메뉴 건너뛰기




Volumn 3, Issue , 2000, Pages 1350-1354

A new fault location algorithm for series compensated lines using synchronized phasor measurements

Author keywords

FACTS; Series compensation; Synchronized phasor measurement units

Indexed keywords

CAPACITANCE; ELECTRIC FAULT LOCATION; ELECTRIC LINES; ELECTRIC POWER FACTOR CORRECTION; ELECTRIC POWER SYSTEM PROTECTION; ELECTRIC RESISTANCE; ELECTRIC VARIABLES MEASUREMENT; ERROR COMPENSATION;

EID: 0038492573     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (14)

References (14)
  • 1
    • 0023670142 scopus 로고
    • A linearized model for MOV-protected series capacitors
    • November
    • Goldswortyh D.L., "A linearized model for MOV-protected series capacitors", IEEE Transactions on Power Systems, Vol. 2, No. 4, November 1987, pp.953-958.
    • (1987) IEEE Transactions on Power Systems , vol.2 , Issue.4 , pp. 953-958
    • Goldswortyh, D.L.1
  • 3
    • 0027629309 scopus 로고
    • Thyristor controlled series compensation prototype installation at the slatt 500KV substation
    • July
    • Urbanek J., Piwko R.J., Damsky B.L., Furumasu B.C. and Mittlestadt W., "Thyristor controlled series compensation prototype installation at the slatt 500KV substation", IEEE Transactions on Power Delivery, Vol.8, No.3, July 1993, pp.1460-1469.
    • (1993) IEEE Transactions on Power Delivery , vol.8 , Issue.3 , pp. 1460-1469
    • Urbanek, J.1    Piwko, R.J.2    Damsky, B.L.3    Furumasu, B.C.4    Mittlestadt, W.5
  • 4
    • 0032627589 scopus 로고    scopus 로고
    • Using a miniature model and EMTP simulations to evaluate new methods to control and protect a thyristor-controlled series compensator
    • Tanaka Y., Taniguchi H., Egawa M., Fujita H., Watanabe M. and Konishi H., "Using a miniature model and EMTP simulations to evaluate new methods to control and protect a thyristor-controlled series compensator", IEEE Winter Meeting 1999.
    • IEEE Winter Meeting 1999
    • Tanaka, Y.1    Taniguchi, H.2    Egawa, M.3    Fujita, H.4    Watanabe, M.5    Konishi, H.6
  • 5
    • 0030260934 scopus 로고    scopus 로고
    • Algorithm for location faults on series compensated lines using neural network and deterministic methods
    • October
    • Novosel D., Bachmann B., Hu Y. and Saha, M.M., "Algorithm for location faults on series compensated lines using neural network and deterministic methods", IEEE Transactions on Power Delivery, Vol.11, No.4, October 1996, pp. 1728-1736.
    • (1996) IEEE Transactions on Power Delivery , vol.11 , Issue.4 , pp. 1728-1736
    • Novosel, D.1    Bachmann, B.2    Hu, Y.3    Saha, M.M.4
  • 7
    • 0037567275 scopus 로고    scopus 로고
    • An adaptive protection scheme for advanced series compensated (ASC) transmission lines
    • April
    • Girgis A.A., Sallam A.A. and El-Din A. Karim, "An adaptive protection scheme for advanced series compensated (ASC) transmission lines", IEEE Transactions on Power Delivery, Vol. 13, No. 2, April 1998, pp.414-420.
    • (1998) IEEE Transactions on Power Delivery , vol.13 , Issue.2 , pp. 414-420
    • Girgis, A.A.1    Sallam, A.A.2    Karim, E.A.3
  • 8
    • 0028426833 scopus 로고
    • An accurate fault location algorithm using synchronized sampling
    • Kezunovic M., Mrlic J. and Perunicic B., "An accurate fault location algorithm using synchronized sampling", Electric Power Systems Research, Vol.2, 1994 pp.161-169.
    • (1994) Electric Power Systems Research , vol.2 , pp. 161-169
    • Kezunovic, M.1    Mrlic, J.2    Perunicic, B.3
  • 9
    • 0034171499 scopus 로고    scopus 로고
    • An adaptive PMU based fault detection/location technique for transmission lines, Part I: Theory and algorithms
    • Jiang J.A., Yang J.Z., Lin Y.H., Liu C.W. and Ma J.C., "An adaptive PMU based fault detection/location technique for transmission lines, Part I: Theory and algorithms", accepted by IEEE Transactions on Power Delivery.
    • IEEE Transactions on Power Delivery
    • Jiang, J.A.1    Yang, J.Z.2    Lin, Y.H.3    Liu, C.W.4    Ma, J.C.5
  • 10
    • 0034289942 scopus 로고    scopus 로고
    • An adaptive PMU based fault detection/location technique for transmission lines, Part II: PMU implementation and performance evaluation
    • Jiang J.A., Lin Y.H., Yang J.Z., Too T.M. and Liu C.W., "An adaptive PMU based fault detection/location technique for transmission lines, Part II: PMU implementation and performance evaluation", accepted by IEEE Transactions on Power Delivery.
    • IEEE Transactions on Power Delivery
    • Jiang, J.A.1    Lin, Y.H.2    Yang, J.Z.3    Too, T.M.4    Liu, C.W.5
  • 12
    • 84954443034 scopus 로고    scopus 로고
    • Complete elimination of DC offset in current signals for relaying applications
    • Yang J.Z., Liu C.W., "Complete Elimination of DC offset in current signals for relaying applications", accepted by IEEE Winter Meeting, 2000.
    • IEEE Winter Meeting, 2000
    • Yang, J.Z.1    Liu, C.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.