메뉴 건너뛰기




Volumn 14, Issue 4, 2003, Pages 295-301

Determination of carbon isotope ratios in amino acids, proteins, and oligosaccharides by inductively coupled plasma-mass spectrometry

Author keywords

[No Author keywords available]

Indexed keywords

AMINO ACIDS; CARBON; ISOTOPES; MASS SPECTROMETRY; OLIGOMERS; PROTEINS;

EID: 0038313006     PISSN: 10440305     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1044-0305(03)00003-5     Document Type: Article
Times cited : (24)

References (32)
  • 1
    • 0028383712 scopus 로고
    • Occurrence and Reduction of Noise in ICP-MS for Enhanced Precision in Isotope Ratio Measurement
    • Begley I., Sharp B.L. Occurrence and Reduction of Noise in ICP-MS for Enhanced Precision in Isotope Ratio Measurement. J. Anal. Atomic Spectrom. 9:1994;171-176.
    • (1994) J. Anal. Atomic Spectrom. , vol.9 , pp. 171-176
    • Begley, I.1    Sharp, B.L.2
  • 2
    • 37049080380 scopus 로고
    • Optimization of Mass Scanning Rate for Determination of Lead Isotope Ratios Using an ICP-MS
    • Furuta N. Optimization of Mass Scanning Rate for Determination of Lead Isotope Ratios Using an ICP-MS. J. Anal. Atomic Spectrom. 6:1991;199-207.
    • (1991) J. Anal. Atomic Spectrom. , vol.6 , pp. 199-207
    • Furuta, N.1
  • 3
    • 0000303273 scopus 로고
    • Verification of a Correction Procedure for Measurement of Pb Isotope Ratios by ICPMS
    • Ketterer M.E., Peters M.J., Tisdale P.J. Verification of a Correction Procedure for Measurement of Pb Isotope Ratios by ICPMS. J. Anal. Atomic Spectrom. 6:1991;439-443.
    • (1991) J. Anal. Atomic Spectrom. , vol.6 , pp. 439-443
    • Ketterer, M.E.1    Peters, M.J.2    Tisdale, P.J.3
  • 5
    • 0002660553 scopus 로고
    • Isotope Ratio Measurement by ICP Multicollector MS Incorporating a High Efficiency Nebulization System
    • Walder A.J., Koller D., Reed N.M., Hutton R.C., Freedman P.A. Isotope Ratio Measurement by ICP Multicollector MS Incorporating a High Efficiency Nebulization System. J. Anal. Atomic Spectrom. 8:1993;1037-1042.
    • (1993) J. Anal. Atomic Spectrom. , vol.8 , pp. 1037-1042
    • Walder, A.J.1    Koller, D.2    Reed, N.M.3    Hutton, R.C.4    Freedman, P.A.5
  • 7
    • 0028543066 scopus 로고
    • Simultaneous Measurement of Ion Ratios by ICP-MS with a Twin Quadrupole Instrument
    • Warren A.R., Allen L.A., Pang H.M., Houk R.S., Janghorbani M. Simultaneous Measurement of Ion Ratios by ICP-MS with a Twin Quadrupole Instrument. Appl. Spectrosc. 48:1994;1360-1366.
    • (1994) Appl. Spectrosc. , vol.48 , pp. 1360-1366
    • Warren, A.R.1    Allen, L.A.2    Pang, H.M.3    Houk, R.S.4    Janghorbani, M.5
  • 8
    • 0000521956 scopus 로고
    • Simultaneous Measurement of Isotope Ratios in Solids by Laser Ablation with a Twin Quadrupole ICP-MS
    • Allen L.A., Pang H.M., Warren A.R., Houk R.S. Simultaneous Measurement of Isotope Ratios in Solids by Laser Ablation with a Twin Quadrupole ICP-MS. J. Anal. Atomic Spectrom. 10:1995;267-271.
    • (1995) J. Anal. Atomic Spectrom. , vol.10 , pp. 267-271
    • Allen, L.A.1    Pang, H.M.2    Warren, A.R.3    Houk, R.S.4
  • 9
    • 0031071519 scopus 로고    scopus 로고
    • Precise Measurement of Ion Ratios in Solids Using Laser Ablation ICP-MS with a Twin Quadrupole Instrument
    • Allen L.A., Leach J.J., Pang H.M., Houk R.S. Precise Measurement of Ion Ratios in Solids Using Laser Ablation ICP-MS with a Twin Quadrupole Instrument. J. Anal. Atomic Spectrom. 12:1997;171-176.
    • (1997) J. Anal. Atomic Spectrom. , vol.12 , pp. 171-176
    • Allen, L.A.1    Leach, J.J.2    Pang, H.M.3    Houk, R.S.4
  • 10
    • 0001914863 scopus 로고
    • Mass Spectrometry of ICPs
    • Houk R.S. Mass Spectrometry of ICPs. Anal. Chem. 58:1986;97A-105A.
    • (1986) Anal. Chem. , vol.58
    • Houk, R.S.1
  • 11
    • 0001617098 scopus 로고    scopus 로고
    • Determination of Heavy Metal Complexes with Humic Substances by HPLC/ICP-MS Using On-line Isotope Dilution Technique
    • Vogl J., Heumann K.G. Determination of Heavy Metal Complexes with Humic Substances by HPLC/ICP-MS Using On-line Isotope Dilution Technique. Fresenius J. Anal. Chem. 359:1997;438-441.
    • (1997) Fresenius J. Anal. Chem. , vol.359 , pp. 438-441
    • Vogl, J.1    Heumann, K.G.2
  • 12
    • 0000829015 scopus 로고    scopus 로고
    • Development of an ICP-IDMS Method for Dissolved Organic Carbon Determinations and Its Application to Chromatographic Fractions of Heavy Metal Complexes with Humic Substances
    • Vogl J., Heumann K.G. Development of an ICP-IDMS Method for Dissolved Organic Carbon Determinations and Its Application to Chromatographic Fractions of Heavy Metal Complexes with Humic Substances. Anal. Chem. 70:1998;2038-2043.
    • (1998) Anal. Chem. , vol.70 , pp. 2038-2043
    • Vogl, J.1    Heumann, K.G.2
  • 13
    • 0030455175 scopus 로고    scopus 로고
    • GC/GC/C/IRMS System for Carbon Isotope Measurement of Low Level Methane Concentration
    • Sugimoto A. GC/GC/C/IRMS System for Carbon Isotope Measurement of Low Level Methane Concentration. Geochem. J. 30:1996;195-200.
    • (1996) Geochem. J. , vol.30 , pp. 195-200
    • Sugimoto, A.1
  • 15
    • 2842517944 scopus 로고    scopus 로고
    • Potential of GC- Isotope Ratio MS to Source Polynuclear Aromatic Hydrocarbon Emission
    • McRae C., Love G.D., Murray I.P., Snape C.E., Fallick A.E. Potential of GC- Isotope Ratio MS to Source Polynuclear Aromatic Hydrocarbon Emission. Anal. Commun. 33:1996;331-335.
    • (1996) Anal. Commun. , vol.33 , pp. 331-335
    • McRae, C.1    Love, G.D.2    Murray, I.P.3    Snape, C.E.4    Fallick, A.E.5
  • 17
    • 0030175519 scopus 로고    scopus 로고
    • Isotopic Differences in Human Growth Hormone Preparations
    • Abramson F.P., Osborn B.L., Teffera Y. Isotopic Differences in Human Growth Hormone Preparations. Anal. Chem. 68:1996;1971-1972.
    • (1996) Anal. Chem. , vol.68 , pp. 1971-1972
    • Abramson, F.P.1    Osborn, B.L.2    Teffera, Y.3
  • 18
    • 0000081066 scopus 로고
    • Determination of Concentration and Carbon Isotopic Composition of Dissolved Methane in Sediments and Nearshore Waters
    • Popp B.N., Sansone F.J., Rust T.M., Merritt D.A. Determination of Concentration and Carbon Isotopic Composition of Dissolved Methane in Sediments and Nearshore Waters. Anal. Chem. 67:1995;405-411.
    • (1995) Anal. Chem. , vol.67 , pp. 405-411
    • Popp, B.N.1    Sansone, F.J.2    Rust, T.M.3    Merritt, D.A.4
  • 19
    • 0003017507 scopus 로고    scopus 로고
    • Stable Carbon Isotopic Analysis of Low-Level Methane in Water and Gas
    • Sansone F.J., Popp B.N., Rust T.M. Stable Carbon Isotopic Analysis of Low-Level Methane in Water and Gas. Anal. Chem. 69:1997;40-44.
    • (1997) Anal. Chem. , vol.69 , pp. 40-44
    • Sansone, F.J.1    Popp, B.N.2    Rust, T.M.3
  • 20
    • 0001445164 scopus 로고
    • Isotope Ratio Monitoring GC-MS
    • Matthew D.E., Hayes J.M. Isotope Ratio Monitoring GC-MS. Anal. Chem. 50:1978;1465-1473.
    • (1978) Anal. Chem. , vol.50 , pp. 1465-1473
    • Matthew, D.E.1    Hayes, J.M.2
  • 22
    • 0024032920 scopus 로고
    • Alleviation of Spectral Overlap Interferences for Determination of Isotope Ratios of Potassium by ICP-MS
    • Jiang S.-J., Stevens M., Houk R.S. Alleviation of Spectral Overlap Interferences for Determination of Isotope Ratios of Potassium by ICP-MS. Anal. Chem. 60:1988;1217.
    • (1988) Anal. Chem. , vol.60 , pp. 1217
    • Jiang, S.-J.1    Stevens, M.2    Houk, R.S.3
  • 23
    • 3242778130 scopus 로고
    • Characterization of Ionization and Matrix Suppression in Inductively Coupled "Cold" Plasma MS
    • Tanner S.D. Characterization of Ionization and Matrix Suppression in Inductively Coupled "Cold" Plasma MS. J. Anal. Atomic Spectrom. 10:1995;905-921.
    • (1995) J. Anal. Atomic Spectrom. , vol.10 , pp. 905-921
    • Tanner, S.D.1
  • 24
    • 0028514552 scopus 로고
    • Reduction of Fundamental Polyatomic Ions in ICP-MS
    • Sakata K., Kawabata K. Reduction of Fundamental Polyatomic Ions in ICP-MS. Spectrochim. Acta Part B. 49:1994;1027-1038.
    • (1994) Spectrochim. Acta Part B , vol.49 , pp. 1027-1038
    • Sakata, K.1    Kawabata, K.2
  • 26
    • 85031161482 scopus 로고    scopus 로고
    • Ph.D. Thesis, Iowa State University
    • Luong, E. T. Ph.D. Thesis, Iowa State University, 1999 pp 71-84.
    • (1999) , pp. 71-84
    • Luong, E.T.1
  • 27
    • 0002618006 scopus 로고
    • Analytical Characteristics of a New, Offset Ion Lens for ICP-MS. I. Ion Trajectories and Detector Performance
    • Hu K., Clemons P.S., Houk R.S. Analytical Characteristics of a New, Offset Ion Lens for ICP-MS. I. Ion Trajectories and Detector Performance. J. Am. Soc. Mass Spectrom. 4:1993;16-27.
    • (1993) J. Am. Soc. Mass Spectrom. , vol.4 , pp. 16-27
    • Hu, K.1    Clemons, P.S.2    Houk, R.S.3
  • 30
    • 0037023111 scopus 로고    scopus 로고
    • Comparative Study of the Determination of Equilibrium Dissociation Temperature in ICP-MS
    • Evans E.H., Ebdon L., Rowley L. Comparative Study of the Determination of Equilibrium Dissociation Temperature in ICP-MS. Spectrochim. Acta Part B. 57:2002;741-747.
    • (2002) Spectrochim. Acta Part B , vol.57 , pp. 741-747
    • Evans, E.H.1    Ebdon, L.2    Rowley, L.3
  • 32
    • 0031246851 scopus 로고    scopus 로고
    • A High Speed Photographic Study of Wet Droplets and Solid Particles in an ICP
    • Houk R.S., Winge R.K., Chen X. A High Speed Photographic Study of Wet Droplets and Solid Particles in an ICP. J. Anal. Atomic Spectrom. 12:1997;1139-1148.
    • (1997) J. Anal. Atomic Spectrom. , vol.12 , pp. 1139-1148
    • Houk, R.S.1    Winge, R.K.2    Chen, X.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.