The need for phase-encoding flow compensation in high-resolution intracranial magnetic resonance angiography

Author keywords

Intracranial MRA; MRA; Phase encoding; Phase frequency artifact; Vascular image quality

Indexed keywords

ARTICLE; ARTIFACT REDUCTION; BLOOD FLOW; BRAIN ARTERY; HUMAN; IMAGE ENHANCEMENT; MAGNETIC RESONANCE ANGIOGRAPHY; PRIORITY JOURNAL;

EID: 0038449820     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.10322     Document Type: Article
Times cited : (22)

References (20)
  • 1
    • 0038326015 scopus 로고
    • Oblique vascular displacement flow artifacts in conventional MRI sequences
    • Moran PR, Nalcioglu O, Juh SC. Oblique vascular displacement flow artifacts in conventional MRI sequences. Magn Reson Imaging 1987;5(Suppl 1):34-35.
    • (1987) Magn Reson Imaging , vol.5 , Issue.SUPPL. 1 , pp. 34-35
    • Moran, P.R.1    Nalcioglu, O.2    Juh, S.C.3
  • 2
    • 0024999782 scopus 로고
    • Spatial misregistration of vascular flow during MR imaging of the CNS: Cause and clinical significance
    • Larson TC, Kelly WM, Ehman RL, Wehrli FW. Spatial misregistration of vascular flow during MR imaging of the CNS: cause and clinical significance. AJR Am J Roentgenol 1990;155:1117-1124.
    • (1990) AJR Am J Roentgenol , vol.155 , pp. 1117-1124
    • Larson, T.C.1    Kelly, W.M.2    Ehman, R.L.3    Wehrli, F.W.4
  • 3
    • 0026876194 scopus 로고
    • Elimination of oblique flow artifacts in magnetic resonance imaging
    • Frank LR, Crawley AC, Buxton RB. Elimination of oblique flow artifacts in magnetic resonance imaging. Magn Reson Med 1992;25:299-307.
    • (1992) Magn Reson Med , vol.25 , pp. 299-307
    • Frank, L.R.1    Crawley, A.C.2    Buxton, R.B.3
  • 5
    • 0027093023 scopus 로고
    • Projection reconstruction techniques for reduction of motion effects in MRI
    • Glover G, Pauly J. Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson Med 1992;28:275-289.
    • (1992) Magn Reson Med , vol.28 , pp. 275-289
    • Glover, G.1    Pauly, J.2
  • 6
    • 0026344889 scopus 로고
    • On the nature and reduction of the displacement artifact in flow images
    • Nishimura DG, Jackson JI, Pauly JM. On the nature and reduction of the displacement artifact in flow images. Magn Reson Med 1991;22:481-492.
    • (1991) Magn Reson Med , vol.22 , pp. 481-492
    • Nishimura, D.G.1    Jackson, J.I.2    Pauly, J.M.3
  • 7
    • 0025797766 scopus 로고
    • Experiments for two MR imaging theories of motion phase sensitivity
    • Moran PR. Experiments for two MR imaging theories of motion phase sensitivity. Radiology 1991;180:115-119.
    • (1991) Radiology , vol.180 , pp. 115-119
    • Moran, P.R.1
  • 8
    • 0027414814 scopus 로고
    • Distortions from curved flow in magnetic resonance imaging
    • Frank LR, Buxton RB. Distortions from curved flow in magnetic resonance imaging. Magn Reson Med 1993;29:84-93.
    • (1993) Magn Reson Med , vol.29 , pp. 84-93
    • Frank, L.R.1    Buxton, R.B.2
  • 12
    • 0023013859 scopus 로고
    • Reducing motion artifacts in two-dimensional Fourier transform imaging
    • Haacke EM, Patric JL. Reducing motion artifacts in two-dimensional Fourier transform imaging. Magn Reson Imag 1986;4:962-963.
    • (1986) Magn Reson Imag , vol.4 , pp. 962-963
    • Haacke, E.M.1    Patric, J.L.2
  • 13
    • 0026953545 scopus 로고
    • Altered phase-encoding order for reduced sensitivity to motion corruption in 3DFT MR imaging
    • Korin HW, Riederer SJ, Bampton AEH, Ehman RL. Altered phase-encoding order for reduced sensitivity to motion corruption in 3DFT MR imaging. J Magn Reson Imag 1992;2:687-693.
    • (1992) J Magn Reson Imag , vol.2 , pp. 687-693
    • Korin, H.W.1    Riederer, S.J.2    Bampton, A.E.H.3    Ehman, R.L.4
  • 14
    • 0030705199 scopus 로고    scopus 로고
    • Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging
    • Wilman AH, Riederer SJ. Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging. Magn Reson Med 1997;38:793-802.
    • (1997) Magn Reson Med , vol.38 , pp. 793-802
    • Wilman, A.H.1    Riederer, S.J.2
  • 18
    • 0028830695 scopus 로고
    • The voxel sensitivity function in Fourier transform magnetic resonance imaging: Applications to magnetic resonance angiography
    • Parker DL, Du Y, Davis WL. The voxel sensitivity function in Fourier transform magnetic resonance imaging: applications to magnetic resonance angiography. Magn Reson Med 1995;33:156-162.
    • (1995) Magn Reson Med , vol.33 , pp. 156-162
    • Parker, D.L.1    Du, Y.2    Davis, W.L.3
  • 19
    • 0038664633 scopus 로고
    • Motion artifacts and motion compensation
    • Potchen EJ, Haacke EM, Siebert JE, Gottschalk A, editors. St. Louis: Mosby-Year Book
    • Duerk JL, Wendt III RE. Motion artifacts and motion compensation. In: Potchen EJ, Haacke EM, Siebert JE, Gottschalk A, editors. Magnetic resonance angiography. St. Louis: Mosby-Year Book; 1993. p 80-133.
    • (1993) Magnetic Resonance Angiography , pp. 80-133
    • Duerk, J.L.1    Wendt R.E. III2
  • 20
    • 0036788332 scopus 로고    scopus 로고
    • Reduction of flow-related signal loss in flow-compensated 3D TOF, using variable echo time (3D TOF-VTE)
    • Jeong EK, Parker DL. Reduction of flow-related signal loss in flow-compensated 3D TOF, using variable echo time (3D TOF-VTE). Magn Reson Med 2002;48:667-676.
    • (2002) Magn Reson Med , vol.48 , pp. 667-676
    • Jeong, E.K.1    Parker, D.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.