메뉴 건너뛰기




Volumn 13, Issue 4, 2003, Pages 734-739

PET/CT of the abdomen: Optimizing the patient breathing pattern

Author keywords

Co registration; Image; Movement artifact; PET CT; Respiration

Indexed keywords

ABDOMINAL SCINTISCANNING; ADULT; AGED; ANALYSIS OF VARIANCE; ARTICLE; BLADDER; BREATH HOLDING; BREATHING PATTERN; CANCER STAGING; CLINICAL ARTICLE; CLINICAL PROTOCOL; CONTROLLED STUDY; DEVICE; DIAGNOSTIC IMAGING; DIAGNOSTIC PROCEDURE; EXHALATION; FEMALE; FORCED EXPIRATION; HUMAN; INHALATION; KIDNEY; LIVER; MALE; MEASUREMENT; OBSERVER VARIATION; POSITRON EMISSION TOMOGRAPHY; PRIORITY JOURNAL; SACRUM; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; SPLEEN; WILCOXON SIGNED RANKS TEST;

EID: 0038419568     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-002-1548-2     Document Type: Article
Times cited : (110)

References (10)
  • 2
    • 77049180654 scopus 로고
    • Movements of the thoracic cage and diaphragm in respiration
    • Wade OL (1954) Movements of the thoracic cage and diaphragm in respiration. J Physiol 124:193-212
    • (1954) J. Physiol. , vol.124 , pp. 193-212
    • Wade, O.L.1
  • 4
    • 0033623638 scopus 로고    scopus 로고
    • Radiation exposure to patients caused by single-photon transmission measurement in PET
    • Schaefer A, Seifert H, Donsch P, Kirsch CM (2000) Radiation exposure to patients caused by single-photon transmission measurement in PET. Nuklearmedizin 39:204-208
    • (2000) Nuklearmedizin , vol.39 , pp. 204-208
    • Schaefer, A.1    Seifert, H.2    Donsch, P.3    Kirsch, C.M.4
  • 5
    • 0031791001 scopus 로고    scopus 로고
    • Attenuation correction for a combined 3D PET/CT scanner
    • Kinahan PE, Townsend DW, Beyer T, Sashin D (1998) Attenuation correction for a combined 3D PET/CT scanner. Med Phys 25:2046-2053
    • (1998) Med. Phys. , vol.25 , pp. 2046-2053
    • Kinahan, P.E.1    Townsend, D.W.2    Beyer, T.3    Sashin, D.4
  • 7
    • 80051735095 scopus 로고    scopus 로고
    • A JAVA environment for medical image data analysis: Initial application for brain PET quantitation
    • Mikolajczyk K, Szabatin M, Rudnicki P, Grodzki M, Burger C (1998) A JAVA environment for medical image data analysis: initial application for brain PET quantitation. Med Inform (Lond) 23:207-214
    • (1998) Med. Inform. (Lond) , vol.23 , pp. 207-214
    • Mikolajczyk, K.1    Szabatin, M.2    Rudnicki, P.3    Grodzki, M.4    Burger, C.5
  • 10
    • 0028289096 scopus 로고
    • Predictive respiratory gating: A new method to reduce motion artifacts on CT scan
    • Ritchie CJ, Hsieh J, Gard MF, Godwin JD (1994) Predictive respiratory gating: a new method to reduce motion artifacts on CT scan. Radiology 190:847-852
    • (1994) Radiology , vol.190 , pp. 847-852
    • Ritchie, C.J.1    Hsieh, J.2    Gard, M.F.3    Godwin, J.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.