메뉴 건너뛰기




Volumn 100, Issue 11, 2002, Pages 646-651

Foetal heart rate patterns in early labour in low and high risk pregnancies and its correlation with perinatal outcome

Author keywords

Electronic foetal monitoring; Foetal distress; Foetal heart rate pattern; Intrapartum foetal asphyxia

Indexed keywords

ADULT; APGAR SCORE; ARTICLE; CONTROLLED STUDY; FEMALE; FETAL HEART RATE PATTERN; FETUS ELECTROCARDIOGRAPHY; FETUS HEART RATE; HIGH RISK PREGNANCY; HUMAN; LABOR; MAJOR CLINICAL STUDY; OUTCOMES RESEARCH; PERINATAL MORBIDITY; PRENATAL PERIOD; PRIMIGRAVIDA; PROSPECTIVE STUDY; RISK FACTOR; UTERUS CONTRACTION; FETUS MONITORING; LABOR COMPLICATION; NEWBORN; PREDICTION AND FORECASTING; PREGNANCY; PREGNANCY OUTCOME;

EID: 0038578060     PISSN: 00195847     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (10)
  • 1
    • 0029049174 scopus 로고
    • Efficacy and safety of intrapartum electronic fetal monitoring: An update
    • Thacker SB, Stroup DF, Peterson HB - Efficacy and safety of intrapartum electronic fetal monitoring: an update. Obstet Gynecol 1995; 86: 613-20.
    • (1995) Obstet Gynecol , vol.86 , pp. 613-620
    • Thacker, S.B.1    Stroup, D.F.2    Peterson, H.B.3
  • 2
    • 0043144132 scopus 로고
    • Prenatal and intrapartum high risk screening. I:Predictors of the high risk neonate
    • Hobel CJ, Hyvarian MA, Okada DM - Prenatal and intrapartum high risk screening. I:Predictors of the high risk neonate. Am J Obstet Gynecol 1973; 116: 1171-3.
    • (1973) Am J Obstet Gynecol , vol.116 , pp. 1171-1173
    • Hobel, C.J.1    Hyvarian, M.A.2    Okada, D.M.3
  • 4
    • 0026580043 scopus 로고
    • The accuracy of auscultatory detection of fetal cardiac decelerations: A computer simulation
    • Schifrin BS, Amsel J, Burdorf G - The accuracy of auscultatory detection of fetal cardiac decelerations: a computer simulation. Am J Obstet Gynecol 1992; 166: 566-76.
    • (1992) Am J Obstet Gynecol , vol.166 , pp. 566-576
    • Schifrin, B.S.1    Amsel, J.2    Burdorf, G.3
  • 5
    • 0016772732 scopus 로고
    • Relationship between continuos foetal heart rate patterns and Apgar score in the newborn
    • Bisonette JM - Relationship between continuos foetal heart rate patterns and Apgar score in the newborn. Br J Obstet Gynaecol 1975; 82: 24-8.
    • (1975) Br J Obstet Gynaecol , vol.82 , pp. 24-28
    • Bisonette, J.M.1
  • 6
    • 0031719045 scopus 로고    scopus 로고
    • Admission test: A predictive test for foetal distress in high risk labour
    • Kulkarni A - Admission test: a predictive test for foetal distress in high risk labour. J Obstet Gynaecol Res 1998; 24: 255-9.
    • (1998) J Obstet Gynaecol Res , vol.24 , pp. 255-259
    • Kulkarni, A.1
  • 7
    • 0018957180 scopus 로고
    • A one-year study of routine fetal heart rate monitoring during the first stage of labor
    • Ingemarsson E, Ingemarsson I, Solum T, Westgren M - A one-year study of routine fetal heart rate monitoring during the first stage of labor. Acta Obstet Gynecol Scand 1980; 59: 297-300.
    • (1980) Acta Obstet Gynecol Scand , vol.59 , pp. 297-300
    • Ingemarsson, E.1    Ingemarsson, I.2    Solum, T.3    Westgren, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.