메뉴 건너뛰기




Volumn 3, Issue ASIA PACIFIC, 2002, Pages 2129-2133

Multi-agent based control and operation of distribution system with dispersed power sources

Author keywords

Dispersed power sources; Energy Capacitor System; Load following operation; Load leveling; Multi Agent system

Indexed keywords

CAPACITORS; COMPUTER NETWORKS; COMPUTER SIMULATION; DELAY CIRCUITS; ELECTRIC LOADS; MULTI AGENT SYSTEMS; WIND;

EID: 0038306481     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (11)

References (8)
  • 1
    • 0032633854 scopus 로고    scopus 로고
    • Transient analysis of integrated diesel-wind-photovoltaic generation systems
    • F. Bonnano, A. Consoli, A. Raciti, B. Morgana, and U. Nocera, "Transient Analysis of Integrated Diesel-Wind-Photovoltaic Generation Systems", IEEE Trans. on Energy Conversion, Vol. 14, No. 2, 1999, pp.232-238.
    • (1999) IEEE Trans. on Energy Conversion , vol.14 , Issue.2 , pp. 232-238
    • Bonnano, F.1    Consoli, A.2    Raciti, A.3    Morgana, B.4    Nocera, U.5
  • 3
    • 84928780158 scopus 로고
    • A general simulation algorithm for the accurate assessment of isolated diesel-wind turbines systems interaction part I: A general multimachine power system model
    • G. S. Stavrakakis and G. N. Kariniotakis, "A General Simulation Algorithm for the Accurate Assessment of Isolated Diesel-Wind Turbines Systems Interaction Part I: A General Multimachine Power System Model", IEEE Trans. on Energy Conversion, Vol. 10, No. 3, 1995, pp.577-581.
    • (1995) IEEE Trans. on Energy Conversion , vol.10 , Issue.3 , pp. 577-581
    • Stavrakakis, G.S.1    Kariniotakis, G.N.2
  • 4
    • 84943130709 scopus 로고
    • A general simulation algorithm for the accurate assessment of isolated diesel wind turbines systems interaction part II: Implementation of the algorithm and case studies with induction generators
    • G. S. Stavrakakis and G. N. Kariniotakis, "A General Simulation Algorithm for the Accurate Assessment of Isolated Diesel wind Turbines Systems Interaction Part II: Implementation of the Algorithm and Case Studies with Induction Generators", IEEE Trans. on Energy Conversion, Vol. 10, No. 3, 1995, pp.584-590.
    • (1995) IEEE Trans. on Energy Conversion , vol.10 , Issue.3 , pp. 584-590
    • Stavrakakis, G.S.1    Kariniotakis, G.N.2
  • 5
    • 0005354746 scopus 로고
    • A basic study on power storage capacitor systems
    • M. Okamoto, "A Basic Study on Power Storage Capacitor Systems", Trans. IEE of Japan, Vol. 115-B, No.5, 1995.
    • (1995) Trans. IEE of Japan , vol.115 B , Issue.5
    • Okamoto, M.1
  • 6
    • 85010236457 scopus 로고    scopus 로고
    • Novel utility-interactive electrical energy storage system by electrical double layer capacitors and an error tracking mode PWM converter
    • M. Ohshima, M. Shimizu, M. Shimizu, M. Yamagishi, and M. Okamura, "Novel Utility-Interactive Electrical Energy Storage System by Electrical Double Layer Capacitors and an Error Tracking Mode PWM Converter", Trans. IEE of Japan, Vol. 118-D, No. 12, 1998.
    • (1998) Trans. IEE of Japan , vol.118 D , Issue.12
    • Ohshima, M.1    Shimizu, M.2    Shimizu, M.3    Yamagishi, M.4    Okamura, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.