Volumn 10, Issue 6, 2003, Pages 638-643

Measurement of the RT interval on ECG records during electron-beam CT

Author keywords

Computed tomography (CT), electron beam; Coronary vessels, calcification; Coronary vessels, CT

Indexed keywords

ADULT; AGED; ARTERY CALCIFICATION; ARTICLE; COMPUTER PROGRAM; CONTROLLED STUDY; CORONARY ARTERY DISEASE; CORRELATION COEFFICIENT; ELECTROCARDIOGRAM; ELECTRON BEAM TOMOGRAPHY; FEMALE; HEART FUNCTION; HEART RATE; HUMAN; LINEAR REGRESSION ANALYSIS; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; PR INTERVAL; PRIORITY JOURNAL; R WAVE; RR INTERVAL; SCREENING TEST; STATISTICAL ANALYSIS; SYSTOLE; T WAVE;

EID: 0038350964     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1076-6332(03)80082-X     Document Type: Article
Times cited : (15)

References (27)
  • 1
    • 0032884338 scopus 로고    scopus 로고
    • Electron beam computed tomography: Screening for coronary artery disease
    • Budoff M, Brundage BH. Electron beam computed tomography: screening for coronary artery disease. Clin Cardiol 1999; 22:554-558.
    • (1999) Clin Cardiol , vol.22 , pp. 554-558
    • Budoff, M.1    Brundage, B.H.2
  • 2
    • 0033013684 scopus 로고    scopus 로고
    • Electron computed tomographic coronary calcium scanning: A review and guidelines for use in asymptomatic persons
    • Rumberger J, Brundage BH, Rader DJ, et al. Electron computed tomographic coronary calcium scanning: a review and guidelines for use in asymptomatic persons. Mayo Clin Proc 1999; 74:243-252.
    • (1999) Mayo Clin Proc , vol.74 , pp. 243-252
    • Rumberger, J.1    Brundage, B.H.2    Rader, D.J.3
  • 3
    • 0032728134 scopus 로고    scopus 로고
    • Noninvasive evaluation of coronary artery bypass graft patency using three-dimensional angiography obtained with contrast-enhanced electron beam CT
    • Ha JW, Cho SY, Shim WH, et al. Noninvasive evaluation of coronary artery bypass graft patency using three-dimensional angiography obtained with contrast-enhanced electron beam CT. AJR Am J Roentgenol 1999; 172:1055-1059.
    • (1999) AJR Am J Roentgenol , vol.172 , pp. 1055-1059
    • Ha, J.W.1    Cho, S.Y.2    Shim, W.H.3
  • 4
    • 0031800903 scopus 로고    scopus 로고
    • Intravenous electron beam computed tomographic coronary artery angiography for segmental analysis of coronary artery stenoses
    • Schmermund A, Rensing BJ, Sheedy PF, et al. Intravenous electron beam computed tomographic coronary artery angiography for segmental analysis of coronary artery stenoses. J Am Coll Cardiol 1998; 31:1547-1554.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 1547-1554
    • Schmermund, A.1    Rensing, B.J.2    Sheedy, P.F.3
  • 5
    • 0031902962 scopus 로고    scopus 로고
    • Coronary artery stenoses: Assessment with contrast-enhanced electron-beam CT and axial reconstructions
    • Reddy GP, Chernoff DM, Adams JR, et al. Coronary artery stenoses: assessment with contrast-enhanced electron-beam CT and axial reconstructions. Radiology 1998; 208:167-172.
    • (1998) Radiology , vol.208 , pp. 167-172
    • Reddy, G.P.1    Chernoff, D.M.2    Adams, J.R.3
  • 6
    • 0036266152 scopus 로고    scopus 로고
    • Modified Blalock-Taussig shunt patency for pulmonary atresia: Assessment with electron beam CT
    • Okada M, Matsunaga N, Ito K, et al. Modified Blalock-Taussig shunt patency for pulmonary atresia: assessment with electron beam CT. J Comput Assist Tomogr 2002; 26:368-372.
    • (2002) J Comput Assist Tomogr , vol.26 , pp. 368-372
    • Okada, M.1    Matsunaga, N.2    Ito, K.3
  • 7
    • 0034867726 scopus 로고    scopus 로고
    • ECG-gated reconstructed multidetector row CT coronary angiography: Effect of varying trigger delay on image quality
    • Hong C, Becker CR, Huber A, et al. ECG-gated reconstructed multidetector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 2001; 220:712-717.
    • (2001) Radiology , vol.220 , pp. 712-717
    • Hong, C.1    Becker, C.R.2    Huber, A.3
  • 8
    • 0036935911 scopus 로고    scopus 로고
    • CT angiography of the coronary arteries with a 16-row spiral tomograph: Effect of spatial resolution on image quality
    • German
    • Jakobs TF, Becker CR, Wintersperger BJ, et al. CT angiography of the coronary arteries with a 16-row spiral tomograph: effect of spatial resolution on image quality. Radiologe 2002; 42:733-738. [German]
    • (2002) Radiologe , vol.42 , pp. 733-738
    • Jakobs, T.F.1    Becker, C.R.2    Wintersperger, B.J.3
  • 9
    • 0036580665 scopus 로고    scopus 로고
    • Multislice helical CT of the heart with retrospective ECG gating: Reduction of radiation exposure by ECG-controlled tube current modulation
    • Jakobs TF, Becker CR, Ohnesorge B, et al. Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 2002; 12:1081-1086.
    • (2002) Eur Radiol , vol.12 , pp. 1081-1086
    • Jakobs, T.F.1    Becker, C.R.2    Ohnesorge, B.3
  • 10
    • 0034097058 scopus 로고    scopus 로고
    • Three-dimensional, navigator-echo MR coronary angiography in detecting stenoses of the major epicardial vessels, with conventional coronary angiography as a standard of reference
    • Sardanelli F, Molinari G, Zandrino F, et al. Three-dimensional, navigator-echo MR coronary angiography in detecting stenoses of the major epicardial vessels, with conventional coronary angiography as a standard of reference. Radiology 2000; 214:808-814.
    • (2000) Radiology , vol.214 , pp. 808-814
    • Sardanelli, F.1    Molinari, G.2    Zandrino, F.3
  • 11
    • 0036435873 scopus 로고    scopus 로고
    • MRI of acute myocarditis: A comprehensive approach based on various imaging sequences
    • Laissy JP, Messin B, Varenne O, et al. MRI of acute myocarditis: a comprehensive approach based on various imaging sequences. Chest 2002; 122:1638-1648.
    • (2002) Chest , vol.122 , pp. 1638-1648
    • Laissy, J.P.1    Messin, B.2    Varenne, O.3
  • 12
    • 0036845522 scopus 로고    scopus 로고
    • Single-breathhold 3D-trueFISP cine cardiac imaging
    • Jung BA, Hennig J, Scheffler K. Single-breathhold 3D-trueFISP cine cardiac imaging. Magn Reson Med 2002; 48:921-925.
    • (2002) Magn Reson Med , vol.48 , pp. 921-925
    • Jung, B.A.1    Hennig, J.2    Scheffler, K.3
  • 13
    • 0034466393 scopus 로고    scopus 로고
    • Coronary artery motion and coronary artery imaging
    • Mao SS, Lu B, Budoff MJ, et al. Coronary artery motion and coronary artery imaging. J Comput Assist Tomogr 2000; 24:253-258.
    • (2000) J Comput Assist Tomogr , vol.24 , pp. 253-258
    • Mao, S.S.1    Lu, B.2    Budoff, M.J.3
  • 14
    • 0034767880 scopus 로고    scopus 로고
    • Optimal ECG trigger point in electronbeam CT studies: Three methods for minimizing motion artifacts
    • Mao SS, Budoff MJ, Lu B, et al. Optimal ECG trigger point in electronbeam CT studies: three methods for minimizing motion artifacts. Acad Radiol 2001; 8:1107-1115.
    • (2001) Acad Radiol , vol.8 , pp. 1107-1115
    • Mao, S.S.1    Budoff, M.J.2    Lu, B.3
  • 15
    • 0034953432 scopus 로고    scopus 로고
    • Improved reproducibility of coronary artery scoring by electron beam tomography with a new electrocardiographic trigger method
    • Mao SS, Budoff MJ, Bakhsheshi H, et al. Improved reproducibility of coronary artery scoring by electron beam tomography with a new electrocardiographic trigger method. Invest Radiol 2001; 36:363-367.
    • (2001) Invest Radiol , vol.36 , pp. 363-367
    • Mao, S.S.1    Budoff, M.J.2    Bakhsheshi, H.3
  • 16
    • 0034871404 scopus 로고    scopus 로고
    • Effect of electrocardiogram triggering on reproducibility of coronary artery calcium scoring
    • Mao SS, Bakhsheshi H, Lu B, et al. Effect of electrocardiogram triggering on reproducibility of coronary artery calcium scoring. Radiology 2001; 220:707-711.
    • (2001) Radiology , vol.220 , pp. 707-711
    • Mao, S.S.1    Bakhsheshi, H.2    Lu, B.3
  • 17
    • 0036720977 scopus 로고    scopus 로고
    • EKG-triggered CT data acquisition to reduce variability in coronary arterial calcium score
    • Lu B, Zhuang N, Mao SS, et al. EKG-triggered CT data acquisition to reduce variability in coronary arterial calcium score. Radiology 2002; 224:838-844.
    • (2002) Radiology , vol.224 , pp. 838-844
    • Lu, B.1    Zhuang, N.2    Mao, S.S.3
  • 18
    • 0036119542 scopus 로고    scopus 로고
    • Image quality of three-dimensional electron beam coronary angiography
    • Lu B, Zhuang N, Mao SS, et al. Image quality of three-dimensional electron beam coronary angiography. J Comput Assist Tomogr 2002; 26:202-209.
    • (2002) J Comput Assist Tomogr , vol.26 , pp. 202-209
    • Lu, B.1    Zhuang, N.2    Mao, S.S.3
  • 19
    • 0035025219 scopus 로고    scopus 로고
    • Coronary artery motion during the cardiac cycle and optimal ECG triggering for coronary artery imaging
    • Lu B, Mao SS, Zhuang N, et al. Coronary artery motion during the cardiac cycle and optimal ECG triggering for coronary artery imaging. Invest Radiol 2001; 36:250-256.
    • (2001) Invest Radiol , vol.36 , pp. 250-256
    • Lu, B.1    Mao, S.S.2    Zhuang, N.3
  • 20
    • 0033876932 scopus 로고    scopus 로고
    • In-plane coronary arterial motion velocity: Measurement with electron-beam CT
    • Achenbach S, Ropers D, Holle J, et al. In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology 2000; 216:457-463.
    • (2000) Radiology , vol.216 , pp. 457-463
    • Achenbach, S.1    Ropers, D.2    Holle, J.3
  • 26
    • 0030499835 scopus 로고    scopus 로고
    • Variation of heart rate and ECG trigger interval during ultrafast computed tomography
    • Mao SS, Oudiz RJ, Bakhsheshi H, Wang SJ, Brundage BH. Variation of heart rate and ECG trigger interval during ultrafast computed tomography. Am J Card Imaging 1996; 10:239-243.
    • (1996) Am J Card Imaging , vol.10 , pp. 239-243
    • Mao, S.S.1    Oudiz, R.J.2    Bakhsheshi, H.3    Wang, S.J.4    Brundage, B.H.5
  • 27
    • 0035984964 scopus 로고    scopus 로고
    • Causes of interscan variability of coronary artery calcium measurements at electron-beam CT
    • Lu B, Budoff MJ, Zhuang N, et al. Causes of interscan variability of coronary artery calcium measurements at electron-beam CT. Acad Radiol 2002; 9:654-661.
    • (2002) Acad Radiol , vol.9 , pp. 654-661
    • Lu, B.1    Budoff, M.J.2    Zhuang, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.