메뉴 건너뛰기




Volumn 20, Issue 5, 2003, Pages 411-422

A method of detecting and quantifying severity of myocardial perfusion defects with intravenous ultrasound contrast and breath holding during stress echocardiography

Author keywords

Microbubbles; Myocardial contrast; Pulmonary venous return; Respiration

Indexed keywords

DOBUTAMINE; ECHO CONTRAST MEDIUM;

EID: 0038575230     PISSN: 07422822     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1540-8175.2003.03078.x     Document Type: Article
Times cited : (2)

References (15)
  • 1
    • 0030889485 scopus 로고    scopus 로고
    • Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging
    • Porter TR, Li S, Kricsfeld D, et al. Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging. J Am Coll Cardiol 1997;29:791-799.
    • (1997) J Am Coll Cardiol , vol.29 , pp. 791-799
    • Porter, T.R.1    Li, S.2    Kricsfeld, D.3
  • 2
    • 0030792911 scopus 로고    scopus 로고
    • 99mTc-sestamibi single photon emission computed tomography
    • 99mTc-sestamibi single photon emission computed tomography. Circulation 1997;96:785-792.
    • (1997) Circulation , vol.96 , pp. 785-792
    • Kaul, S.1    Senior, R.2    Dittrich, H.3
  • 3
    • 0034604241 scopus 로고    scopus 로고
    • Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress
    • Heinle SK, Noblin J, Goree-Best P, et al. Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress. Circulation 2000;102:55-60.
    • (2000) Circulation , vol.102 , pp. 55-60
    • Heinle, S.K.1    Noblin, J.2    Goree-Best, P.3
  • 5
    • 0026948939 scopus 로고
    • Normal pulmonary venous flow characteristics as assessed by transesophageal pulsed Doppler echocardiography
    • Meijburg HWJ, Visser CA, Westerhof PW, et al. Normal pulmonary venous flow characteristics as assessed by transesophageal pulsed Doppler echocardiography. J Am Soc Echocardiogr 1992;5:588-597.
    • (1992) J Am Soc Echocardiogr , vol.5 , pp. 588-597
    • Meijburg, H.W.J.1    Visser, C.A.2    Westerhof, P.W.3
  • 6
    • 0021014782 scopus 로고
    • Radionuclide analysis of sequential changes in central circulatory volumes: Inspiration, expiration, and the Valsalva maneuver
    • Slutsky RA, Dittrich H, Peck WW. Radionuclide analysis of sequential changes in central circulatory volumes: Inspiration, expiration, and the Valsalva maneuver. Crit Care Med 1983;11:913-917.
    • (1983) Crit Care Med , vol.11 , pp. 913-917
    • Slutsky, R.A.1    Dittrich, H.2    Peck, W.W.3
  • 7
    • 0018750969 scopus 로고
    • Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease
    • Diamond CA, Forrester JS. Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease. New Engl J Med 1979;300:1350-1358.
    • (1979) New Engl J Med , vol.300 , pp. 1350-1358
    • Diamond, C.A.1    Forrester, J.S.2
  • 8
    • 0028129040 scopus 로고
    • Quantification of myocardial perfusion with myocardial contrast echocardiography during left atrial injection of contrast. Implication of venous injection
    • Skyba DM, Jayaweera AR, Goodman NC, et al. Quantification of myocardial perfusion with myocardial contrast echocardiography during left atrial injection of contrast. Implication of venous injection. Circulation 1994;90:1513-1521.
    • (1994) Circulation , vol.90 , pp. 1513-1521
    • Skyba, D.M.1    Jayaweera, A.R.2    Goodman, N.C.3
  • 9
    • 0026042931 scopus 로고
    • Quantitation of myocardial perfusion with contrast echocardiography
    • Kaul S. Quantitation of myocardial perfusion with contrast echocardiography. Am J Card Imaging 1991;5:200-206.
    • (1991) Am J Card Imaging , vol.5 , pp. 200-206
    • Kaul, S.1
  • 10
    • 0030730241 scopus 로고    scopus 로고
    • Myocardial contrast echocardiography
    • Kaul S. Myocardial contrast echocardiography. Circulation 1997;96:3745-3760.
    • (1997) Circulation , vol.96 , pp. 3745-3760
    • Kaul, S.1
  • 11
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
    • Wei K, Jayaweera AR, Firoozan S, et al. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 1998;97:473-483.
    • (1998) Circulation , vol.97 , pp. 473-483
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3
  • 12
    • 0023088701 scopus 로고
    • Immediate effect of expiratory loading on left ventricular stroke volume
    • Natarjan TK, Wise RA, Karam M, et al. Immediate effect of expiratory loading on left ventricular stroke volume. Circulation 1987;75:139-145.
    • (1987) Circulation , vol.75 , pp. 139-145
    • Natarjan, T.K.1    Wise, R.A.2    Karam, M.3
  • 13
    • 0037176971 scopus 로고    scopus 로고
    • Perfusion versus function: The ischemic cascade in demand ischemia: Implications of single-vessel versus multi-vessel stenosis
    • Leong-Poi H, Rim SJ, Le DE, et al. Perfusion versus function: The ischemic cascade in demand ischemia: implications of single-vessel versus multi-vessel stenosis. Circulation 2002;105:987-992.
    • (2002) Circulation , vol.105 , pp. 987-992
    • Leong-Poi, H.1    Rim, S.J.2    Le, D.E.3
  • 14
    • 0035282050 scopus 로고    scopus 로고
    • Real-time perfusion imaging with low mechanical index pulse inversion doppler imaging
    • Porter TR, Xie F, Silver M, et al. Real-time perfusion imaging with low mechanical index pulse inversion doppler imaging. J Am Coll Cardiol 2001;37:748-753.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 748-753
    • Porter, T.R.1    Xie, F.2    Silver, M.3
  • 15
    • 0035206573 scopus 로고    scopus 로고
    • Pharmacologic stress testing for coronary disease diagnosis: A meta-analysis
    • Kim C, Kwok YS, Heagerty P, et al. Pharmacologic stress testing for coronary disease diagnosis: a meta-analysis. Am Heart J 2001;142:934-944.
    • (2001) Am Heart J , vol.142 , pp. 934-944
    • Kim, C.1    Kwok, Y.S.2    Heagerty, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.