-
1
-
-
0024569815
-
Compensation of spatial system response in SPECT with conjugate gradient reconstruction technique
-
A. R. Formiconi, A. Pupi, and A. Passeri, “Compensation of spatial system response in SPECT with conjugate gradient reconstruction technique,” Phys. Med. Biol., vol. 34, pp. 69-84, 1990.
-
(1990)
Phys. Med. Biol.
, vol.34
, pp. 69-84
-
-
Formiconi, A.R.1
Pupi, A.2
Passeri, A.3
-
2
-
-
0001579739
-
Implementation of simultaneous attenuation and detector response correction in SPECT
-
B. M. W. Tsui, H. B. Hu, D. R. Gilland, and G. T. Gullberg, “Implementation of simultaneous attenuation and detector response correction in SPECT,” IEEE Trans. Nucl. Sci., vol. 35, pp. 778-783, 1988.
-
(1988)
IEEE Trans. Nucl. Sci.
, vol.35
, pp. 778-783
-
-
Tsui, B.M.W.1
Hu, H.B.2
Gilland, D.R.3
Gullberg, G.T.4
-
3
-
-
0026139673
-
Three-dimensional iterative reconstruction algorithm with attenuation and geometric point response correction
-
G. L. Zeng, G. T. Gullberg, B. M. W. Tsui, and J. A. Terry, “Three-dimensional iterative reconstruction algorithm with attenuation and geometric point response correction,” IEEE Trans. Nucl. Sci., vol. 38, pp. 693-702, 1991.
-
(1991)
IEEE Trans. Nucl. Sci.
, vol.38
, pp. 693-702
-
-
Zeng, G.L.1
Gullberg, G.T.2
Tsui, B.M.W.3
Terry, J.A.4
-
4
-
-
0026532033
-
Simultaneous compensation for attenuation, scatter, and detector response of SPECT reconstruction in three dimensions
-
Z. Liang, T. G. Turkington, D. R. Gilland, R. J. Jaszczak, and R. E. Coleman, “Simultaneous compensation for attenuation, scatter, and detector response of SPECT reconstruction in three dimensions,” Phys. Med. Biol., vol. 37, pp. 587-603, 1992.
-
(1992)
Phys. Med. Biol.
, vol.37
, pp. 587-603
-
-
Liang, Z.1
Turkington, T.G.2
Gilland, D.R.3
Jaszczak, R.J.4
Coleman, R.E.5
-
5
-
-
0037700094
-
Image reconstruction in quantitative cardiac SPECT with varying focal-length fan-beam collimators
-
Ph.D. dissertation, State Univ. New York, Stony Brook, NY, 404 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, JUNE 2003
-
G. Han, “Image reconstruction in quantitative cardiac SPECT with varying focal-length fan-beam collimators,” Ph.D. dissertation, State Univ. New York, Stony Brook, NY, 2000. 404 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 50, NO. 3, JUNE 2003
-
(2000)
, vol.50
, Issue.3
-
-
Han, G.1
-
6
-
-
0022961619
-
Novel properties of the fourier decomposition of the sinogram
-
P. R. Edholm, R. M. Lewitt, and B. Lindholm, “Novel properties of the fourier decomposition of the sinogram,” in Proc. SPIE Int. Workshop Physics Eng. Computerized Multidimensional Image Processing, 1986, pp. 169-173.
-
(1986)
in Proc. SPIE Int. Workshop Physics Eng. Computerized Multidimensional Image Processing
, pp. 169-173
-
-
Edholm, P.R.1
Lewitt, R.M.2
Lindholm, B.3
-
7
-
-
0001061520
-
Fourier method for correction of depth-dependent blurring
-
R. M. Lewitt, P. R. Edholm, andW. Xia, “Fourier method for correction of depth-dependent blurring,” SPIE Med. Imaging III, vol. 1092, pp. 232-239, 1989.
-
(1989)
SPIE Med. Imaging III
, vol.1092
, pp. 232-239
-
-
Lewitt, R.M.1
Edholm, P.R.2
Xia, W.3
-
8
-
-
0028449684
-
Noniterative compensation for the distance-dependent detector response and photon attenuation in SPECT imaging
-
S. J. Glick, B. C. Penney, M. A. King, and C. L. Byrne, “Noniterative compensation for the distance-dependent detector response and photon attenuation in SPECT imaging,” IEEE Trans. Med. Imaging, vol. 13, pp. 363-374, 1994.
-
(1994)
IEEE Trans. Med. Imaging
, vol.13
, pp. 363-374
-
-
Glick, S.J.1
Penney, B.C.2
King, M.A.3
Byrne, C.L.4
-
9
-
-
0024032820
-
The circular harmonic transform for SPECT reconstruction and boundary conditions on the fourier transform of the sinogram
-
W. G. Hawkins, P. K. Leichner, and N. Yang, “The circular harmonic transform for SPECT reconstruction and boundary conditions on the fourier transform of the sinogram,” IEEE Trans. Med.Imaging, vol. 7, pp. 135-148, 1988.
-
(1988)
IEEE Trans. Med.Imaging
, vol.7
, pp. 135-148
-
-
Hawkins, W.G.1
Leichner, P.K.2
Yang, N.3
-
10
-
-
0029263827
-
Fourier correction for spatially variant collimator blurring in SPECT
-
W. Xia, R. M. Lewitt, and P. R. Edholm, “Fourier correction for spatially variant collimator blurring in SPECT,” IEEE Trans. Med. Imaging, vol. 14, pp. 100-115, 1995.
-
(1995)
IEEE Trans. Med. Imaging
, vol.14
, pp. 100-115
-
-
Xia, W.1
Lewitt, R.M.2
Edholm, P.R.3
-
11
-
-
0037700093
-
Depth-dependent resolution deconvolution for myocardial perfusion SPECT with noncircular scan orbit
-
J. Ye and Z. Liang, “Depth-dependent resolution deconvolution for myocardial perfusion SPECT with noncircular scan orbit,” J. Nucl. Medicine, vol. 35, p. 190, 1994.
-
(1994)
J. Nucl. Medicine
, vol.35
, pp. 190
-
-
Ye, J.1
Liang, Z.2
-
12
-
-
0028025162
-
A filtering technique to compensate for detector response in converging-beam SPECT reconstruction
-
Z. Cao and B. M. W. Tsui, “A filtering technique to compensate for detector response in converging-beam SPECT reconstruction,” Phys. Med. Biol., vol. 39, pp. 1281-1293, 1994.
-
(1994)
Phys. Med. Biol.
, vol.39
, pp. 1281-1293
-
-
Cao, Z.1
Tsui, B.M.W.2
-
13
-
-
0003806997
-
An inversion formula for the attenuated X-ray transformation
-
preprint, May
-
R. Novikov, “An inversion formula for the attenuated X-ray transformation,” preprint, May 2000.
-
(2000)
-
-
Novikov, R.1
-
14
-
-
0035305957
-
A new SPECT reconstruction algorithm based on the Novikov's explicit inversion formula
-
L. Kunyansky, “A new SPECT reconstruction algorithm based on the Novikov's explicit inversion formula,” Inverse Problems, vol. 17, pp. 293-306, 2001.
-
(2001)
Inverse Problems
, vol.17
, pp. 293-306
-
-
Kunyansky, L.1
-
15
-
-
0036032119
-
Toward an analytical solution for 3D SPECT reconstruction with nonuniform attenuation and distance-dependent resolution variation: A Monte Carlo simulation study
-
H. Lu, J. Wen, X. Li, T. Li, G. Han, and Z. Liang, “Toward an analytical solution for 3D SPECT reconstruction with nonuniform attenuation and distance-dependent resolution variation: A Monte Carlo simulation study,” SPIE Med. Imaging, vol. 4684, pp. 20-28, 2002.
-
(2002)
SPIE Med. Imaging
, vol.4684
, pp. 20-28
-
-
Lu, H.1
Wen, J.2
Li, X.3
Li, T.4
Han, G.5
Liang, Z.6
-
16
-
-
0038376157
-
Fan-beam and variable focal-length fan-beam SPECT reconstruction with nonuniform attenuation
-
J. Wen, T. Li, X. Li, and Z. Liang, “Fan-beam and variable focal-length fan-beam SPECT reconstruction with nonuniform attenuation,” J. Nucl. Medicine Technol., vol. 30, p. 97, 2002.
-
(2002)
J. Nucl. Medicine Technol.
, vol.30
, pp. 97
-
-
Wen, J.1
Li, T.2
Li, X.3
Liang, Z.4
-
17
-
-
0038037871
-
Ray-driven analytical fan-beam SPECT reconstruction with nonuniform attenuation
-
J. Wen, T. Li, and Z. Liang, “Ray-driven analytical fan-beam SPECT reconstruction with nonuniform attenuation,” Proc. IEEE Int. Symp. Biomedical Imaging, pp. 629-632, 2002.
-
(2002)
Proc. IEEE Int. Symp. Biomedical Imaging
, pp. 629-632
-
-
Wen, J.1
Li, T.2
Liang, Z.3
-
18
-
-
0026928798
-
Frequency domain implementation of the three-dimensional geometric point response correction in SPECT imaging
-
G. L. Zeng and G. T. Gullberg, “Frequency domain implementation of the three-dimensional geometric point response correction in SPECT imaging,” IEEE Trans. Nucl. Sci., vol. 39, pp. 1444-1453, 1992.
-
(1992)
IEEE Trans. Nucl. Sci.
, vol.39
, pp. 1444-1453
-
-
Zeng, G.L.1
Gullberg, G.T.2
-
19
-
-
0019136137
-
The geometric transfer function component for scintillation camera collimators with straight parallel holes
-
C. E. Metz, F. B. Atkins, and B. N. Beck, “The geometric transfer function component for scintillation camera collimators with straight parallel holes,” Phys. Med. Biol., vol. 25, pp. 1059-1070, 1980.
-
(1980)
Phys. Med. Biol.
, vol.25
, pp. 1059-1070
-
-
Metz, C.E.1
Atkins, F.B.2
Beck, B.N.3
-
20
-
-
0025070160
-
The geometric transfer function for cone and fan beam collimators
-
B. M. W. Tsui and G. T. Gullberg, “The geometric transfer function for cone and fan beam collimators,” Phys. Med. Biol., vol. 35, pp. 81-93, 1990.
-
(1990)
Phys. Med. Biol.
, vol.35
, pp. 81-93
-
-
Tsui, B.M.W.1
Gullberg, G.T.2
|