메뉴 건너뛰기




Volumn 50, Issue 5, 2003, Pages 511-513

Blind nasotracheal intubation is facilitated by neutral head position and endotracheal tube cuff inflation in spontaneously breathing patients

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BREATHING PATTERN; CLINICAL OBSERVATION; CONTROLLED STUDY; CUFF; DIAGNOSTIC IMAGING; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; FEMALE; FIBEROPTIC BRONCHOSCOPY; GLOTTIS; HEAD POSITION; HOSPITAL BED; HUMAN; MAJOR CLINICAL STUDY; MALE; MEDICAL EXAMINATION; NECK; PHARYNX; PRIORITY JOURNAL;

EID: 0038303780     PISSN: 0832610X     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03021066     Document Type: Article
Times cited : (23)

References (10)
  • 5
    • 0033769923 scopus 로고    scopus 로고
    • Paramedic success rate for blind nasotracheal intubation is improved with the use of an endotracheal tube with directional tip control
    • O'Connor RE, Megargel RE, Schnyder ME, Madden JF, Bitner M, Ross R. Paramedic success rate for blind nasotracheal intubation is improved with the use of an endotracheal tube with directional tip control. Ann Emerg Med 2000; 36: 328-32.
    • (2000) Ann. Emerg. Med. , vol.36 , pp. 328-332
    • O'Connor, R.E.1    Megargel, R.E.2    Schnyder, M.E.3    Madden, J.F.4    Bitner, M.5    Ross, R.6
  • 6
    • 0029050960 scopus 로고
    • Clinical trial of a new lightwand device (Trachlight) to intubate the trachea
    • Hung OR, Pytka S, Morris I, et al. Clinical trial of a new lightwand device (Trachlight) to intubate the trachea. Anesthesiology 1995; 83: 509-14.
    • (1995) Anesthesiology , vol.83 , pp. 509-514
    • Hung, O.R.1    Pytka, S.2    Morris, I.3
  • 8
    • 0034928140 scopus 로고    scopus 로고
    • Lightwand intubation using the Trachlight™: A brief review of current knowledge
    • Agro F, Hung OR, Cataldo R, Carassiti M, Gherardi S. Lightwand intubation using the Trachlight™: a brief review of current knowledge. Can J Anesth 2001; 48: 592-9.
    • (2001) Can. J. Anesth. , vol.48 , pp. 592-599
    • Agro, F.1    Hung, O.R.2    Cataldo, R.3    Carassiti, M.4    Gherardi, S.5
  • 9
    • 0032931373 scopus 로고    scopus 로고
    • Use of a modified lightwand for nasal intubation
    • (Letter)
    • Iseki K, Murakawa M, Tase C, Otsuki M. Use of a modified lightwand for nasal intubation (Letter). Anesthesiology 1999; 90: 635.
    • (1999) Anesthesiology , vol.90 , pp. 635
    • Iseki, K.1    Murakawa, M.2    Tase, C.3    Otsuki, M.4
  • 10
    • 0036238549 scopus 로고    scopus 로고
    • Effective nasotracheal intubation using a modified transillumination technique
    • Favaro R, Tordiglione P, Di Lascio F, et al. Effective nasotracheal intubation using a modified transillumination technique. Can J Anesth 2002; 49: 91-5.
    • (2002) Can. J. Anesth. , vol.49 , pp. 91-95
    • Favaro, R.1    Tordiglione, P.2    Di Lascio, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.