Volumn 26, Issue 7 I, 2003, Pages 1494-1497

Induction ovens and electromagnetic interference: What is the risk for patients with implanted pacemakers?

Author keywords

Electromagnetic interference; Induction oven; Pacemaker; Pacing

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CARDIOVASCULAR RISK; CLINICAL ARTICLE; CONTROLLED STUDY; ELECTROMAGNETIC FIELD; ENERGY; EQUIPMENT; FEMALE; HEART PACING; HEART RATE; HEART RHYTHM; HOUSEHOLD; HUMAN; INCIDENCE; MALE; MEASUREMENT; MONITORING; PACEMAKER FAILURE; PARAMETER; PATIENT; SITTING;

EID: 0038270016     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.2003.t01-1-00216.x     Document Type: Article
Times cited : (22)

References (13)
  • 1
    • 0030765826 scopus 로고    scopus 로고
    • Influence of digital and analogue cellular telephones on implanted pacemakers
    • Altamura G, Toscano S, Gentilucci G, et al. Influence of digital and analogue cellular telephones on implanted pacemakers. Eur Heart J 1997; 18:1632-1641.
    • (1997) Eur Heart J , vol.18 , pp. 1632-1641
    • Altamura, G.1    Toscano, S.2    Gentilucci, G.3
  • 2
    • 0035186645 scopus 로고    scopus 로고
    • Pacemakers and store security devices
    • Harthorne JW. Pacemakers and store security devices. Cardiol Rev 2001; 9:10-17.
    • (2001) Cardiol Rev , vol.9 , pp. 10-17
    • Harthorne, J.W.1
  • 3
    • 0029837925 scopus 로고    scopus 로고
    • Electromagnetic interference of pacemakers by mobile phones
    • Irnich W, Batz L, Muller R, et al. Electromagnetic interference of pacemakers by mobile phones. PACE 1996; 19:1431-1446.
    • (1996) PACE , vol.19 , pp. 1431-1446
    • Irnich, W.1    Batz, L.2    Muller, R.3
  • 4
    • 0029930964 scopus 로고    scopus 로고
    • Intermittent pacemaker dysfunction caused by digital mobile telephones
    • Naegeli B, Osswald S, Deola M, et al. Intermittent pacemaker dysfunction caused by digital mobile telephones. J Am Coll Cardiol 1996; 27:1471-1477.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 1471-1477
    • Naegeli, B.1    Osswald, S.2    Deola, M.3
  • 5
    • 0029837340 scopus 로고    scopus 로고
    • Is there a risk for interaction between mobile phones and single lead VDD pacemakers?
    • Nowak B, Rosocha S, Zellerhoff C, et al. Is there a risk for interaction between mobile phones and single lead VDD pacemakers? PACE 1996; 19:1447-1450.
    • (1996) PACE , vol.19 , pp. 1447-1450
    • Nowak, B.1    Rosocha, S.2    Zellerhoff, C.3
  • 6
    • 0002561310 scopus 로고    scopus 로고
    • Electromagnetic interference in current implantable devices
    • PE Vardas (ed.). Dordrecht, the Netherlands, Kluwer Academic Publishers
    • Irnich W. Electromagnetic interference in current implantable devices. In PE Vardas (ed.): Cardiac Arrhythmias, Pacing & Electrophysiology. Dordrecht, the Netherlands, Kluwer Academic Publishers, 1998, pp. 427-436.
    • (1998) Cardiac Arrhythmias, Pacing & Electrophysiology , pp. 427-436
    • Irnich, W.1
  • 7
    • 0031464832 scopus 로고    scopus 로고
    • Interference with cardiac pacemaker by electric induction cooktops
    • Preumont N, Ahadi N, Rahnama M, et al. Interference with cardiac pacemaker by electric induction cooktops. Acta Cardiol 1997; 5:446.
    • (1997) Acta Cardiol , vol.5 , pp. 446
    • Preumont, N.1    Ahadi, N.2    Rahnama, M.3
  • 8
    • 0034942717 scopus 로고    scopus 로고
    • Pacing in magnetic resonance imaging environment: Clinical and technical considerations on compatibility
    • Duru F, Luechinger R, Scheidegger MB, et al. Pacing in magnetic resonance imaging environment: Clinical and technical considerations on compatibility. Eur Heart J 2001; 22:113-124.
    • (2001) Eur Heart J , vol.22 , pp. 113-124
    • Duru, F.1    Luechinger, R.2    Scheidegger, M.B.3
  • 9
    • 0023138250 scopus 로고
    • Current facts on pacemaker electromagnetic interference and their application to clinical care
    • Sager DP. Current facts on pacemaker electromagnetic interference and their application to clinical care. Heart Lung 1987; 16:211-221.
    • (1987) Heart Lung , vol.16 , pp. 211-221
    • Sager, D.P.1
  • 10
    • 0030925632 scopus 로고    scopus 로고
    • Interference with cardiac pacemakers by cellular telephones
    • Hayes DL, Wang PJ, Reynolds DW, et al. Interference with cardiac pacemakers by cellular telephones. N Engl J Med 1997; 336:1473-1479.
    • (1997) N Engl J Med , vol.336 , pp. 1473-1479
    • Hayes, D.L.1    Wang, P.J.2    Reynolds, D.W.3
  • 11
    • 0031008510 scopus 로고    scopus 로고
    • Cardiac pacemakers and cellular telephones
    • Roelke M, Bernstein AD. Cardiac pacemakers and cellular telephones. N Engl J Med 1997; 336:1518-1519.
    • (1997) N Engl J Med , vol.336 , pp. 1518-1519
    • Roelke, M.1    Bernstein, A.D.2
  • 12
    • 0038219104 scopus 로고
    • EMF in Your Environment: Magnetic Field Measurements of Everyday Electrical Devices
    • EMF in Your Environment: Magnetic Field Measurements of Everyday Electrical Devices, U.S. Environmental Protection Agency (EPA) Booklet, 1992. pp. 32.
    • (1992) U.S. Environmental Protection Agency (EPA) Booklet , pp. 32
  • 13
    • 0034937673 scopus 로고    scopus 로고
    • A life after pacemaker implantation: Management of common problems and environmental interactions
    • Shah PM, Ellenbogen K. A life after pacemaker implantation: Management of common problems and environmental interactions. Cardiol Rev 2001; 9:193-201.
    • (2001) Cardiol Rev , vol.9 , pp. 193-201
    • Shah, P.M.1    Ellenbogen, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.