메뉴 건너뛰기




Volumn 148, Issue 6, 2003, Pages 1089-1093

Metal sensitivities and orthopaedic implants revisited: The potential for metal allergy with the new metal-on-metal joint prostheses

Author keywords

Aseptic loosening; Chromate; Cobalt; Joint replacement; Nickel allergy; Orthopaedic surgery; Polypropylene; Prostheses

Indexed keywords

CHROMIC ACID; COBALT; METAL; NICKEL; PLASTIC; POLYPROPYLENE;

EID: 0038346581     PISSN: 00070963     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-2133.2003.05404.x     Document Type: Review
Times cited : (101)

References (30)
  • 1
    • 0016820637 scopus 로고
    • Metal sensitivity in patients with joint replacement arthroplasties
    • Benson MKD, Goodwin PG, Brostoff J. Metal sensitivity in patients with joint replacement arthroplasties. Br Med J 1975; 4: 374-5.
    • (1975) Br Med J , vol.4 , pp. 374-375
    • Benson, M.K.D.1    Goodwin, P.G.2    Brostoff, J.3
  • 2
    • 0016718479 scopus 로고
    • Incidence of metal sensitivity in patients with total hip replacement
    • Elves MR, Wilson JN, Scales JT, Kemp HBS. Incidence of metal sensitivity in patients with total hip replacement. Br Med J 1975; 4: 376-8.
    • (1975) Br Med J , vol.4 , pp. 376-378
    • Elves, M.R.1    Wilson, J.N.2    Scales, J.T.3    Kemp, H.B.S.4
  • 3
    • 0017293230 scopus 로고
    • Rejection of metal to metal prosthesis and skin sensitivity to cobalt
    • Munro-Ashman D, Miller AJ. Rejection of metal to metal prosthesis and skin sensitivity to cobalt. Contact Dermatitis 1976; 2: 65-7.
    • (1976) Contact Dermatitis , vol.2 , pp. 65-67
    • Munro-Ashman, D.1    Miller, A.J.2
  • 5
    • 0033779480 scopus 로고    scopus 로고
    • Medium-term results of a modern metal-on-metal system in total hip replacement
    • Wagner M, Wagner H. Medium-term results of a modern metal-on-metal system in total hip replacement. Clin Orthop 2000; 379: 123-33.
    • (2000) Clin Orthop , vol.379 , pp. 123-133
    • Wagner, M.1    Wagner, H.2
  • 8
    • 0027232461 scopus 로고
    • Orthopaedic metallic implants in extremity fractures and contact allergy
    • Hindsen M, Carlsson AS, Moller H. Orthopaedic metallic implants in extremity fractures and contact allergy. J Eur Acad Dermatol Venereol 1993; 2: 22-6.
    • (1993) J Eur Acad Dermatol Venereol , vol.2 , pp. 22-26
    • Hindsen, M.1    Carlsson, A.S.2    Moller, H.3
  • 10
    • 0018758132 scopus 로고
    • Nickel allergy and osteomyelitis on a patient with metal osteosynthesis of a jaw fracture
    • Roed-Petersen B, Roed-Petersen J, Jorgensen KD. Nickel allergy and osteomyelitis on a patient with metal osteosynthesis of a jaw fracture. Contact Dermatitis 1979; 5: 108-12.
    • (1979) Contact Dermatitis , vol.5 , pp. 108-112
    • Roed-Petersen, B.1    Roed-Petersen, J.2    Jorgensen, K.D.3
  • 11
    • 84965270854 scopus 로고
    • Urticaria after insertion of Smith-Petersen Vitallium nail
    • McKenzie AW, Aitken CVE, Ridsdill-Smith R. Urticaria after insertion of Smith-Petersen Vitallium nail. Br Med J 1967; 4: 36.
    • (1967) Br Med J , vol.4 , pp. 36
    • McKenzie, A.W.1    Aitken, C.V.E.2    Ridsdill-Smith, R.3
  • 12
    • 0015528479 scopus 로고
    • Eczematous dermatitis from nickel
    • Barranco VP, Solomon H. Eczematous dermatitis from nickel. JAMA 1972; 220: 1244.
    • (1972) JAMA , vol.220 , pp. 1244
    • Barranco, V.P.1    Solomon, H.2
  • 13
    • 0029004245 scopus 로고
    • Allergic contact dermatitis from orthopaedic devices
    • Balato N, Costa L, Lembo G et al. Allergic contact dermatitis from orthopaedic devices. Contact Dermatitis 1995; 32: 314-15.
    • (1995) Contact Dermatitis , vol.32 , pp. 314-315
    • Balato, N.1    Costa, L.2    Lembo, G.3
  • 14
    • 0024591872 scopus 로고
    • Implantation of orthopaedic devices in patients with metal allergy
    • Carlsson A, Moller H. Implantation of orthopaedic devices in patients with metal allergy. Acta Derm Venereol (Stockh) 1989; 69: 62-6.
    • (1989) Acta Derm Venereol (Stockh) , vol.69 , pp. 62-66
    • Carlsson, A.1    Moller, H.2
  • 15
    • 0018890809 scopus 로고
    • Metal sensitivity in patients with metal-to-metal total hip arthroplasties
    • Carlsson AS, Magnusson B, Moller H. Metal sensitivity in patients with metal-to-metal total hip arthroplasties. Acta Orthop Scand 1980; 51: 57-62.
    • (1980) Acta Orthop Scand , vol.51 , pp. 57-62
    • Carlsson, A.S.1    Magnusson, B.2    Moller, H.3
  • 17
    • 0019451312 scopus 로고
    • Cutaneous complications of orthopedic implants
    • Kubba R, Taylor JS, Marks KE. Cutaneous complications of orthopedic implants. Arch Dermatol 1981; 117: 554-60.
    • (1981) Arch Dermatol , vol.117 , pp. 554-560
    • Kubba, R.1    Taylor, J.S.2    Marks, K.E.3
  • 18
    • 0019214001 scopus 로고
    • Metal sensitivity in patients undergoing hip replacement: A prospective study
    • Rooker GD, Wilkinson JD. Metal sensitivity in patients undergoing hip replacement: a prospective study. J Bone Joint Surg B 1980; 62: 502-5.
    • (1980) J Bone Joint Surg B , vol.62 , pp. 502-505
    • Rooker, G.D.1    Wilkinson, J.D.2
  • 19
    • 0029030285 scopus 로고
    • Investigation into the development of allergy to metal in recipients of implanted hip prostheses: A prospective study
    • Torok L, Greczy I, Ocsai H, Czako J. Investigation into the development of allergy to metal in recipients of implanted hip prostheses: a prospective study. Eur J Dermatol 1995; 5: 294-5.
    • (1995) Eur J Dermatol , vol.5 , pp. 294-295
    • Torok, L.1    Greczy, I.2    Ocsai, H.3    Czako, J.4
  • 20
    • 0026588199 scopus 로고
    • Is systemic nickel important?
    • Burrows D. Is systemic nickel important? J Am Acad Dermatol 1992; 26: 632-5.
    • (1992) J Am Acad Dermatol , vol.26 , pp. 632-635
    • Burrows, D.1
  • 21
    • 0032923862 scopus 로고    scopus 로고
    • Metal release and excretion from cementless titanium alloy total knee replacements
    • Jacobs JJ, Siverton C, Hallab NJ et al. Metal release and excretion from cementless titanium alloy total knee replacements. Clin Orthop 1999; 358: 173-80.
    • (1999) Clin Orthop , vol.358 , pp. 173-180
    • Jacobs, J.J.1    Siverton, C.2    Hallab, N.J.3
  • 22
    • 0019997918 scopus 로고
    • Metal concentration in synovial fluids of patients with prosthetic knee arthroplasty
    • Cracchiolo A, Revell P. Metal concentration in synovial fluids of patients with prosthetic knee arthroplasty. Clin Orthop 1982; 170: 169-74.
    • (1982) Clin Orthop , vol.170 , pp. 169-174
    • Cracchiolo, A.1    Revell, P.2
  • 23
    • 0028321408 scopus 로고
    • Particulate titanium and cobalt-chrome metallic debris in failed total knee arthroplasty. A quantitative histologic analysis
    • La Budde JK, Orosz JF, Bonfiglio TA, Pellegrini VD. Particulate titanium and cobalt-chrome metallic debris in failed total knee arthroplasty. A quantitative histologic analysis. J Arthroplasty 1994; 9: 291-304.
    • (1994) J Arthroplasty , vol.9 , pp. 291-304
    • La Budde, J.K.1    Orosz, J.F.2    Bonfiglio, T.A.3    Pellegrini, V.D.4
  • 24
    • 0027208262 scopus 로고
    • Extensive osteolysis around an aseptic, stable, uncemented total knee replacement
    • Berry DJ, Wold LE, Rand JA. Extensive osteolysis around an aseptic, stable, uncemented total knee replacement. Clin Orthop 1993; 293: 204-7.
    • (1993) Clin Orthop , vol.293 , pp. 204-207
    • Berry, D.J.1    Wold, L.E.2    Rand, J.A.3
  • 25
    • 0026058309 scopus 로고
    • Polyethylene failure of metal-backed patellar components. 111 AGC total knees followed for 7-22 months
    • Andersen HN, Ernst C, Frandsen PA. Polyethylene failure of metal-backed patellar components. 111 AGC total knees followed for 7-22 months. Acta Orthop Scand 1991; 62: 1-3.
    • (1991) Acta Orthop Scand , vol.62 , pp. 1-3
    • Andersen, H.N.1    Ernst, C.2    Frandsen, P.A.3
  • 26
    • 0030905094 scopus 로고    scopus 로고
    • Elevated serum cobalt with metal-on-metal articulating surfaces
    • Brodner W, Bitzan P, Meisinger V et al. Elevated serum cobalt with metal-on-metal articulating surfaces. J Bone Joint Surg B 1997; 79: 316-21.
    • (1997) J Bone Joint Surg B , vol.79 , pp. 316-321
    • Brodner, W.1    Bitzan, P.2    Meisinger, V.3
  • 27
    • 0031727764 scopus 로고    scopus 로고
    • Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study
    • Jacobs JJ, Skipor AK, Patterson LM et al. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am 1998; 80: 1447-58.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 1447-1458
    • Jacobs, J.J.1    Skipor, A.K.2    Patterson, L.M.3
  • 28
    • 0029813458 scopus 로고    scopus 로고
    • Contemporary total hip replacement with metal on metal articulation
    • Hilton KR, Dorr LD, Wan Z, McPherson EJ. Contemporary total hip replacement with metal on metal articulation. Clin Orthop 1996; 329 (Suppl.): S99-105.
    • (1996) Clin Orthop , vol.329 , Issue.SUPPL.
    • Hilton, K.R.1    Dorr, L.D.2    Wan, Z.3    McPherson, E.J.4
  • 30
    • 0037692030 scopus 로고    scopus 로고
    • Metal allergy resurfaces in failed hip endoprostheses
    • Abstr.
    • Antony F, Dudley W, Field R, Holden C. Metal allergy resurfaces in failed hip endoprostheses. Br J Dermatol 2001; 145 (Suppl. 59): 48 (Abstr.).
    • (2001) Br J Dermatol , vol.145 , Issue.SUPPL. 59 , pp. 48
    • Antony, F.1    Dudley, W.2    Field, R.3    Holden, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.