메뉴 건너뛰기




Volumn 31, Issue 3, 2003, Pages 282-285

Feasibility, accuracy and optimal location for oesophageal core temperature measurements using the ProSeal laryngeal mask airway drain tube

Author keywords

Equipment: ProSeal laryngeal mask airway; Monitoring: oesophageal temperature

Indexed keywords

ADULT; AGED; ANESTHESIA INDUCTION; ARTICLE; ARTIFICIAL VENTILATION; BODY TEMPERATURE; CLINICAL ARTICLE; CONTROLLED STUDY; CORE TEMPERATURE; ESOPHAGUS; FEASIBILITY STUDY; FEMALE; HUMAN; INTERMETHOD COMPARISON; LARYNGEAL MASK; MALE; MIDDLE EAR; NASOPHARYNX; REFERENCE VALUE; TEMPERATURE MEASUREMENT; THERMISTOR; THERMOGRAPHY;

EID: 0038150772     PISSN: 0310057X     EISSN: None     Source Type: Journal    
DOI: 10.1177/0310057x0303100307     Document Type: Article
Times cited : (8)

References (15)
  • 1
    • 0034110143 scopus 로고    scopus 로고
    • The LMA "ProSeal" - A laryngeal mask with an oesophageal vent
    • Brain AIJ, Verghese C, Strube PJ. The LMA "ProSeal" - a laryngeal mask with an oesophageal vent. Br J Anaesth 2000; 84:650-654.
    • (2000) Br. J. Anaesth. , vol.84 , pp. 650-654
    • Brain, A.I.J.1    Verghese, C.2    Strube, P.J.3
  • 2
    • 0033945680 scopus 로고    scopus 로고
    • The ProSeal laryngeal mask airway. A randomized, crossover study with the standard laryngeal mask airway in paralyzed, anesthetized patients
    • Brimacombe J, Keller C. The ProSeal laryngeal mask airway. A randomized, crossover study with the standard laryngeal mask airway in paralyzed, anesthetized patients. Anesthesiology 2000; 93:104-109.
    • (2000) Anesthesiology , vol.93 , pp. 104-109
    • Brimacombe, J.1    Keller, C.2
  • 3
    • 0034930030 scopus 로고    scopus 로고
    • Use of the esophageal doppler with the LMA ProSeal
    • Hemmerling TM. Use of the esophageal doppler with the LMA ProSeal. Anesthesiology 2001; 95:274-275.
    • (2001) Anesthesiology , vol.95 , pp. 274-275
    • Hemmerling, T.M.1
  • 5
    • 0036092075 scopus 로고    scopus 로고
    • Normal oral, rectal, tympanic and axillary body temperature in adult men and women: A systematic literature review
    • Sund L, Forsberg C, Wahren LK. Normal oral, rectal, tympanic and axillary body temperature in adult men and women: a systematic literature review. Scand J Caring Sci 2002; 16:122-128.
    • (2002) Scand J. Caring Sci. , vol.16 , pp. 122-128
    • Sund, L.1    Forsberg, C.2    Wahren, L.K.3
  • 6
    • 0003463685 scopus 로고    scopus 로고
    • Henley-on-Thames: The Laryngeal Mask Company Ltd
    • LMA ProSeal™ Instruction Manual. Henley-on-Thames: The Laryngeal Mask Company Ltd, 2000.
    • (2000) LMA ProSeal™ Instruction Manual
  • 7
    • 0035662708 scopus 로고    scopus 로고
    • Is measurement of body temperature by infrared tympanic thermometry reproducible?
    • Joly LM, Giraudeau B, Monchi M, Oswald AM. Is measurement of body temperature by infrared tympanic thermometry reproducible? Ann Fr Anesth Reanim 2001; 20:833-837.
    • (2001) Ann. Fr. Anesth. Reanim. , vol.20 , pp. 833-837
    • Joly, L.M.1    Giraudeau, B.2    Monchi, M.3    Oswald, A.M.4
  • 8
    • 0025193206 scopus 로고
    • Introduction to biostatistics Part 5: Statistical inference techniques for hypothesis testing with nonparametric data
    • Gaddis GM, Gaddis ML. Introduction to biostatistics Part 5: Statistical inference techniques for hypothesis testing with nonparametric data. Ann Emerg Med 1990; 19:1054-1059.
    • (1990) Ann. Emerg. Med. , vol.19 , pp. 1054-1059
    • Gaddis, G.M.1    Gaddis, M.L.2
  • 9
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999; 8:135-160.
    • (1999) Stat. Methods Med. Res. , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 0035010083 scopus 로고    scopus 로고
    • Gastric insufflation with the ProSeal laryngeal mask
    • Brimacombe J, Keller C, Berry A. Gastric insufflation with the ProSeal laryngeal mask. Anesth Analg 2001; 92:1614-1615.
    • (2001) Anesth. Analg. , vol.92 , pp. 1614-1615
    • Brimacombe, J.1    Keller, C.2    Berry, A.3
  • 11
    • 0027578227 scopus 로고
    • The esophageal temperature gradient in anesthetized children
    • Bloch EC, Ginsberg B, Binner RA. The esophageal temperature gradient in anesthetized children. J Clin Monit 1993; 9:73-77.
    • (1993) J. Clin. Monit. , vol.9 , pp. 73-77
    • Bloch, E.C.1    Ginsberg, B.2    Binner, R.A.3
  • 13
    • 0027650836 scopus 로고
    • Temperature gradient down the oesophagus?
    • Cowling J. Temperature gradient down the oesophagus? Anaesth Intensive Care 199321:476.
    • (1993) Anaesth. Intensive Care , vol.21 , pp. 476
    • Cowling, J.1
  • 14
    • 0036481650 scopus 로고    scopus 로고
    • Comparison of oral and tympanic temperatures in adult surgical patients
    • Gilbert M, Barton AJ, Counsell CM. Comparison of oral and tympanic temperatures in adult surgical patients. Appl Nurs Res 2002; 15:42-47.
    • (2002) Appl. Nurs. Res. , vol.15 , pp. 42-47
    • Gilbert, M.1    Barton, A.J.2    Counsell, C.M.3
  • 15
    • 0003994083 scopus 로고
    • New York: Churchill Livingston
    • Gray's Anatomy. New York: Churchill Livingston, 1989.
    • (1989) Gray's Anatomy


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.