Volumn 14, Issue 6, 2003, Pages 862-867

A hand-held optical sensor for dissolved oxygen measurement

Author keywords

All solid state device; Dissolved oxygen sensor

Indexed keywords

DYES; LIGHT EMITTING DIODES; LUMINESCENCE; OXYGEN; RUBBER FILMS; SILICA GEL;

EID: 0038417183     PISSN: 09570233     EISSN: None     Source Type: Journal    
DOI: 10.1088/0957-0233/14/6/323     Document Type: Article
Times cited : (25)

References (18)
  • 2
    • 0029348430 scopus 로고
    • Development of a submicrometer optical fiber oxygen sensor
    • Rosenzweig Z and Kopelman R 1995 Development of a submicrometer optical fiber oxygen sensor Anal. Chem. 67 2650
    • (1995) Anal. Chem. , vol.67 , pp. 2650
    • Rosenzweig, Z.1    Kopelman, R.2
  • 3
    • 0031042387 scopus 로고    scopus 로고
    • Fluorescence-based thin plastic film ion-pair sensors for oxygen
    • Mills A and Thomas M 1997 Fluorescence-based thin plastic film ion-pair sensors for oxygen Analyst 122 63
    • (1997) Analyst , vol.122 , pp. 63
    • Mills, A.1    Thomas, M.2
  • 4
    • 0032584302 scopus 로고    scopus 로고
    • Fiber-optic oxygen sensor based on the fluorescence quenching of tris(5-acrylamido. 1, 10 phenanthroline) ruthenium chloride
    • McNamara K P, Li X, Stull A D and Rosenzweig Z 1998 Fiber-optic oxygen sensor based on the fluorescence quenching of tris(5-acrylamido. 1, 10 phenanthroline) ruthenium chloride Anal. Chim. Acta 361 73
    • (1998) Anal. Chim. Acta , vol.361 , pp. 73
    • McNamara, K.P.1    Li, X.2    Stull, A.D.3    Rosenzweig, Z.4
  • 5
    • 0032988939 scopus 로고    scopus 로고
    • Linear calibration function of luminescence quenching-based optical sensor for trace oxygen analysis
    • Choi M M F and Xiao D 1999 Linear calibration function of luminescence quenching-based optical sensor for trace oxygen analysis Analyst 124 695
    • (1999) Analyst , vol.124 , pp. 695
    • Choi, M.M.F.1    Xiao, D.2
  • 6
    • 0033200214 scopus 로고    scopus 로고
    • In situ fiber-optic oxygen consumption measurements from a working mouse heart
    • Zhao Y, Richman A, Storey C, Radford N B and Pantano P 1999 In situ fiber-optic oxygen consumption measurements from a working mouse heart Anal. Chem. 71 3887
    • (1999) Anal. Chem. , vol.71 , pp. 3887
    • Zhao, Y.1    Richman, A.2    Storey, C.3    Radford, N.B.4    Pantano, P.5
  • 7
    • 0033990915 scopus 로고    scopus 로고
    • Single standard calibration for an optical oxygen sensor based on luminescence quenching of a ruthenium complex
    • Choi M M F and Xiao D 2000 Single standard calibration for an optical oxygen sensor based on luminescence quenching of a ruthenium complex Anal. Chim. Acta 403 57
    • (2000) Anal. Chim. Acta , vol.403 , pp. 57
    • Choi, M.M.F.1    Xiao, D.2
  • 10
    • 0001152679 scopus 로고
    • Photoluminescence of pyrenebutyric acid incorporated into silicone film as a technique in luminescence oxygen sensing
    • Ishiji T and Kaneko M 1995 Photoluminescence of pyrenebutyric acid incorporated into silicone film as a technique in luminescence oxygen sensing Analyst 120 1633
    • (1995) Analyst , vol.120 , pp. 1633
    • Ishiji, T.1    Kaneko, M.2
  • 11
    • 0031806887 scopus 로고    scopus 로고
    • Oxygen detection by fluorescence quenching of tetraphenylporphyrin immobilized in the original cladding of an optical fiber
    • Potyrailo R A and Hieftje G M 1998 Oxygen detection by fluorescence quenching of tetraphenylporphyrin immobilized in the original cladding of an optical fiber Anal. Chim. Acta 370 1
    • (1998) Anal. Chim. Acta , vol.370 , pp. 1
    • Potyrailo, R.A.1    Hieftje, G.M.2
  • 12
    • 0031042977 scopus 로고    scopus 로고
    • Optical sensor for oxygen using a porphyrin-doped sol-gel glass
    • Lee S K and Okura I 1997 Optical sensor for oxygen using a porphyrin-doped sol-gel glass Analyst 122 81
    • (1997) Analyst , vol.122 , pp. 81
    • Lee, S.K.1    Okura, I.2
  • 13
    • 0032954989 scopus 로고    scopus 로고
    • Oxygen-sensitive reverse-phase optode membrane using silica gel-adsorbed ruthenium(II) complex embedded in gelatin film
    • Choi M M F and Xio D 1999 Oxygen-sensitive reverse-phase optode membrane using silica gel-adsorbed ruthenium(II) complex embedded in gelatin film Anal. Chim. Acta 387 197
    • (1999) Anal. Chim. Acta , vol.387 , pp. 197
    • Choi, M.M.F.1    Xiao, D.2
  • 14
    • 0034833374 scopus 로고    scopus 로고
    • An optical glucose biosensor with eggshell membrane as an enzyme immobilisation platform
    • Choi M M F, Pang W S H, Xiao D and Wu X 2001 An optical glucose biosensor with eggshell membrane as an enzyme immobilisation platform Analyst 126 1558
    • (2001) Analyst , vol.126 , pp. 1558
    • Choi, M.M.F.1    Pang, W.S.H.2    Xiao, D.3    Wu, X.4
  • 15
    • 0037083856 scopus 로고    scopus 로고
    • Aspartame optical biosensor with bienzyme-immobilized eggshell membrane and oxygen-sensitive optode membrane
    • Xiao D and Choi M M F 2002 Aspartame optical biosensor with bienzyme-immobilized eggshell membrane and oxygen-sensitive optode membrane Anal. Chem. 74 863
    • (2002) Anal. Chem. , vol.74 , pp. 863
    • Xiao, D.1    Choi, M.M.F.2
  • 17
    • 11944265432 scopus 로고
    • Oxygen-sensitive luminescent materials based on silicone-soluble ruthenium diimine complexes
    • Kilmant I and Wolfbeis O S 1995 Oxygen-sensitive luminescent materials based on silicone-soluble ruthenium diimine complexes Anal. Chem. 67 3160
    • (1995) Anal. Chem. , vol.67 , pp. 3160
    • Kilmant, I.1    Wolfbeis, O.S.2
  • 18
    • 0002388667 scopus 로고
    • Über die Abklingungszeit der Fluoreszenz
    • Stern V O and Volmer M 1919 Ũber die Abklingungszeit der Fluoreszenz Phys. Z. 20 183
    • (1919) Phys. Z. , vol.20 , pp. 183
    • Stern, V.O.1    Volmer, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.