메뉴 건너뛰기




Volumn 3, Issue , 2000, Pages 1344-1349

An accurate fault location algorithm for double-circuit transmission systems

Author keywords

Current distribution factor; Double circuit transmission line; Fault location algorithm; Fault locator

Indexed keywords

CAPACITANCE; ELECTRIC CURRENT DISTRIBUTION; ELECTRIC FAULT LOCATION; ELECTRIC IMPEDANCE; ELECTRIC LINES; ELECTRIC POWER FACTOR; ELECTRIC POWER TRANSMISSION; ELECTRIC POWER TRANSMISSION NETWORKS;

EID: 0038492582     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (43)

References (6)
  • 1
    • 0025517399 scopus 로고
    • Accurate fault location technique for power transmission lines
    • November
    • A. T. Johns, S. Jamali, "Accurate Fault Location Technique for Power Transmission Lines," IEE Proceedings, Vol. 137, Pt. C, No. 6, November 1990, pp.395-402
    • (1990) IEE Proceedings , vol.137 , Issue.6 PART C , pp. 395-402
    • Johns, A.T.1    Jamali, S.2
  • 2
    • 0027635001 scopus 로고
    • A practical approach to accurate fault location on extra high voltage teed feeders
    • July
    • R. K. Aggarwal, D. V. Coury, A. T. Johns, A. Kalam, "A Practical Approach to Accurate Fault Location on Extra High Voltage Teed Feeders", IEEE Transactions on Power Delivery, Vol. 8, No. 3, July 1993, pp.874-883
    • (1993) IEEE Transactions on Power Delivery , vol.8 , Issue.3 , pp. 874-883
    • Aggarwal, R.K.1    Coury, D.V.2    Johns, A.T.3    Kalam, A.4
  • 3
    • 0032155849 scopus 로고    scopus 로고
    • Digital distance relaying algorithm for first-zone protection for parallel transmission lines
    • September
    • Y. Liao, S. Elangovan, "Digital Distance Relaying Algorithm for First-zone Protection for Parallel Transmission Lines", IEE Proceedings-Generation Transmission and Distribution, Vol. 145, No. 5, September 1998, pp.531-536
    • (1998) IEE Proceedings-Generation Transmission and Distribution , vol.145 , Issue.5 , pp. 531-536
    • Liao, Y.1    Elangovan, S.2
  • 4
    • 0032188351 scopus 로고    scopus 로고
    • Transmission line fault location for single-phase-to-earth fault on non-direct-ground neutral system
    • October
    • Zhang Qingchao, Zhang Yao, Song, Wennan, Fang Dazhong, "Transmission Line Fault Location for Single-phase-to-earth Fault on Non-direct-ground Neutral System", IEEE Transactions on Power Delivery, Vol. 13, No. 4, October 1998, pp.1086-1092
    • (1998) IEEE Transactions on Power Delivery , vol.13 , Issue.4 , pp. 1086-1092
    • Zhang, Q.1    Zhang, Q.Y.2    Song, Y.W.3    Fang, D.4
  • 5
    • 0032677143 scopus 로고    scopus 로고
    • Fault location of two-parallel transmission line for non-earth fault using one-terminal data
    • July
    • Zhang Qingchao , Zhang Yao, Song Wennan, Yu Yixin, Wang Zhigang, "Fault Location of Two-parallel Transmission Line for Non-earth Fault Using One-terminal Data", IEEE Transactions on Power Delivery, Vol. 14, No. 3, July 1999, pp.863-867
    • (1999) IEEE Transactions on Power Delivery , vol.14 , Issue.3 , pp. 863-867
    • Zhang, Q.1    Zhang, Y.2    Song, W.3    Yu, Y.4    Wang, Z.5
  • 6
    • 0032187490 scopus 로고    scopus 로고
    • Distance protection and fault location utilizing only phase current phasors
    • October
    • M. B. Djuric, Z. M. Radojevic, V. V. Terzija, "Distance Protection and Fault Location Utilizing Only Phase Current Phasors", IEEE Transactions on Power Delivery, Vol. 13, No. 4, October 1998, pp.1020-1026
    • (1998) IEEE Transactions on Power Delivery , vol.13 , Issue.4 , pp. 1020-1026
    • Djuric, M.B.1    Radojevic, Z.M.2    Terzija, V.V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.