메뉴 건너뛰기




Volumn 76, Issue 1, 2003, Pages 58-64

Mechanical properties of porcine and human arteries: Implications for coronary anastomotic connectors

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANASTOMOSIS; ANIMAL TISSUE; ARTERIAL PRESSURE; ARTERY DIAMETER; ARTERY WALL; ARTICLE; CONTROLLED STUDY; CORONARY ARTERY; CORONARY ARTERY BYPASS GRAFT; ELASTICITY; EXPERIMENTAL MODEL; FEMALE; HUMAN; HUMAN TISSUE; INTERNAL MAMMARY ARTERY; MALE; NONHUMAN; NORMAL HUMAN; PARAMETER; PRIORITY JOURNAL; SPECIES DIFFERENTIATION; SWINE; THICKNESS;

EID: 0038337942     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0003-4975(03)00263-7     Document Type: Article
Times cited : (116)

References (26)
  • 1
    • 0033596967 scopus 로고    scopus 로고
    • Minimally invasive coronary artery bypass grafting: An experimental perspective
    • Borst C, Gründeman PF. Minimally invasive coronary artery bypass grafting: an experimental perspective. Circulation 1999;99:1400-3.
    • (1999) Circulation , vol.99 , pp. 1400-1403
    • Borst, C.1    Gründeman, P.F.2
  • 2
    • 0035353719 scopus 로고    scopus 로고
    • Computer-enhanced "robotic" cardiac surgery: Experience in 148 patients
    • Mohr FW, Falk V, Diegeler A, et al. Computer-enhanced "robotic" cardiac surgery: experience in 148 patients. J Thorac Cardiovasc Surg 2001;121:842-53.
    • (2001) J Thorac Cardiovasc Surg , vol.121 , pp. 842-853
    • Mohr, F.W.1    Falk, V.2    Diegeler, A.3
  • 3
    • 0033931588 scopus 로고    scopus 로고
    • Assessment of patented coronary end-to-side anastomotic devices using micromechanical bonding
    • Scheltes JS, Heikens M, Pistecky PV, van Andel CJ, Borst C. Assessment of patented coronary end-to-side anastomotic devices using micromechanical bonding. Ann Thorac Surg 2000;70:218-21.
    • (2000) Ann Thorac Surg , vol.70 , pp. 218-221
    • Scheltes, J.S.1    Heikens, M.2    Pistecky, P.V.3    Van Andel, C.J.4    Borst, C.5
  • 4
    • 85047680659 scopus 로고
    • A quantitative study of the anatomy and distribution of coronary arteries in swine in comparison with other animals and man
    • Weaver ME, Pantely GA, Bristow JD, Ladley HD. A quantitative study of the anatomy and distribution of coronary arteries in swine in comparison with other animals and man. Cardiovasc Res 1986;20:907-17.
    • (1986) Cardiovasc Res , vol.20 , pp. 907-917
    • Weaver, M.E.1    Pantely, G.A.2    Bristow, J.D.3    Ladley, H.D.4
  • 5
    • 0035856552 scopus 로고    scopus 로고
    • Intracoronary brachytherapy in the porcine model: A different animal
    • Fischell TA, Virmani R. Intracoronary brachytherapy in the porcine model: a different animal. Circulation 2001;104:2388-90.
    • (2001) Circulation , vol.104 , pp. 2388-2390
    • Fischell, T.A.1    Virmani, R.2
  • 6
    • 0025880348 scopus 로고
    • A piece-wise non-linear elastic stress expression of human and pig coronary arteries tested in vitro
    • Carmines DV, McElhaney JH, Stack R. A piece-wise non-linear elastic stress expression of human and pig coronary arteries tested in vitro. J Biomech 1991;24:899-906.
    • (1991) J Biomech , vol.24 , pp. 899-906
    • Carmines, D.V.1    McElhaney, J.H.2    Stack, R.3
  • 7
    • 0029952601 scopus 로고    scopus 로고
    • Effects of cryopreservation on the viscoelastic properties of human arteries
    • Rosset E, Friggi A, Novakovitch G, et al. Effects of cryopreservation on the viscoelastic properties of human arteries. Ann Vasc Surg 1996;10:262-72.
    • (1996) Ann Vasc Surg , vol.10 , pp. 262-272
    • Rosset, E.1    Friggi, A.2    Novakovitch, G.3
  • 8
    • 0030965393 scopus 로고    scopus 로고
    • Early rupture and degeneration of cryopreserved arterial allografts
    • Lehalle B, Geschier C, Fieve G, Stoltz JF. Early rupture and degeneration of cryopreserved arterial allografts. J Vasc Surg 1997;25:751-2.
    • (1997) J Vasc Surg , vol.25 , pp. 751-752
    • Lehalle, B.1    Geschier, C.2    Fieve, G.3    Stoltz, J.F.4
  • 9
    • 0034846009 scopus 로고    scopus 로고
    • Impact of current cryopreservation procedures on mechanical and functional properties of human aortic homografts
    • Langerak SE, Groenink M, van der Wall EE, et al. Impact of current cryopreservation procedures on mechanical and functional properties of human aortic homografts. Transpl Int 2001;14:248-55.
    • (2001) Transpl Int , vol.14 , pp. 248-255
    • Langerak, S.E.1    Groenink, M.2    Van Der Wall, E.E.3
  • 10
    • 0018606230 scopus 로고
    • The elasticity of canine and human coronary arteries with reference to postmortem changes
    • Gow BS, Hadfield CD. The elasticity of canine and human coronary arteries with reference to postmortem changes. Circ Res 1979;45:588-94.
    • (1979) Circ Res , vol.45 , pp. 588-594
    • Gow, B.S.1    Hadfield, C.D.2
  • 11
    • 0032191099 scopus 로고    scopus 로고
    • Changes in the mechanical properties, biochemical contents and wall structure of the human coronary arteries with age and sex
    • Ozolanta I, Tetere G, Purynya B, Kasyanov V. Changes in the mechanical properties, biochemical contents and wall structure of the human coronary arteries with age and sex. Med Eng Phys 1998;20:523-33.
    • (1998) Med Eng Phys , vol.20 , pp. 523-533
    • Ozolanta, I.1    Tetere, G.2    Purynya, B.3    Kasyanov, V.4
  • 12
    • 0004376035 scopus 로고
    • Pseudoelasticity of arteries and the choice of its mathematical expression
    • Fung YC, Fronek K, Patitucci P. Pseudoelasticity of arteries and the choice of its mathematical expression. Am J Physiol 1979;237:H620-31.
    • (1979) Am J Physiol , vol.237
    • Fung, Y.C.1    Fronek, K.2    Patitucci, P.3
  • 13
    • 0003168036 scopus 로고
    • Mechanical properties and active remodeling of blood vessels
    • New York: Springer-Verlag
    • Fung YC. Mechanical properties and active remodeling of blood vessels. In: Biomechanics: mechanical properties of living tissues. New York: Springer-Verlag, 1993:321-91.
    • (1993) Biomechanics: Mechanical Properties of Living Tissues , pp. 321-391
    • Fung, Y.C.1
  • 14
    • 0022385635 scopus 로고
    • Twelve-year experience with internal mammary artery for coronary artery bypass
    • Barner HB, Standeven JW, Reese J. Twelve-year experience with internal mammary artery for coronary artery bypass. J Thorac Cardiovasc Surg 1985;90:668-75.
    • (1985) J Thorac Cardiovasc Surg , vol.90 , pp. 668-675
    • Barner, H.B.1    Standeven, J.W.2    Reese, J.3
  • 15
    • 0030214496 scopus 로고    scopus 로고
    • A new axisymmetrical membrane element for anisotropic, finite strain analysis of arteries
    • Holzapfel GA, Eberlein R, Wriggers P, Weizsäcker HW. A new axisymmetrical membrane element for anisotropic, finite strain analysis of arteries. Commun Numer Meth En 1996;12:507-17.
    • (1996) Commun Numer Meth En , vol.12 , pp. 507-517
    • Holzapfel, G.A.1    Eberlein, R.2    Wriggers, P.3    Weizsäcker, H.W.4
  • 17
    • 0025313078 scopus 로고
    • Internal elastic membrane in the internal mammary and left anterior descending coronary arteries and its relation to intimal thickening
    • Svendson E, Dregelid E, Eide GE. Internal elastic membrane in the internal mammary and left anterior descending coronary arteries and its relation to intimal thickening. Atherosclerosis 1990;83:239-49.
    • (1990) Atherosclerosis , vol.83 , pp. 239-249
    • Svendson, E.1    Dregelid, E.2    Eide, G.E.3
  • 18
    • 0027197678 scopus 로고
    • Contractility of the human internal mammary artery at the distal section increases towards the end. Emphasis on not using the end of the internal mammary artery for grafting
    • He GW. Contractility of the human internal mammary artery at the distal section increases towards the end. Emphasis on not using the end of the internal mammary artery for grafting. J Thorac Cardiovasc Surg 1993;106:406-11.
    • (1993) J Thorac Cardiovasc Surg , vol.106 , pp. 406-411
    • He, G.W.1
  • 19
    • 17544403187 scopus 로고    scopus 로고
    • Comparative reactivity and mechanical properties of human isolated internal mammary and radial arteries
    • Chamiot-Clerc P, Copie X, Renaud J-F, Safar M, Girerd X. Comparative reactivity and mechanical properties of human isolated internal mammary and radial arteries. Cardiovasc Res 1998;37:811-9.
    • (1998) Cardiovasc Res , vol.37 , pp. 811-819
    • Chamiot-Clerc, P.1    Copie, X.2    Renaud, J.-F.3    Safar, M.4    Girerd, X.5
  • 21
    • 0042200767 scopus 로고    scopus 로고
    • Compliance mismatch may promote graft-artery intimal hyperplasia by altering suture-line stresses
    • Ballyk PD, Walsh C, Butany J, Ojha M. Compliance mismatch may promote graft-artery intimal hyperplasia by altering suture-line stresses. J Biomech 1998;31:229-37.
    • (1998) J Biomech , vol.31 , pp. 229-237
    • Ballyk, P.D.1    Walsh, C.2    Butany, J.3    Ojha, M.4
  • 22
    • 0028808319 scopus 로고
    • Compliance mismatch and formation of distal anastomotic intimal hyperplasia in externally stiffened and lumen-adapted venous grafts
    • Trubel W, Schima H, Moritz A, et al. Compliance mismatch and formation of distal anastomotic intimal hyperplasia in externally stiffened and lumen-adapted venous grafts. Eur J Vasc Endovasc Surg 1995;10:415-23.
    • (1995) Eur J Vasc Endovasc Surg , vol.10 , pp. 415-423
    • Trubel, W.1    Schima, H.2    Moritz, A.3
  • 23
    • 0002832470 scopus 로고
    • Mechanical properties of arteries and arterial grafts
    • Hastings GW, ed. London: Springer-Verlag
    • How TV. Mechanical properties of arteries and arterial grafts. In: Hastings GW, ed. Cardiovascular biomaterials. London: Springer-Verlag, 1992:1-35.
    • (1992) Cardiovascular Biomaterials , pp. 1-35
    • How, T.V.1
  • 25
    • 0034843748 scopus 로고    scopus 로고
    • Is the GraftConnector a valid alternative to running suture in end-to-side coronary arteries anastomosis?
    • Tozzi P, Solem JO, Boumzebra D, et al. Is the GraftConnector a valid alternative to running suture in end-to-side coronary arteries anastomosis? Ann Thorac Surg 2001;72:S999-1003.
    • (2001) Ann Thorac Surg , vol.72
    • Tozzi, P.1    Solem, J.O.2    Boumzebra, D.3
  • 26
    • 0036189143 scopus 로고    scopus 로고
    • An experimental model of saphenous vein-to-coronary artery anastomosis with the St. Jude Medical stainless steel connector
    • Schaff HV, Zehr KJ, Bonilla LF, et al. An experimental model of saphenous vein-to-coronary artery anastomosis with the St. Jude Medical stainless steel connector. Ann Thorac Surg 2002;73:830-6.
    • (2002) Ann Thorac Surg , vol.73 , pp. 830-836
    • Schaff, H.V.1    Zehr, K.J.2    Bonilla, L.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.