메뉴 건너뛰기




Volumn 1, Issue , 2003, Pages 252-257

A low-cost DSP-based equipment for the detection of transients in power systems

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; DIGITAL SIGNAL PROCESSING; FREQUENCY DOMAIN ANALYSIS; HIGH PASS FILTERS; REAL TIME SYSTEMS; TRANSIENTS; DATA ACQUISITION; DIGITAL FILTERS; LOW PASS FILTERS; MONITORING; POWER QUALITY; UNITS OF MEASUREMENT;

EID: 0038169990     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (7)

References (11)
  • 1
    • 0030126570 scopus 로고    scopus 로고
    • Power quality assessment via wavelet transform analysis
    • S. Santoso, E.J. Powers, P. Hofmann, "Power quality assessment via wavelet transform analysis", IEEE Trans.Power Delivery, vol. 11, no. 2, 1996, pp. 924-930.
    • (1996) IEEE Trans.Power Delivery , vol.11 , Issue.2 , pp. 924-930
    • Santoso, S.1    Powers, E.J.2    Hofmann, P.3
  • 2
    • 0028749580 scopus 로고
    • An analog method for detecting superimposed power line voltage disturbances
    • H. W. Furst, M. Pigl, J. Baier, "An analog method for detecting superimposed power line voltage disturbances", IEEE Trans. on Instr. Meas., vol. 44, no. 6, 1994, pp. 889-893.
    • (1994) IEEE Trans. on Instr. Meas. , vol.44 , Issue.6 , pp. 889-893
    • Furst, H.W.1    Pigl, M.2    Baier, J.3
  • 3
    • 0038359180 scopus 로고    scopus 로고
    • Solutions for improving the performance of data acquisition systems
    • Osaka (Japan), June
    • L. Angrisani, P. Daponte, S. Sangiovanni, "Solutions for improving the performance of data acquisition systems", Proc. XV IMEKO World Congress, Osaka (Japan), June 1999, vol. IV, pp. 55-62.
    • (1999) Proc. XV IMEKO World Congress , vol.4 , pp. 55-62
    • Angrisani, L.1    Daponte, P.2    Sangiovanni, S.3
  • 4
    • 0025384384 scopus 로고
    • A System for capturing and presenting short duration voltage surges on ac power lines
    • A. McEachern, "A System for capturing and presenting short duration voltage surges on ac power lines", IEEE Trans. on Instr. Meas., vol. 39, no.1, 1989, pp. 38-41.
    • (1989) IEEE Trans. on Instr. Meas. , vol.39 , Issue.1 , pp. 38-41
    • McEachern, A.1
  • 5
    • 0036052458 scopus 로고    scopus 로고
    • Metrological characterization of a measurement station for power quality evaluation
    • Anchorage (USA), May
    • G. Bucci, F. Fiorucci, C. Landi, "Metrological characterization of a measurement station for power quality evaluation", Proc. IEEE IMTC/02, Anchorage (USA), May 2002, vol. 1, pp. 619-624.
    • (2002) Proc. IEEE IMTC/02 , vol.1 , pp. 619-624
    • Bucci, G.1    Fiorucci, F.2    Landi, C.3
  • 8
    • 0035152204 scopus 로고    scopus 로고
    • Feasibility of fractal-based methods for visualization of power systems disturbances
    • January
    • S.J. Huang, C.T. Hsieh, "Feasibility of fractal-based methods for visualization of power systems disturbances", Inter. Power Energy Sys. January 2001, pp. 31-36.
    • (2001) Inter. Power Energy Sys. , pp. 31-36
    • Huang, S.J.1    Hsieh, C.T.2
  • 9
    • 0036949027 scopus 로고    scopus 로고
    • Simple ideas for light but robust signal processing of electromechanical systems
    • Sevilla (Spain), November
    • F. Filippetti, M. Artioli, "Simple ideas for light but robust signal processing of electromechanical systems", Proc. IEEE IECON'02, Sevilla (Spain), November 2002, vol. 4, pp. 3366-3371.
    • (2002) Proc. IEEE IECON'02 , vol.4 , pp. 3366-3371
    • Filippetti, F.1    Artioli, M.2
  • 10
    • 0038359181 scopus 로고    scopus 로고
    • http://grouper.ieee.org./goups/1159/


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.