréditation et d'évaluation en santé. Examens anatomo-pathologiques extemporanés dans les pathologies mammaires et thyroïdiennes. Ann Oto-rhino-laryngol Chir Cervico-faciale 1998 ; 115 : 46-74.
    • (1998) Ann Oto-rhino-laryngol Chir Cervico-faciale , vol.115 , pp. 46-74
  • 6
    • 0023488497 scopus 로고
    • Mammographic and histopathologic correlation of nonpalpable lesions of the breast and the reliability of frozen section diagnosis
    • Tinnemans JGM. Mammographic and histopathologic correlation of nonpalpable lesions of the breast and the reliability of frozen section diagnosis. Surg Gynecol Obstetrics 1987 ; 165 : 523-9.
    • (1987) Surg Gynecol Obstetrics , vol.165 , pp. 523-529
    • Tinnemans, J.G.M.1
  • 8
    • 0025266965 scopus 로고
    • The reliability of frozen section diagnosis
    • Torp SH, Skjorten FJ. The reliability of frozen section diagnosis. Acta Chir Scand 1990 ; 156 : 127-30.
    • (1990) Acta Chir Scand , vol.156 , pp. 127-130
    • Torp, S.H.1    Skjorten, F.J.2
  • 9
    • 0028834880 scopus 로고
    • Accuracy of frozen section diagnosis of mammographically directed breast biopsies
    • Ferreiro JA. Accuracy of frozen section diagnosis of mammographically directed breast biopsies. Am J Surg Pathol 1995 ; 19 : 1267-71.
    • (1995) Am J Surg Pathol , vol.19 , pp. 1267-1271
    • Ferreiro, J.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.