메뉴 건너뛰기




Volumn 15, Issue SUPPL. A, 2003, Pages

Durable clinical benefit following Sr90 beta irradiation therapy for in-stent restenosis in high-volume community practice

Author keywords

[No Author keywords available]

Indexed keywords

ANTITHROMBOCYTIC AGENT; IRIDIUM 192; PHOSPHORUS 32; STRONTIUM 90; STRONTIUM;

EID: 0038175269     PISSN: 10423931     EISSN: 15572501     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (29)
  • 1
    • 0028123099 scopus 로고
    • A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease
    • Serruys PW, de Jaegere P, Kiemeneeij F, et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med 1994;331:489-495.
    • (1994) N Engl J Med , vol.331 , pp. 489-495
    • Serruys, P.W.1    De Jaegere, P.2    Kiemeneeij, F.3
  • 2
    • 0027934377 scopus 로고
    • A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease
    • Fischman DL, Leon MB, Baim DS, et al. A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med 1994;331:496-501.
    • (1994) N Engl J Med , vol.331 , pp. 496-501
    • Fischman, D.L.1    Leon, M.B.2    Baim, D.S.3
  • 3
    • 0032209736 scopus 로고    scopus 로고
    • ACC expert document on coronary artery stents. Document of the American College of Cardiology
    • Holmes DR, Hirshfeld J, Faxon D, et al. ACC expert document on coronary artery stents. Document of the American College of Cardiohgy. J Am Coll Cardiol 1998;32:1471-1482.
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1471-1482
    • Holmes, D.R.1    Hirshfeld, J.2    Faxon, D.3
  • 4
    • 0033564883 scopus 로고    scopus 로고
    • Influence of lesion length on restenosis after coronary stent placement
    • Kastrati A, Elezi S, Dirschinger J, et al. Influence of lesion length on restenosis after coronary stent placement. Am J Cardiol 1999;83:1617-1622.
    • (1999) Am J Cardiol , vol.83 , pp. 1617-1622
    • Kastrati, A.1    Elezi, S.2    Dirschinger, J.3
  • 5
    • 0031909566 scopus 로고    scopus 로고
    • Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents
    • Hoffmann R, Mintz GS, Mehran R, et al. Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents. J Am Coll Cardiol 1998;31:43-49.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 43-49
    • Hoffmann, R.1    Mintz, G.S.2    Mehran, R.3
  • 6
    • 0032533254 scopus 로고    scopus 로고
    • Angiographic and clinical outcome following coronary stenting of small vessels: A comparison with coronary stenting of large vessels
    • Akiyama T, Moussa I, Reimers B, et al. Angiographic and clinical outcome following coronary stenting of small vessels: a comparison with coronary stenting of large vessels. J Am Coll Cardiol 1998;32:1610-1618.
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1610-1618
    • Akiyama, T.1    Moussa, I.2    Reimers, B.3
  • 7
    • 0033913882 scopus 로고    scopus 로고
    • Usefulness of stent length in predicting in-stent restenosis (The Multi-Link Stent Trials)
    • Kereiakes D, Linnemeier TJ, Baim DS, et al. Usefulness of stent length in predicting in-stent restenosis (The Multi-Link Stent Trials). Am J Cardiol 2000;86:336-341.
    • (2000) Am J Cardiol , vol.86 , pp. 336-341
    • Kereiakes, D.1    Linnemeier, T.J.2    Baim, D.S.3
  • 8
    • 0037123131 scopus 로고    scopus 로고
    • The impact of lesion length and reference vessel diameter on angiographic restenosis and target vessel revascularization in treating in-stent restenosis with radiation
    • Ajani AE, Waksman R, Cha DH, et al. The impact of lesion length and reference vessel diameter on angiographic restenosis and target vessel revascularization in treating in-stent restenosis with radiation. J Am Coll Cardiol 2002;39:1290-1296.
    • (2002) J Am Coll Cardiol , vol.39 , pp. 1290-1296
    • Ajani, A.E.1    Waksman, R.2    Cha, D.H.3
  • 9
    • 0031005933 scopus 로고    scopus 로고
    • Catheter-based radiotherapy to inhibit restenosis after coronary stenting
    • Teirstein PS, Massullo V, Jani S, et al. Catheter-based radiotherapy to inhibit restenosis after coronary stenting. N Engl J Med 1997;336:1697-1703.
    • (1997) N Engl J Med , vol.336 , pp. 1697-1703
    • Teirstein, P.S.1    Massullo, V.2    Jani, S.3
  • 10
    • 17544400054 scopus 로고    scopus 로고
    • Intracoronary beta-radiation therapy inhibits recurrence of in-stent restenosis
    • Waksman R, Bhargava B, White L, et al. Intracoronary beta-radiation therapy inhibits recurrence of in-stent restenosis. Circulation 2000;101:1895-1898.
    • (2000) Circulation , vol.101 , pp. 1895-1898
    • Waksman, R.1    Bhargava, B.2    White, L.3
  • 11
    • 17044453495 scopus 로고    scopus 로고
    • Inhibition of restenosis with beta-emitting radiotherapy: Report of the Proliferation Reduction with Vascular Energy Trial (PREVENT)
    • Raizner AE, Oesterle SN, Waksman R, et al. Inhibition of restenosis with beta-emitting radiotherapy: Report of the Proliferation Reduction with Vascular Energy Trial (PREVENT). Circulation 2000;102:951-958.
    • (2000) Circulation , vol.102 , pp. 951-958
    • Raizner, A.E.1    Oesterle, S.N.2    Waksman, R.3
  • 12
    • 0035945670 scopus 로고    scopus 로고
    • Endoluminal beta-radiation therapy for the prevention of coronary restenosis after balloon angioplasty: The Dose-Finding study group
    • Verin V, Popowski Y, de Bruyne B, et al. Endoluminal beta-radiation therapy for the prevention of coronary restenosis after balloon angioplasty: The Dose-Finding study group. N Engl J Med 2001;344:243-249.
    • (2001) N Engl J Med , vol.344 , pp. 243-249
    • Verin, V.1    Popowski, Y.2    De Bruyne, B.3
  • 13
    • 0037116881 scopus 로고    scopus 로고
    • Use of localized intracoronary beta radiation in treatment of instent restenosis: The INHIBIT randomized controlled trial
    • Waksman R, Raizner AE, Yeung AC, et al. Use of localized intracoronary beta radiation in treatment of instent restenosis: The INHIBIT randomized controlled trial. Lancet 2002;359:551-557.
    • (2002) Lancet , vol.359 , pp. 551-557
    • Waksman, R.1    Raizner, A.E.2    Yeung, A.C.3
  • 14
    • 0037199427 scopus 로고    scopus 로고
    • 90 therapy for restenosis prevention after balloon angioplasty
    • 90 therapy for restenosis prevention after balloon angioplasty. Circulation 2002;106:539-543.
    • (2002) Circulation , vol.106 , pp. 539-543
    • Meerkin, D.1    Joyal, M.2    Tardif, J.C.3
  • 15
    • 0028358762 scopus 로고
    • The relative importance of arterial remodeling compared with intimal hyperplasia in lumen narrowing after balloon angioplasty
    • Post MJ, Borst C, Kuntz RE. The relative importance of arterial remodeling compared with intimal hyperplasia in lumen narrowing after balloon angioplasty. Circulation 1994;89:2816-2821.
    • (1994) Circulation , vol.89 , pp. 2816-2821
    • Post, M.J.1    Borst, C.2    Kuntz, R.E.3
  • 16
    • 0030186375 scopus 로고    scopus 로고
    • Arterial remodeling after coronary angioplasty: A serial intravascular ultrasound study
    • Mintz GS, Popma JJ, Pichard AD, et al. Arterial remodeling after coronary angioplasty: A serial intravascular ultrasound study. Circulation 1996;94:35-43.
    • (1996) Circulation , vol.94 , pp. 35-43
    • Mintz, G.S.1    Popma, J.J.2    Pichard, A.D.3
  • 17
    • 0029837889 scopus 로고    scopus 로고
    • Patterns and mechanisms of in-stent restenosis. A serial intravascular ultrasound study
    • Hoffman R, Mintz GS, Dussaillant GR, et al. Patterns and mechanisms of in-stent restenosis. A serial intravascular ultrasound study. Circulation 1996;94:1247-1254.
    • (1996) Circulation , vol.94 , pp. 1247-1254
    • Hoffman, R.1    Mintz, G.S.2    Dussaillant, G.R.3
  • 18
    • 0032881575 scopus 로고    scopus 로고
    • Stented segment length as an independent predictor of restenosis
    • Kobayashi Y, DeGregorio J, Kobayashi N, et al. Stented segment length as an independent predictor of restenosis. J Am Coll Cardiol 1999;34:651-659.
    • (1999) J Am Coll Cardiol , vol.34 , pp. 651-659
    • Kobayashi, Y.1    DeGregorio, J.2    Kobayashi, N.3
  • 19
    • 0028959726 scopus 로고
    • Endovascular low-dose irradiation inhibits neointima formation after coronary artery balloon injury in swine. A possible role for radiation therapy in restenosis prevention
    • Waksman R, Robinson KA, Crocker IR, et al. Endovascular low-dose irradiation inhibits neointima formation after coronary artery balloon injury in swine. A possible role for radiation therapy in restenosis prevention. Circulation 1995;91:1533-1539.
    • (1995) Circulation , vol.91 , pp. 1533-1539
    • Waksman, R.1    Robinson, K.A.2    Crocker, I.R.3
  • 20
    • 0034142223 scopus 로고    scopus 로고
    • Three-year clinical and angiographic follow-up after intracoronary radiation: Results of a randomized clinical trial
    • Teirstein PS, Massullo V, Jani S, et al. Three-year clinical and angiographic follow-up after intracoronary radiation: Results of a randomized clinical trial. Circulation 2000;101:360-365.
    • (2000) Circulation , vol.101 , pp. 360-365
    • Teirstein, P.S.1    Massullo, V.2    Jani, S.3
  • 21
    • 0033517846 scopus 로고    scopus 로고
    • Angiographic patterns of in-stent restenosis: Classification and implications for long-term outcome
    • Mehran R, Dangas G, Abizaid AS, et al. Angiographic patterns of in-stent restenosis: Classification and implications for long-term outcome. Circulation 1999;100:1872-1878.
    • (1999) Circulation , vol.100 , pp. 1872-1878
    • Mehran, R.1    Dangas, G.2    Abizaid, A.S.3
  • 22
    • 0033528663 scopus 로고    scopus 로고
    • Effects of intracoronary β-radiation therapy after coronary angioplasty: An intravascular ultrasound study
    • Meerkin D, Tardif JC, Crocker IR, et al. Effects of intracoronary β-radiation therapy after coronary angioplasty: An intravascular ultrasound study. Circulation 1999;99:1660-1665.
    • (1999) Circulation , vol.99 , pp. 1660-1665
    • Meerkin, D.1    Tardif, J.C.2    Crocker, I.R.3
  • 23
    • 0034133699 scopus 로고    scopus 로고
    • Vascular brachytherapy: Update on clinical trials
    • Waksman R. Vascular brachytherapy: Update on clinical trials. J Invas Cardiol 2000;12(Suppl A):18A-28A.
    • (2000) J Invas Cardiol , vol.12 , Issue.SUPPL. A
    • Waksman, R.1
  • 24
    • 0034646182 scopus 로고    scopus 로고
    • The effect of endovascular irradiation on platelet recruitment at sites of balloon angioplasty in pig coronary arteries
    • Salame MY, Verheye S, Mulkey SP, et al. The effect of endovascular irradiation on platelet recruitment at sites of balloon angioplasty in pig coronary arteries. Circulation 2000;101:1087-1090.
    • (2000) Circulation , vol.101 , pp. 1087-1090
    • Salame, M.Y.1    Verheye, S.2    Mulkey, S.P.3
  • 26
    • 0036198298 scopus 로고    scopus 로고
    • Combination antiplatelet therapy following brachytherapy with restenting: "It ain't over til the fat lady sings"
    • Kereiakes DJ, Choo JK, Young JJ, et al. Combination antiplatelet therapy following brachytherapy with restenting: "It ain't over til the fat lady sings". J Invas Cardiol 2002;14:115-117.
    • (2002) J Invas Cardiol , vol.14 , pp. 115-117
    • Kereiakes, D.J.1    Choo, J.K.2    Young, J.J.3
  • 27
    • 0037072461 scopus 로고    scopus 로고
    • Twelve versus six months of clopidogrel to reduce major cardiac events in patients undergoing β-radiation therapy for in-stent restenosis. Washington Radiation for In-Stent restenosis Trial (WRIST) 12 versus WRIST PLUS
    • Waksman R, Ajani AE, Pinnow E, et al. Twelve versus six months of clopidogrel to reduce major cardiac events in patients undergoing β-radiation therapy for in-stent restenosis. Washington Radiation for In-Stent restenosis Trial (WRIST) 12 versus WRIST PLUS. Circulation 2002;106:776-778.
    • (2002) Circulation , vol.106 , pp. 776-778
    • Waksman, R.1    Ajani, A.E.2    Pinnow, E.3
  • 28
    • 0035899289 scopus 로고    scopus 로고
    • Effects of clopidogrel in addition to aspirin in patients with acute coronary syndromes without ST-segment elevation
    • The Clopidogrel in Unstable angina to prevent Recurrent Events (CURE) trial investigators. Effects of clopidogrel in addition to aspirin in patients with acute coronary syndromes without ST-segment elevation. N Engl J Med 2001;345:494-502.
    • (2001) N Engl J Med , vol.345 , pp. 494-502
  • 29
    • 0035908781 scopus 로고    scopus 로고
    • Effects of pretreatment with clopidogrel and aspirin followed by long-term therapy in patients undergoing percutaneous coronary intervention: The PCI-CURE study
    • Mehta SR, Yusuf S, Peters R, et al. Effects of pretreatment with clopidogrel and aspirin followed by long-term therapy in patients undergoing percutaneous coronary intervention: The PCI-CURE study. Lancet 2001;358:527-533.
    • (2001) Lancet , vol.358 , pp. 527-533
    • Mehta, S.R.1    Yusuf, S.2    Peters, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.