-
1
-
-
0027504581
-
Separate acquisition rest thallium-201/stess technetium-99m sestamibi dual-isotope myocardial perfusion SPECT: A clinical validation study
-
Berman DS, Kiat H, Friedman JD, et al. Separate acquisition rest thallium-201/stess technetium-99m sestamibi dual-isotope myocardial perfusion SPECT: a clinical validation study. J Am Coll Cardiol 1993; 22:1455-1464.
-
(1993)
J Am Coll Cardiol
, vol.22
, pp. 1455-1464
-
-
Berman, D.S.1
Kiat, H.2
Friedman, J.D.3
-
2
-
-
0028206634
-
Dual-isotope myocardial imaging: Feasibility, advantages and limitations. Preliminary report on 231 consecutive patients
-
Weinmann P, Foult JM, Le Guludec D, et al. Dual-isotope myocardial imaging: feasibility, advantages and limitations. Preliminary report on 231 consecutive patients. Eur J Nucl Med 1994; 21:212-215.
-
(1994)
Eur J Nucl Med
, vol.21
, pp. 212-215
-
-
Weinmann, P.1
Foult, J.M.2
Le Guludec, D.3
-
3
-
-
0028100009
-
Pharmacologic stress dual-isotope myocardial perfusion single-photon emission computed tomography
-
Matzer L, Kiat H, Wang FP, Van Train K, Germano G, Friedman J, Berman DS. Pharmacologic stress dual-isotope myocardial perfusion single-photon emission computed tomography. Am Heart J 1994; 128:1067-1076.
-
(1994)
Am Heart J
, vol.128
, pp. 1067-1076
-
-
Matzer, L.1
Kiat, H.2
Wang, F.P.3
Van Train, K.4
Germano, G.5
Friedman, J.6
Berman, D.S.7
-
4
-
-
0031881794
-
Photon energy recovery: A method to improve the effective energy resolution of gamma cameras
-
Hannequin P, Mas J. Photon energy recovery: a method to improve the effective energy resolution of gamma cameras. J Nucl Med 1998; 39:555-562.
-
(1998)
J Nucl Med
, vol.39
, pp. 555-562
-
-
Hannequin, P.1
Mas, J.2
-
6
-
-
0035039019
-
Preliminary clinical results of photon energy recovery in simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT
-
Hannequin P, Weinmann P, Mas J, Vinot S. Preliminary clinical results of photon energy recovery in simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT. J Nucl Cardiol 2001; 8:144-151.
-
(2001)
J Nucl Cardiol
, vol.8
, pp. 144-151
-
-
Hannequin, P.1
Weinmann, P.2
Mas, J.3
Vinot, S.4
-
7
-
-
0028807603
-
Effects of scatter correction on the measurement of infarct size from SPECT cardiac phantom studies
-
O'Connor MK, Caiati C, Christian TF, Gibbons RJ. Effects of scatter correction on the measurement of infarct size from SPECT cardiac phantom studies. J Nucl Med 1995; 36:2080-2086.
-
(1995)
J Nucl Med
, vol.36
, pp. 2080-2086
-
-
O'Connor, M.K.1
Caiati, C.2
Christian, T.F.3
Gibbons, R.J.4
-
8
-
-
0028218858
-
Comparative feasibility of separate or simultaneous rest thallium-201/stress technetium-99m-sestamibi dual-isotope myocardial perfusion SPECT
-
Kiat H, Germano G, Friedman J, et al. Comparative feasibility of separate or simultaneous rest thallium-201/stress technetium-99m-sestamibi dual-isotope myocardial perfusion SPECT. J Nucl Med 1994; 35:542-548.
-
(1994)
J Nucl Med
, vol.35
, pp. 542-548
-
-
Kiat, H.1
Germano, G.2
Friedman, J.3
-
9
-
-
0027991095
-
Comparison of reinjection thallium-201 and resting technetium-99m sestamibi tomographic images for the quantification of infarct size after acute myocardial infarction
-
Christian TF, O'Connor MK, Hopfenspirger MR, Gibbons RJ. Comparison of reinjection thallium-201 and resting technetium-99m sestamibi tomographic images for the quantification of infarct size after acute myocardial infarction. J Nucl Cardiol 1994; 1:17-28.
-
(1994)
J Nucl Cardiol
, vol.1
, pp. 17-28
-
-
Christian, T.F.1
O'Connor, M.K.2
Hopfenspirger, M.R.3
Gibbons, R.J.4
-
10
-
-
0028146615
-
A method of simultaneous dual radionuclide cardiac imaging with technetium-99m and thallium-201: Analysis of interradio-nuclide crossover and validation in phantoms
-
Weinstein H, King M, Reinhardt C, Mc Sherry B, Leppo JA. A method of simultaneous dual radionuclide cardiac imaging with technetium-99m and thallium-201: analysis of interradio-nuclide crossover and validation in phantoms. J Nucl Cardiol 1994; 1:39-51.
-
(1994)
J Nucl Cardiol
, vol.1
, pp. 39-51
-
-
Weinstein, H.1
King, M.2
Reinhardt, C.3
Mc Sherry, B.4
Leppo, J.A.5
-
11
-
-
0037517906
-
201Tl myocardial SPECT: Quantitative differences between the images recorded in the 70 keV and the 167 keV windows
-
201Tl myocardial SPECT: quantitative differences between the images recorded in the 70 keV and the 167 keV windows [abstract]. Eur J Nucl Med 2000; 27:896.
-
(2000)
Eur J Nucl Med
, vol.27
, pp. 896
-
-
Hannequin, P.1
Weinmann, P.2
Mas, J.3
-
12
-
-
85047675728
-
Effect of hyperaemia on thallium-201 redistribution in normal canine myocardium
-
Leppo JA, Okada RD, Strauss HW, Pohost GM. Effect of hyperaemia on thallium-201 redistribution in normal canine myocardium. Cardiovasc Res 1985; 19:679-685.
-
(1985)
Cardiovasc Res
, vol.19
, pp. 679-685
-
-
Leppo, J.A.1
Okada, R.D.2
Strauss, H.W.3
Pohost, G.M.4
-
14
-
-
0026541776
-
Myocardial "stunning" in man
-
Bolli R. Myocardial "stunning" in man. Circulation 1992; 86:1671-1691.
-
(1992)
Circulation
, vol.86
, pp. 1671-1691
-
-
Bolli, R.1
|