메뉴 건너뛰기




Volumn 6, Issue 1, 2003, Pages 37-41

Closing behavior of the mechanical heart valve in a total artificial heart

Author keywords

Cavitation threshold; Closing behavior; Mechanical heart valve; Total artificial heart

Indexed keywords

ARTICLE; ARTIFICIAL HEART; BIOMECHANICS; CAVITATION; FRACTURE; HEART ATRIUM PRESSURE; HEART OUTPUT; HEART PRELOAD; HEART RATE; HEART STROKE VOLUME; HEART VALVE PROSTHESIS; HEMODYNAMICS; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; SIMULATION; VELOCITY; WOUND CLOSURE;

EID: 0038333498     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s100470300006     Document Type: Article
Times cited : (6)

References (11)
  • 2
    • 0028216521 scopus 로고
    • Causes and formation of cavitation in mechanical heart valve
    • Graf T, Reul H, Detlefs C, Wilmes R, Rau G. Causes and formation of cavitation in mechanical heart valve. J Heart Valve Dis 1994;3(suppl 1):S49-S64
    • (1994) J Heart Valve Dis , vol.3 , Issue.SUPPL. 1
    • Graf, T.1    Reul, H.2    Detlefs, C.3    Wilmes, R.4    Rau, G.5
  • 4
    • 0027943765 scopus 로고
    • Cavitation dynamics of mechanical heart valve prostheses
    • Lee CS, Chandran KB, Chen LD. Cavitation dynamics of mechanical heart valve prostheses. Artif Organs 1994;18:758-767
    • (1994) Artif Organs , vol.18 , pp. 758-767
    • Lee, C.S.1    Chandran, K.B.2    Chen, L.D.3
  • 5
    • 0028298260 scopus 로고
    • Occluder closing behavior: A key factor in mechanical heart valve cavitation
    • Wu ZJ, Wang Y, Hwang NHC. Occluder closing behavior: a key factor in mechanical heart valve cavitation. J Heart Valve Dis 1994:3(suppl I):S25-S34
    • (1994) J Heart Valve Dis , vol.3 , Issue.SUPPL. I
    • Wu, Z.J.1    Wang, Y.2    Hwang, N.H.C.3
  • 6
    • 0003731071 scopus 로고
    • Iowa City, IA, USA: Institute of Hydraulic Research, University of Iowa
    • Knapp RT, Daily JW, Hammitt FG. Cavitation. Iowa City, IA, USA: Institute of Hydraulic Research, University of Iowa, 1979
    • (1979) Cavitation
    • Knapp, R.T.1    Daily, J.W.2    Hammitt, F.G.3
  • 8
    • 0028533807 scopus 로고
    • A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis
    • Bluestein D, Einav S, Hwang NHC. A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis. J Biomech 1994;27:1369-1378
    • (1994) J Biomech , vol.27 , pp. 1369-1378
    • Bluestein, D.1    Einav, S.2    Hwang, N.H.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.