1
-
-
0024495078
-
Leaflet fracture in Edwards-Duromedics bileaflet valves
-
Klepetko W, Moritz A, Mlczoch J, Schurawitzki H, Domanig E, Wolner E. Leaflet fracture in Edwards-Duromedics bileaflet valves. J Thorac Cardiovasc Surg 1989;97:90-94
-
(1989)
J Thorac Cardiovasc Surg
, vol.97
, pp. 90-94
-
-
Klepetko, W.1
Moritz, A.2
Mlczoch, J.3
Schurawitzki, H.4
Domanig, E.5
Wolner, E.6
-
2
-
-
0028216521
-
Causes and formation of cavitation in mechanical heart valve
-
Graf T, Reul H, Detlefs C, Wilmes R, Rau G. Causes and formation of cavitation in mechanical heart valve. J Heart Valve Dis 1994;3(suppl 1):S49-S64
-
(1994)
J Heart Valve Dis
, vol.3
, Issue.SUPPL. 1
-
-
Graf, T.1
Reul, H.2
Detlefs, C.3
Wilmes, R.4
Rau, G.5
-
3
-
-
0028287316
-
In vitro observations of mechanical heart valve cavitation
-
Shu MCS, Leuer LH, Armitage TL, Schneider TE, Christiansen DR. In vitro observations of mechanical heart valve cavitation. J Heart Valve Dis 1994;3(suppl I):S85-S93
-
(1994)
J Heart Valve Dis
, vol.3
, Issue.SUPPL. I
-
-
Shu, M.C.S.1
Leuer, L.H.2
Armitage, T.L.3
Schneider, T.E.4
Christiansen, D.R.5
-
4
-
-
0027943765
-
Cavitation dynamics of mechanical heart valve prostheses
-
Lee CS, Chandran KB, Chen LD. Cavitation dynamics of mechanical heart valve prostheses. Artif Organs 1994;18:758-767
-
(1994)
Artif Organs
, vol.18
, pp. 758-767
-
-
Lee, C.S.1
Chandran, K.B.2
Chen, L.D.3
-
5
-
-
0028298260
-
Occluder closing behavior: A key factor in mechanical heart valve cavitation
-
Wu ZJ, Wang Y, Hwang NHC. Occluder closing behavior: a key factor in mechanical heart valve cavitation. J Heart Valve Dis 1994:3(suppl I):S25-S34
-
(1994)
J Heart Valve Dis
, vol.3
, Issue.SUPPL. I
-
-
Wu, Z.J.1
Wang, Y.2
Hwang, N.H.C.3
-
6
-
-
0003731071
-
-
Iowa City, IA, USA: Institute of Hydraulic Research, University of Iowa
-
Knapp RT, Daily JW, Hammitt FG. Cavitation. Iowa City, IA, USA: Institute of Hydraulic Research, University of Iowa, 1979
-
(1979)
Cavitation
-
-
Knapp, R.T.1
Daily, J.W.2
Hammitt, F.G.3
-
8
-
-
0028533807
-
A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis
-
Bluestein D, Einav S, Hwang NHC. A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis. J Biomech 1994;27:1369-1378
-
(1994)
J Biomech
, vol.27
, pp. 1369-1378
-
-
Bluestein, D.1
Einav, S.2
Hwang, N.H.C.3
-
9
-
-
0034566379
-
Surface pitting of heart valve disks tested in an accelerated fatigue tester
-
Lee HS, Shimooka T, Mitamura Y, Tamamoto K, Yuhta T. Surface pitting of heart valve disks tested in an accelerated fatigue tester. Frontiers Med Biol Eng 2000;10:167-176
-
(2000)
Frontiers Med Biol Eng
, vol.10
, pp. 167-176
-
-
Lee, H.S.1
Shimooka, T.2
Mitamura, Y.3
Tamamoto, K.4
Yuhta, T.5
-
10
-
-
0031238497
-
Early changes in circulating blood volume and volume regulating humoral factors after implantation of an electrohydraulic total implantable artificial heart
-
Nakamura M, Tatsumi E, Masuzawa T, Taenaka Y, Nakatani T, Sohn Y, Endo S, Ohino T, Takiura K, Nishimura T, Takewa Y, Wakisaka Y, Takano H. Early changes in circulating blood volume and volume regulating humoral factors after implantation of an electrohydraulic total implantable artificial heart. ASAIO J 1997;43:M663-M668
-
(1997)
ASAIO J
, vol.43
-
-
Nakamura, M.1
Tatsumi, E.2
Masuzawa, T.3
Taenaka, Y.4
Nakatani, T.5
Sohn, Y.6
Endo, S.7
Ohino, T.8
Takiura, K.9
Nishimura, T.10
Takewa, Y.11
Wakisaka, Y.12
Takano, H.13
-
11
-
-
0032170919
-
Characterization and optimization of the flow pattern inside a diaphragm blood pump based on flow visualization techniques
-
Nakata M, Masuzawa T, Tatsumi E, Taenaka Y, Nishimura T, Tsukiya T, Takano H, Tsuchimoto K, Ohiba K. Characterization and optimization of the flow pattern inside a diaphragm blood pump based on flow visualization techniques. ASAIO J 1998;44:M714-M718
-
(1998)
ASAIO J
, vol.44
-
-
Nakata, M.1
Masuzawa, T.2
Tatsumi, E.3
Taenaka, Y.4
Nishimura, T.5
Tsukiya, T.6
Takano, H.7
Tsuchimoto, K.8
Ohiba, K.9
|