메뉴 건너뛰기




Volumn 36, Issue 8, 2003, Pages 1219-1223

Quantifying translations in the radiohumeral joint: Application of a floating axis analysis

Author keywords

Electromagnetic tracking device; Joint coordinate system; Posterolateral rotatory instability; Radiohumeral translation

Indexed keywords

ALGORITHMS; ELECTROMAGNETISM; JOINTS (ANATOMY);

EID: 0038385524     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0021-9290(03)00103-9     Document Type: Article
Times cited : (8)

References (16)
  • 1
    • 0001768961 scopus 로고    scopus 로고
    • Biomechanics of the elbow
    • B.F. Morrey. Philadelphia: WB Saunders Company
    • An K.N., Morrey B.F. Biomechanics of the elbow. Morrey B.F. The Elbow and its Disorders. 3rd Edition:2000;43-60 WB Saunders Company, Philadelphia.
    • (2000) The Elbow and its Disorders 3rd Edition , pp. 43-60
    • An, K.N.1    Morrey, B.F.2
  • 3
  • 4
    • 0031018823 scopus 로고    scopus 로고
    • Rotatory instability of the elbow: The anatomy and role of the lateral stabilizers
    • Cohen M.S., Hastings H. Rotatory instability of the elbow. the anatomy and role of the lateral stabilizers Journal of Bone and Joint Surgery. 79A:1997;225-233.
    • (1997) Journal of Bone and Joint Surgery , vol.79 A , pp. 225-233
    • Cohen, M.S.1    Hastings, H.2
  • 6
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee
    • Grood E.S., Suntay W.J. A joint coordinate system for the clinical description of three-dimensional motions. application to the knee Journal of Biomechanical Engineering. 105:1983;136-144.
    • (1983) Journal of Biomechanical Engineering , vol.105 , pp. 136-144
    • Grood, E.S.1    Suntay, W.J.2
  • 9
    • 0030175849 scopus 로고    scopus 로고
    • Accuracy of an electromagnetic tracking device: A study of the optimal operating range and metal interference
    • Milne A.D., Chess D.G., Johnson J.A., King G.J.W. Accuracy of an electromagnetic tracking device. a study of the optimal operating range and metal interference Journal of Biomechanics. 29:1996;791-793.
    • (1996) Journal of Biomechanics , vol.29 , pp. 791-793
    • Milne, A.D.1    Chess, D.G.2    Johnson, J.A.3    King, G.J.W.4
  • 10
    • 0006907235 scopus 로고
    • The pathoanatomy and kinematics of posterolateral rotatory instability (pivot-shift) of the elbow
    • O'Driscoll S.W., Morrey B.F., Korinek S.L., An K.N. The pathoanatomy and kinematics of posterolateral rotatory instability (pivot-shift) of the elbow. Transactions of the ORS. 15(1):1990;6.
    • (1990) Transactions of the ORS , vol.15 , Issue.1 , pp. 6
    • O'Driscoll, S.W.1    Morrey, B.F.2    Korinek, S.L.3    An, K.N.4
  • 16
    • 0026552157 scopus 로고
    • Rationalization of kinematic descriptors for three-dimensional hand and finger motion
    • Small C.F., Bryant J.T., Pichora D.R. Rationalization of kinematic descriptors for three-dimensional hand and finger motion. Journal of Biomedical Engineering. 14:1992;133-141.
    • (1992) Journal of Biomedical Engineering , vol.14 , pp. 133-141
    • Small, C.F.1    Bryant, J.T.2    Pichora, D.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.