메뉴 건너뛰기




Volumn 7, Issue 2, 2003, Pages 225-231

Long-term catheters for apheresis and dialysis with surface treatment with infection resistance and low thrombogenicity

Author keywords

Large bore catheters; Microdomain surfaces; Spi Argent; Spi Silicone; Surface treated catheters

Indexed keywords

SILICONE; SILVER;

EID: 0038307300     PISSN: 10916660     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1526-0968.2003.00042.x     Document Type: Article
Times cited : (14)

References (42)
  • 1
    • 0037835908 scopus 로고
    • Haemodialysis by percutaneous catheterization of the femoral artery and vein with regional heparinization
    • Shaldon S, Chainduni L, Higgs B. Haemodialysis by percutaneous catheterization of the femoral artery and vein with regional heparinization. Lancet 1981;II;867.
    • (1981) Lancet , vol.2 , pp. 867
    • Shaldon, S.1    Chainduni, L.2    Higgs, B.3
  • 2
    • 0001823044 scopus 로고
    • Behandlung der diuretikaresistenten überwässerung mit arteriovenöser hämofiltration
    • Scheler F, Von Hennings HV. eds. München-Deisenhofen: Dustri-Verlag
    • Kramer P, Langenscheid C, Matthei D, Rieger J. Behandlung der Diuretikaresistenten Überwässerung Mit Arteriovenöser Hämofiltration. In: Scheler F, Von Hennings HV. eds. Haemofiltration München-Deisenhofen: Dustri-Verlag, 1977;23-8.
    • (1977) Haemofiltration Filtration , pp. 23-28
    • Kramer, P.1    Langenscheid, C.2    Matthei, D.3    Rieger, J.4
  • 3
    • 0003096265 scopus 로고
    • Möglichkeiten des temporären gefäßzugangs
    • Schwarzbeck A. Möglichkeiten des temporären Gefäßzugangs. Mitt Klin Nephrologie 1983;12:65.
    • (1983) Mitt Klin Nephrologie , vol.12 , pp. 65
    • Schwarzbeck, A.1
  • 4
    • 0020427089 scopus 로고
    • Transcutaneous insertion of the Shaldon catheter through the internal jugular vein as access for acute hemodialysis
    • Bambauer R, Jutzler GA. Transcutaneous insertion of the Shaldon catheter through the internal jugular vein as access for acute hemodialysis. Dial Transplant 1982;11:766.
    • (1982) Dial Transplant , vol.11 , pp. 766
    • Bambauer, R.1    Jutzler, G.A.2
  • 5
    • 0003129393 scopus 로고
    • Infections due to infusion therapy
    • Bennett IV, Brachman PS, eds. Boston: Little Brown.
    • Maki DG. Infections Due to Infusion Therapy. In: Bennett IV, Brachman PS, eds. Hospital infections: Boston: Little Brown. 1992;849-58.
    • (1992) Hospital Infections , pp. 849-858
    • Maki, D.G.1
  • 7
    • 0027377706 scopus 로고
    • Infectious morbidity associated with long-term use of venous access devices in patients with cancer
    • Groeger JS, Lucas AB, Thaler HT. Infectious morbidity associated with long-term use of venous access devices in patients with cancer. Ann Intern Med 1993;119:1168-74.
    • (1993) Ann Intern Med , vol.119 , pp. 1168-1174
    • Groeger, J.S.1    Lucas, A.B.2    Thaler, H.T.3
  • 8
    • 0026606102 scopus 로고
    • Frequency, therapy and prevention of infections associated with large-bore catheter
    • Bambauer R, Mestres P, Pirrung KJ. Frequency, therapy and prevention of infections associated with large-bore catheter. ASAIO J 1992;38:96-101.
    • (1992) ASAIO J , vol.38 , pp. 96-101
    • Bambauer, R.1    Mestres, P.2    Pirrung, K.J.3
  • 9
    • 0002818403 scopus 로고
    • Side effects and infections associated with large-bore catheters for extracorporeal detoxification methods
    • Bambauer R, Mestres P, Pirrung KJ. Side effects and infections associated with large-bore catheters for extracorporeal detoxification methods. ECC Int 1994;6:5-19.
    • (1994) ECC Int , vol.6 , pp. 5-19
    • Bambauer, R.1    Mestres, P.2    Pirrung, K.J.3
  • 10
    • 0019370746 scopus 로고
    • Microbiological colonization of prosthetic devises. Microtopological characteristics of intravenous catheters as detected by Scanning Electron Microscopy
    • Locci R, Peters G, Pulverer G. Microbiological colonization of prosthetic devises. Microtopological characteristics of intravenous catheters as detected by Scanning Electron Microscopy. Zentralbl Bakterial Mikrobiol Hyg 1981;173:285-92.
    • (1981) Zentralbl Bakterial Mikrobiol Hyg , vol.173 , pp. 285-292
    • Locci, R.1    Peters, G.2    Pulverer, G.3
  • 12
    • 0027082732 scopus 로고
    • Central venous catheters for apheresis access
    • Thompson L. Central venous catheters for apheresis access. J Clin Apheresis 1992;7:154-7.
    • (1992) J Clin Apheresis , vol.7 , pp. 154-157
    • Thompson, L.1
  • 13
    • 0031282625 scopus 로고    scopus 로고
    • Use of double-lumen dialysis catheters loading with iocked heparin
    • Hariprasad ST, Zbvlut JT. Use of double-lumen dialysis catheters loading with iocked heparin ASAIO J 1997;43:900-3.
    • (1997) ASAIO J , vol.43 , pp. 900-903
    • Hariprasad, S.T.1    Zbvlut, J.T.2
  • 14
    • 12944317149 scopus 로고    scopus 로고
    • Venous stenous and thrombosis associated with the use of internal jugular vein catheters for Hemodialysis
    • Jassal SV, Pieratos A, Roscoe JM. Venous stenous and thrombosis associated with the use of internal jugular vein catheters for Hemodialysis ASAIO J 1999;45:356-9.
    • (1999) ASAIO J , vol.45 , pp. 356-359
    • Jassal, S.V.1    Pieratos, A.2    Roscoe, J.M.3
  • 15
    • 0026721987 scopus 로고
    • Characterization and evaluation of a new double lumen central venous catheter
    • Donnelly PK, Morton D, Woffindin C, Hoenich NA. Characterization and evaluation of a new double lumen central venous catheter. Int J Artif Organs 1992;15:331-9.
    • (1992) Int J Artif Organs , vol.15 , pp. 331-339
    • Donnelly, P.K.1    Morton, D.2    Woffindin, C.3    Hoenich, N.A.4
  • 16
    • 0025240760 scopus 로고
    • The use of dual lumen jugular venous catheters as definitive long term access for hemodialysis
    • Blake PG, Huraib S, Wu G, Uldall PR. The use of dual lumen jugular venous catheters as definitive long term access for hemodialysis. Int J Artif Organs 1990;13:26-31.
    • (1990) Int J Artif Organs , vol.13 , pp. 26-31
    • Blake, P.G.1    Huraib, S.2    Wu, G.3    Uldall, P.R.4
  • 17
    • 0025812668 scopus 로고
    • Urokinae infusions restores function of thrombotically-occluded inferior vena cava apheresis catheters refractory to bolus urokinase therapy
    • Haire WD, Lieberman RP, Schmit-Pokorny K, Kessinger A. Urokinae infusions restores function of thrombotically-occluded inferior vena cava apheresis catheters refractory to bolus urokinase therapy. Transfus Sci 1991;12:311-6.
    • (1991) Transfus Sci , vol.12 , pp. 311-316
    • Haire, W.D.1    Lieberman, R.P.2    Schmit-Pokorny, K.3    Kessinger, A.4
  • 19
    • 0019293189 scopus 로고
    • Lagekontrolle großlumiger zentraler Venenkatheter mittels intrakardialer
    • Bambauer R, Jutzler GA. Lagekontrolle großlumiger zentraler Venenkatheter mittels intrakardialer. Elektrokardiographie Intensivmed 1980;17:317.
    • (1980) Elektrokardiographie Intensivmed , vol.17 , pp. 317
    • Bambauer, R.1    Jutzler, G.A.2
  • 20
    • 0026059321 scopus 로고
    • Experimentelle untersuchungen zur cavakatheterisierung mit integrierten EKG-lage-kontrollsystemen
    • Rust M, Kramann B, Warnke U. Experimentelle Untersuchungen zur Cavakatheterisierung mit integrierten EKG-Lage-Kontrollsystemen. Intensiv- U Notfallbehandl 1991;16:117-24.
    • (1991) Intensiv- U Notfallbehandl , vol.16 , pp. 117-124
    • Rust, M.1    Kramann, B.2    Warnke, U.3
  • 21
    • 0020686627 scopus 로고
    • A new silastic subclavian cannula for hemodialysis or plasma exchange
    • Taylor RD, Bone JM. A new silastic subclavian cannula for hemodialysis or plasma exchange. Dial Transplant 1983;12:26.
    • (1983) Dial Transplant , vol.12 , pp. 26
    • Taylor, R.D.1    Bone, J.M.2
  • 23
    • 0001903890 scopus 로고
    • Surface treatment of biomaterials by Ion-Beam Processes
    • Sioshansi P, Tobin EJ. Surface treatment of biomaterials by Ion-Beam Processes. Med Plastics Biomaterials 1995;2:50-9.
    • (1995) Med Plastics Biomaterials , vol.2 , pp. 50-59
    • Sioshansi, P.1    Tobin, E.J.2
  • 24
    • 0017755371 scopus 로고
    • Differenzierung verschiedener kathetermaterialien nach form
    • Dathe G. Differenzierung verschiedener Kathetermaterialien nach Form. Oberfläche Funktion Therapiew 1977;27:5185-6.
    • (1977) Oberfläche Funktion Therapiew , vol.27 , pp. 5185-5186
    • Dathe, G.1
  • 25
    • 0012703688 scopus 로고
    • New surface-treatment technologies for catheters used for extracorporeal detoxification methods
    • Bambauer R, Mestres P, Schiel R, Sioshansi P. New surface-treatment technologies for catheters used for extracorporeal detoxification methods. Dial Transplant 1995;24:228-37.
    • (1995) Dial Transplant , vol.24 , pp. 228-237
    • Bambauer, R.1    Mestres, P.2    Schiel, R.3    Sioshansi, P.4
  • 26
    • 0029092197 scopus 로고
    • Scanning electron microscopic investigation of catheters for blood access
    • Bambauer R, Mestres P, Pirrung KJ, Sioshansi P. Scanning electron microscopic investigation of catheters for blood access. Int J Artif Organs 1995;16:326-31.
    • (1995) Int J Artif Organs , vol.16 , pp. 326-331
    • Bambauer, R.1    Mestres, P.2    Pirrung, K.J.3    Sioshansi, P.4
  • 28
    • 0025339506 scopus 로고
    • In vivo evaluation of antithrombogenicity for ion implanted silicone rubber using indium-tropolone-platelets
    • Suzuki Y, Kusakabe M, Akiba H. In vivo evaluation of antithrombogenicity for ion implanted silicone rubber using indium-tropolone-platelets. Jpn J Artif Organs 1990;19:1092-5.
    • (1990) Jpn J Artif Organs , vol.19 , pp. 1092-1095
    • Suzuki, Y.1    Kusakabe, M.2    Akiba, H.3
  • 29
    • 0028301955 scopus 로고
    • New process for surface treatment of catheters
    • Sioshansi P. New process for surface treatment of catheters. Artif Organs 1994;18:266-71.
    • (1994) Artif Organs , vol.18 , pp. 266-271
    • Sioshansi, P.1
  • 30
    • 0002261588 scopus 로고
    • Ion implantation of cobalt-chronicum prosthetic components to reduce polyethylene wear
    • Sioshansi P. Ion implantation of cobalt-chronicum prosthetic components to reduce polyethylene wear. Orthopedics Today 1991;11:24-5.
    • (1991) Orthopedics Today , vol.11 , pp. 24-25
    • Sioshansi, P.1
  • 32
    • 0023431972 scopus 로고
    • Use of subclavian and internal jugular vein catheterization in hemodialysis and plasmapheresis
    • Bratel J, Pasini J, Thune S et al. Use of subclavian and internal jugular vein catheterization in hemodialysis and plasmapheresis. Licej Vjesn 1987;1094:396-9.
    • (1987) Licej Vjesn , vol.1094 , pp. 396-399
    • Bratel, J.1    Pasini, J.2    Thune, S.3
  • 33
    • 0023193121 scopus 로고
    • Morbidity and mortality of central venous catheter hemodialysis, a review of 10 year's experience
    • Vanholder R, Hoenich N, Ringoir S. Morbidity and mortality of central venous catheter hemodialysis, a review of 10 year's experience. Nephron 1987;47:247-79.
    • (1987) Nephron , vol.47 , pp. 247-279
    • Vanholder, R.1    Hoenich, N.2    Ringoir, S.3
  • 34
    • 0002521284 scopus 로고
    • Pathogenesis, prevention, and management of infections due to intravascular devices used for infusion therapy
    • Bisno SL, Waldvogel FA, eds. Washington DC: American Society for Microbiology
    • Maki DG. Pathogenesis, prevention, and management of infections due to intravascular devices used for infusion therapy. In: Bisno SL, Waldvogel FA, eds. Infections Associated with Indwelling Medical Devices. Washington DC: American Society for Microbiology, 1989;161-77.
    • (1989) Infections Associated with Indwelling Medical Devices , pp. 161-177
    • Maki, D.G.1
  • 35
    • 0023883981 scopus 로고
    • Vascular-access infections in hospitalized patients
    • Hampton AA, Sherertz RJ. Vascular-access infections in hospitalized patients. Surg Clin N Am 1988;68:57-71.
    • (1988) Surg Clin N Am , vol.68 , pp. 57-71
    • Hampton, A.A.1    Sherertz, R.J.2
  • 36
    • 0023683217 scopus 로고
    • An attachable silver-impregnated cuff for prevention of infection with central venous catheters: A prospective randomized multicenter trial
    • Maki DG, Garman JK, Shapiro JM, Rringer M, Helgerson RB. An attachable silver-impregnated cuff for prevention of infection with central venous catheters: A prospective randomized multicenter trial. Am J Medical 1988;85:307-14.
    • (1988) Am J Medical , vol.85 , pp. 307-314
    • Maki, D.G.1    Garman, J.K.2    Shapiro, J.M.3    Rringer, M.4    Helgerson, R.B.5
  • 37
    • 10544250253 scopus 로고    scopus 로고
    • Antiseptic-impregnated non-tunneled central venous catheters: Reducing infection risks and associated costs
    • Civetta J. Antiseptic-impregnated non-tunneled central venous catheters: reducing infection risks and associated costs. Dial Transplant 1996;25:784-99.
    • (1996) Dial Transplant , vol.25 , pp. 784-799
    • Civetta, J.1
  • 38
    • 0031239393 scopus 로고    scopus 로고
    • Silver modification of polyethylene terephthalate textiles for antimicrobial protection
    • Tweden KS, Cameron JD, Razzouk AJ et al. Silver modification of polyethylene terephthalate textiles for antimicrobial protection. ASAIO J 1997;43:M475-81.
    • (1997) ASAIO J , vol.43
    • Tweden, K.S.1    Cameron, J.D.2    Razzouk, A.J.3
  • 39
    • 0026239704 scopus 로고
    • Biofilm formation on peritoneal catheter does not require the presence of infections
    • Schwarz R, Messana J, Holmes C, Williams J. Biofilm formation on peritoneal catheter does not require the presence of infections. ASAIO Trans 1991;37:626-35.
    • (1991) ASAIO Trans , vol.37 , pp. 626-635
    • Schwarz, R.1    Messana, J.2    Holmes, C.3    Williams, J.4
  • 40
    • 0028132746 scopus 로고
    • Biocompatibility of silver coated polyurethane catheters and silver coated Dacron material
    • Oloffs A, Gosse-Siestrup C, Bisson S, Rinke M, Rudolph R. Biocompatibility of silver coated polyurethane catheters and silver coated Dacron material. Biomaterials 1994;15:753-8.
    • (1994) Biomaterials , vol.15 , pp. 753-758
    • Oloffs, A.1    Gosse-Siestrup, C.2    Bisson, S.3    Rinke, M.4    Rudolph, R.5
  • 41
    • 0345404252 scopus 로고    scopus 로고
    • Surface treated large bore catheters with silver based coatings versus untreated catheters for extracorporeal detoxification methods
    • Bambauer R, Mestres P, Schiel R et al. Surface treated large bore catheters with silver based coatings versus untreated catheters for extracorporeal detoxification methods. ASAIO J 1998;44:303-8.
    • (1998) ASAIO J , vol.44 , pp. 303-308
    • Bambauer, R.1    Mestres, P.2    Schiel, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.