메뉴 건너뛰기




Volumn 6, Issue 2, 2003, Pages 145-148

Fundamental study of an electric power transmission system for implanted medical devices using magnetic and ultrasonic energy

Author keywords

Magnetic field; Magnetostriction device; Noninvasive transmission; Piezo vibrator; Ultrasonic

Indexed keywords

ARTICLE; ARTIFICIAL HEART PACEMAKER; DEVICE; FREQUENCY ANALYSIS; IMPLANTATION; MAGNETIC FIELD; MAGNETISM; MEDICAL INSTRUMENTATION; PIEZOELECTRICITY; POWER SUPPLY; PRIORITY JOURNAL; ULTRASOUND;

EID: 0038270075     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-003-0209-9     Document Type: Article
Times cited : (17)

References (6)
  • 1
    • 0024739663 scopus 로고
    • High-output transmitting coil with structure utilizing amorphous fiber for implanted artificial heart
    • Matsuki H, Nadehara K, Watanabe T, Murakami K, Yamamoto T. High-output transmitting coil with structure utilizing amorphous fiber for implanted artificial heart. IEEE Trans Magn 1989;25:3812-3814
    • (1989) IEEE Trans Magn , vol.25 , pp. 3812-3814
    • Matsuki, H.1    Nadehara, K.2    Watanabe, T.3    Murakami, K.4    Yamamoto, T.5
  • 2
    • 0009767077 scopus 로고    scopus 로고
    • Feasibility of a remote monitoring system for patients with an implantable left ventricular assist device using Personal Handy-Phone System telecommunication technology
    • Okamoto E, Iwazawa E, Suzuki S, Fukuoka S, Mitamura Y. Feasibility of a remote monitoring system for patients with an implantable left ventricular assist device using Personal Handy-Phone System telecommunication technology. J Artif Organs 2001;4:172-179
    • (2001) J Artif Organs , vol.4 , pp. 172-179
    • Okamoto, E.1    Iwazawa, E.2    Suzuki, S.3    Fukuoka, S.4    Mitamura, Y.5
  • 3
    • 0035328116 scopus 로고    scopus 로고
    • Power and information transmission to implanted medical device using ultrasonic
    • Kawanabe H, Katane T, Saotome H, Saito O, Kobayashi K. Power and information transmission to implanted medical device using ultrasonic. Jpn J Appl Phys 2001;40:3865-3866
    • (2001) Jpn J Appl Phys , vol.40 , pp. 3865-3866
    • Kawanabe, H.1    Katane, T.2    Saotome, H.3    Saito, O.4    Kobayashi, K.5
  • 4
    • 0036578142 scopus 로고    scopus 로고
    • Power and interactive information transmission to implanted medical device using ultrasonic
    • Suzuki S, Kimura S, Katane T, Saotome H, Saito O, Kobayashi K. Power and interactive information transmission to implanted medical device using ultrasonic. Jpn J Appl Phys 2002;41:3600-3603
    • (2002) Jpn J Appl Phys , vol.41 , pp. 3600-3603
    • Suzuki, S.1    Kimura, S.2    Katane, T.3    Saotome, H.4    Saito, O.5    Kobayashi, K.6
  • 5
    • 0033183886 scopus 로고    scopus 로고
    • A proposal for electric power generating systems for implanted medical devices
    • Suzuki S, Katane T, Saotome H, Salto O. A proposal for electric power generating systems for implanted medical devices. IEEE Trans Magn 1999;35:3586-3588
    • (1999) IEEE Trans Magn , vol.35 , pp. 3586-3588
    • Suzuki, S.1    Katane, T.2    Saotome, H.3    Salto, O.4
  • 6
    • 0036761698 scopus 로고    scopus 로고
    • Electric power generating system using magnetic coupling for medical electronic devices
    • Suzuki S, Katane T, Saotome H, Saito O. Electric power generating system using magnetic coupling for medical electronic devices. IEEE Trans Magn 2002;38:3006-3008
    • (2002) IEEE Trans Magn , vol.38 , pp. 3006-3008
    • Suzuki, S.1    Katane, T.2    Saotome, H.3    Saito, O.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.