-
1
-
-
0014278076
-
The feasibility of in vivo neutron activation analysis of total body calcium and other elements of body composition
-
Palmer, H. E., Nelp, W. B., Murano, R. and Rich, C. The feasibility of in vivo neutron activation analysis of total body calcium and other elements of body composition. Phys. Med. Biol. 13(2), 269-279 (1968).
-
(1968)
Phys. Med. Biol.
, vol.13
, Issue.2
, pp. 269-279
-
-
Palmer, H.E.1
Nelp, W.B.2
Murano, R.3
Rich, C.4
-
2
-
-
0014911664
-
Use of the cyclotron for whole body neutron activation analysis: Theoretical and practical considerations
-
Chamberlain, M. J., Fremlin, J. H., Holloway, I. and Peters, D. K. Use of the cyclotron for whole body neutron activation analysis: theoretical and practical considerations. Int. J. Appl. Radiat. Isot. 21, 725-734 (1970).
-
(1970)
Int. J. Appl. Radiat. Isot.
, vol.21
, pp. 725-734
-
-
Chamberlain, M.J.1
Fremlin, J.H.2
Holloway, I.3
Peters, D.K.4
-
3
-
-
0014540616
-
Neutron dosimetry in the in vivo measurement of intrathyroidal iodine in man by activation analysis
-
Boddy, K., Dennis, J. A. and Lawson, R. C. Neutron dosimetry in the in vivo measurement of intrathyroidal iodine in man by activation analysis. Phys. Med. Biol. 14(3), 471-480 (1969).
-
(1969)
Phys. Med. Biol.
, vol.14
, Issue.3
, pp. 471-480
-
-
Boddy, K.1
Dennis, J.A.2
Lawson, R.C.3
-
4
-
-
0016592359
-
A high sensitivity dual-detector shadow-shield wholebody counter with an 'invariant' response for total body in vivo neutron activation analysis
-
Boddy, K., Elliott, A., Robertson, I., Mahaffy, M. E. and Holloway, I. A high sensitivity dual-detector shadow-shield wholebody counter with an 'invariant' response for total body in vivo neutron activation analysis. Phys. Med. Biol. 20(2), 296-304 (1975).
-
(1975)
Phys. Med. Biol.
, vol.20
, Issue.2
, pp. 296-304
-
-
Boddy, K.1
Elliott, A.2
Robertson, I.3
Mahaffy, M.E.4
Holloway, I.5
-
5
-
-
0018349139
-
Facility for regional in vivo neutron activation analysis of skeletal calcium
-
Evans, H. J., Leblanc, A. D. and Johnson, P. C. Facility for regional in vivo neutron activation analysis of skeletal calcium. Phys. Med. Biol. 24, 181-187 (1979).
-
(1979)
Phys. Med. Biol.
, vol.24
, pp. 181-187
-
-
Evans, H.J.1
Leblanc, A.D.2
Johnson, P.C.3
-
6
-
-
0019053996
-
The present state of in-vivo neutron activation analysis in clinical diagnosis, and therapy
-
Cohn, S. H. The present state of in-vivo neutron activation analysis in clinical diagnosis, and therapy. At. Energ. Rev. 18(3), 599-660 (1980).
-
(1980)
At. Energ. Rev.
, vol.18
, Issue.3
, pp. 599-660
-
-
Cohn, S.H.1
-
7
-
-
0021213437
-
A prompt gamma in vivo neutron activation analysis facility for measurement of total body nitrogen in the critically ill
-
Beddoe, A. H., Zudmeer, H. and Hill, G. L. A prompt gamma in vivo neutron activation analysis facility for measurement of total body nitrogen in the critically ill. Phys. Med. Biol. 29, 371-383 (1984).
-
(1984)
Phys. Med. Biol.
, vol.29
, pp. 371-383
-
-
Beddoe, A.H.1
Zudmeer, H.2
Hill, G.L.3
-
8
-
-
0024451632
-
Body composition in elderly subjects: A critical appraisal of clinical methodology
-
1167-1175
-
Heymsfield, S. B., Wang, J., Lichtman, S., Kamen, Y., Kehayias. J. and Pierson, R. N. Jr. Body composition in elderly subjects: A critical appraisal of clinical methodology. Am. J. Clin. Nutr. 50(5 Suppl), 1167-1175; 1231-1235 (1989).
-
(1989)
Am. J. Clin. Nutr.
, vol.50
, Issue.5 SUPPL.
, pp. 1231-1235
-
-
Heymsfield, S.B.1
Wang, J.2
Lichtman, S.3
Kamen, Y.4
Kehayias, J.5
Pierson R.N., Jr.6
-
9
-
-
0021637916
-
Techniques of in vivo neutron activation analysis
-
Chettle, D. R. and Fremlin, J. H. Techniques of in vivo neutron activation analysis. Phys. Med. Biol. 29(9), 1011-1043 (1984).
-
(1984)
Phys. Med. Biol.
, vol.29
, Issue.9
, pp. 1011-1043
-
-
Chettle, D.R.1
Fremlin, J.H.2
-
10
-
-
0034116222
-
Human body composition: In vivo methods
-
Ellis, K. J. Human body composition: in vivo methods. Physiol Rev. 80(2), 649-80 (2000).
-
(2000)
Physiol. Rev.
, vol.80
, Issue.2
, pp. 649-680
-
-
Ellis, K.J.1
-
11
-
-
0016892208
-
Neutron yields and energy spectra from thick target Li(p,n) source
-
Ritchie, A. I. M. Neutron yields and energy spectra from thick target Li(p,n) source. J. Phys. D: Appl. Phys. 9, 15-26 (1976).
-
(1976)
J. Phys. D: Appl. Phys.
, vol.9
, pp. 15-26
-
-
Ritchie, A.I.M.1
-
12
-
-
0013240195
-
Determination of the energy scale for neutron cross-section measurements employing a monoenergetic accelerator
-
ANL/TDM-25
-
Meadows, J. W. Determination of the energy scale for neutron cross-section measurements employing a monoenergetic accelerator. ANL/TDM-25 (1977).
-
(1977)
-
-
Meadows, J.W.1
-
14
-
-
0021910831
-
Neutron intensity and energy distributions from protons in the energy range 1.95 MeV to 5.5 MeV incident on thick targets of lithium
-
Clayton, C. G. and Spackman, S. Neutron intensity and energy distributions from protons in the energy range 1.95 MeV to 5.5 MeV incident on thick targets of lithium. Int. J. Appl. Radiat. Isot. 36(1), 13-50 (1985).
-
(1985)
Int. J. Appl. Radiat. Isot.
, vol.36
, Issue.1
, pp. 13-50
-
-
Clayton, C.G.1
Spackman, S.2
-
15
-
-
0026650638
-
Acceleralor-based epithermal neutron beam design for neutron capture therapy
-
Yanch, J. C., Zhou, X. L., Shefer, R. E. and Klinkowstein, R. E. Acceleralor-based epithermal neutron beam design for neutron capture therapy. Med. Phys. 19(3), 709-721 (1992).
-
(1992)
Med. Phys.
, vol.19
, Issue.3
, pp. 709-721
-
-
Yanch, J.C.1
Zhou, X.L.2
Shefer, R.E.3
Klinkowstein, R.E.4
-
16
-
-
0029001902
-
A design study for an accelerator-based epithermal neutron beam fr BNCT
-
Allen, D. A. and Benyon, T. D. A design study for an accelerator-based epithermal neutron beam fr BNCT. Phys. Med. Biol. 40, 807-821 (1995).
-
(1995)
Phys. Med. Biol.
, vol.40
, pp. 807-821
-
-
Allen, D.A.1
Benyon, T.D.2
-
17
-
-
0031251887
-
Analysis of epithermal neutron production by near-threshold (p,n) reactions
-
Zhou, X. L. and Lee, C. Analysis of epithermal neutron production by near-threshold (p,n) reactions. Appl. Radiat. Isot. 48, 1571-1575 (1997).
-
(1997)
Appl. Radiat. Isot.
, vol.48
, pp. 1571-1575
-
-
Zhou, X.L.1
Lee, C.2
-
18
-
-
0031252003
-
Lithium compounds as targets for (p,n) reactions
-
Zhou, X. L. and Lee, C. Lithium compounds as targets for (p,n) reactions. Appl. Radiat. Isot. 48, 1493-1496 (1997).
-
(1997)
Appl. Radiat. Isot.
, vol.48
, pp. 1493-1496
-
-
Zhou, X.L.1
Lee, C.2
-
19
-
-
0031858003
-
10B neutron capture enhancement of fast neutron irradiations
-
10B neutron capture enhancement of fast neutron irradiations. Med. Phys. 25(60), 885-891 (1998).
-
(1998)
Med. Phys.
, vol.25
, Issue.60
, pp. 885-891
-
-
Pignol, J.P.1
Cuendet, P.2
Brassart, N.3
Fares, G.4
Colomb, F.5
M'Bake Diop, C.6
Sabattier, R.7
Hachem, A.8
Prevot, G.9
-
21
-
-
0348047657
-
Accelerator-based neutron source for the neutron-capture and fast neutron therapy at hospital
-
and 14 others
-
Bayanov, B. F. and 14 others. Accelerator-based neutron source for the neutron-capture and fast neutron therapy at hospital. Nucl. Instrum. Methods Phys. Res. A 413(2-3), 397-426 (1998).
-
(1998)
Nucl. Instrum. Methods Phys. Res. A
, vol.413
, Issue.2-3
, pp. 397-426
-
-
Bayanov, B.F.1
-
22
-
-
0032712964
-
Target and filter concepts for accelerator-driven boron neutron capture therapy applications
-
Powell, J. A., Ludewig, H., Todosow, M. and Reich, M. Target and filter concepts for accelerator-driven boron neutron capture therapy applications. Nucl. Tech. 125, 104-115 (1999).
-
(1999)
Nucl. Tech.
, vol.125
, pp. 104-115
-
-
Powell, J.A.1
Ludewig, H.2
Todosow, M.3
Reich, M.4
-
24
-
-
0034670262
-
System design for in-vivo neutron activation analysis measurements of manganese in the human brain: Based on Monte Carlo modeling
-
Arnold, M. L., McNeill F. E., Prestwich, W. V. and Chettle D. R. System design for in-vivo neutron activation analysis measurements of manganese in the human brain: based on Monte Carlo modeling. Appl. Radiat. Isot. 53, 651-656 (2000).
-
(2000)
Appl. Radiat. Isot.
, vol.53
, pp. 651-656
-
-
Arnold, M.L.1
McNeill, F.E.2
Prestwich, W.V.3
Chettle, D.R.4
-
25
-
-
0003949825
-
Development of an accelerator based system for in vivo neutron activation analysis measurements of manganese in humans
-
PhD Thesis, McMaster University, Hamilton, ON, Canada
-
Arnold, M. L. Development of an accelerator based system for in vivo neutron activation analysis measurements of manganese in humans. PhD Thesis, McMaster University, Hamilton, ON, Canada (2000).
-
(2000)
-
-
Arnold, M.L.1
-
26
-
-
0013187504
-
Pilot studies for in-vivo bone aluminum measurements
-
MSc Thesis, McMaster University, Hamilton, ON, Canada
-
Palerme, S. Pilot studies for in-vivo bone aluminum measurements. MSc Thesis, McMaster University, Hamilton, ON, Canada (1993).
-
(1993)
-
-
Palerme, S.1
-
27
-
-
0003967084
-
An accelerator-based in-vivo measurement of aluminum in human bone by neutron activation analysis
-
MSc Thesis, McMaster University, Hamilton, ON, Canada
-
Pejovic-Milic, A. An accelerator-based in-vivo measurement of aluminum in human bone by neutron activation analysis. MSc Thesis, McMaster University, Hamilton, ON, Canada (1998).
-
(1998)
-
-
Pejovic-Milic, A.1
-
28
-
-
4244200026
-
In-vivo measurement of some trace elements in human bone
-
PhD Thesis, McMaster University, Hamilton, ON, Canada
-
Pejovic-Milic, A. In-vivo measurement of some trace elements in human bone. PhD Thesis, McMaster University, Hamilton, ON, Canada (2001).
-
(2001)
-
-
Pejovic-Milic, A.1
-
29
-
-
0032080034
-
Development of an accelerator-based determination of aluminum burden in peripheral bone by neutron activation analysis
-
Pejovic-Milic, A., McNeill, F. E., Prestwitch, W. V., Waker, A. J. and Chettle, D. R. Development of an accelerator-based determination of aluminum burden in peripheral bone by neutron activation analysis. Appl. Radiat. Isot. 49(5/6), 717-719 (1998).
-
(1998)
Appl. Radiat. Isot.
, vol.49
, Issue.5-6
, pp. 717-719
-
-
Pejovic-Milic, A.1
McNeill, F.E.2
Prestwitch, W.V.3
Waker, A.J.4
Chettle, D.R.5
-
30
-
-
0342626747
-
Monte Carlo design study for in-vivo bone aluminum measurement using a low energy accelerator beam
-
Pejovic-Milic, A., Arnold, M. L., McNeill, F. E. and Chettle, D. R. Monte Carlo design study for in-vivo bone aluminum measurement using a low energy accelerator beam. Appl. Radiat. Isot. 53, 657-664 (2000).
-
(2000)
Appl. Radiat. Isot.
, vol.53
, pp. 657-664
-
-
Pejovic-Milic, A.1
Arnold, M.L.2
McNeill, F.E.3
Chettle, D.R.4
-
31
-
-
0033067782
-
The feasibility of measuring manganese concentrations in human liver using neutron activation analysis
-
Arnold, M. L., McNeill, F. E. and Chettle, D. R. The feasibility of measuring manganese concentrations in human liver using neutron activation analysis. NeuroToxicol. 20(2-3), 407-412 (1999).
-
(1999)
NeuroToxicol.
, vol.20
, Issue.2-3
, pp. 407-412
-
-
Arnold, M.L.1
McNeill, F.E.2
Chettle, D.R.3
-
32
-
-
0036852644
-
An accelerator based system for in vivo neutron activation analysis measurements of manganese in human hand bones
-
Arnold, M. L., McNeill, F. E., Stronach, I. M., Waker, A. J., Pejovic-Milic, A. and Chettle D. R. An accelerator based system for in vivo neutron activation analysis measurements of manganese in human hand bones. Med. Phys. 29(11), 2718-2724 (2002).
-
(2002)
Med. Phys.
, vol.29
, Issue.11
, pp. 2718-2724
-
-
Arnold, M.L.1
McNeill, F.E.2
Stronach, I.M.3
Waker, A.J.4
Pejovic-Milic, A.5
Chettle, D.R.6
-
33
-
-
0037814228
-
Spectrometry and dosimetry for low energy accelerator based in-vivo measurements
-
Annual Report McMaster Accelerator Laboratory, McMaster University, Hamilton, ON, Canada
-
Aslam, Prestwich, W. V., McNeill, F. E. and Waker, A. J. Spectrometry and dosimetry for low energy accelerator based in-vivo measurements. Annual Report McMaster Accelerator Laboratory, McMaster University, Hamilton, ON, Canada (2001).
-
(2001)
-
-
Aslam Prestwich, W.V.1
McNeill, F.E.2
Waker, A.J.3
-
34
-
-
0023002057
-
The performance of low pressure tissue-equivalent chambers and a new method for parameterising the dose equivalent
-
Eisen, Y., Brake, R. J., Vasilik, D. G., Erkkila, B. H. and Littlejohn, G. J. The performance of low pressure tissue-equivalent chambers and a new method for parameterising the dose equivalent. Radiat. Prot. Dosim. 15(2), 117-130 (1986).
-
(1986)
Radiat. Prot. Dosim.
, vol.15
, Issue.2
, pp. 117-130
-
-
Eisen, Y.1
Brake, R.J.2
Vasilik, D.G.3
Erkkila, B.H.4
Littlejohn, G.J.5
-
35
-
-
0023816384
-
Intercomparison of dose equivalent meters based on microdosimetric techniques
-
and 10 others
-
Dietze, G. and 10 others. Intercomparison of dose equivalent meters based on microdosimetric techniques. Radiat. Prot. Dosim. 23(1/4), 227-234 (1988).
-
(1988)
Radiat. Prot. Dosim.
, vol.231
, Issue.4
, pp. 227-234
-
-
Dietze, G.1
-
36
-
-
0024803273
-
International intercomparison of TEPC systems used for radiation protection
-
Alberts, W. G., Dietze, E., Guldbakke, S., Kluge, H. and Schuhmacher, H. International intercomparison of TEPC systems used for radiation protection. Radiat. Prot. Dosim. 29, 47-53 (1989).
-
(1989)
Radiat. Prot. Dosim.
, vol.29
, pp. 47-53
-
-
Alberts, W.G.1
Dietze, E.2
Guldbakke, S.3
Kluge, H.4
Schuhmacher, H.5
-
38
-
-
0028273741
-
Performance of TEPCs at low pressures: Some attempts to improve their dose equivalent response in the neutron energy range from 10 keV to 1 MeV
-
Gerdung, S., Grillmaier, R. E., Lim, T., Pihet, P., Schuhmacher, H. and Ségur, P. Performance of TEPCs at low pressures: some attempts to improve their dose equivalent response in the neutron energy range from 10 keV to 1 MeV. Radiat. Prot. Dosim. 52(1-4), 57-59 (1994).
-
(1994)
Radiat. Prot. Dosim.
, vol.52
, Issue.1-4
, pp. 57-59
-
-
Gerdung, S.1
Grillmaier, R.E.2
Lim, T.3
Pihet, P.4
Schuhmacher, H.5
Ségur, P.6
-
39
-
-
0029621943
-
Principles of experimental microdosimetry
-
Waker, A. J. Principles of experimental microdosimetry. Radiat. Prot. Dosim. 61(4), 297-308 (1995).
-
(1995)
Radiat. Prot. Dosim.
, vol.61
, Issue.4
, pp. 297-308
-
-
Waker, A.J.1
-
40
-
-
0028969892
-
An evaluation of hydrogen as a TEPC counting gas in radiation protection microdosimetry
-
Khaloo, R. and Waker, A. J. An evaluation of hydrogen as a TEPC counting gas in radiation protection microdosimetry. Radiat. Prot. Dosim. 58(3), 185-191 (1995).
-
(1995)
Radiat. Prot. Dosim.
, vol.58
, Issue.3
, pp. 185-191
-
-
Khaloo, R.1
Waker, A.J.2
-
41
-
-
0028879741
-
An analytical correction for the TEPC dose equivalent response problem
-
Taylor, G. C. An analytical correction for the TEPC dose equivalent response problem. Radiat. Prot. Dosim. 61(1-3), 67-70 (1995).
-
(1995)
Radiat. Prot. Dosim.
, vol.61
, Issue.1-3
, pp. 67-70
-
-
Taylor, G.C.1
-
42
-
-
0036024636
-
Measurement of lineal-energy distributions for neutrons of 8 keV to 65 MeV by using a tissue-equivalent proportional counter
-
Nunomiya, T., Kim, E., Kurosawa, T., Taniguchi, S., Yonai, S., Nakamura, T., Nakane, Y., Sakamoto, Y. and Tanaka, S. Measurement of lineal-energy distributions for neutrons of 8 keV to 65 MeV by using a tissue-equivalent proportional counter. Radiat. Prot. Dosim. 102(1), 49-59 (2002).
-
(2002)
Radiat. Prot. Dosim.
, vol.102
, Issue.1
, pp. 49-59
-
-
Nunomiya, T.1
Kim, E.2
Kurosawa, T.3
Taniguchi, S.4
Yonai, S.5
Nakamura, T.6
Nakane, Y.7
Sakamoto, Y.8
Tanaka, S.9
-
43
-
-
77956698352
-
Recommendations of the ICRP
-
ICRP. ICRP Publication (Oxford: Pergamon Press)
-
ICRP. Recommendations of the ICRP. Ann. ICRP 1(3). ICRP Publication 26 (Oxford: Pergamon Press) (1977).
-
(1977)
Ann. ICRP
, vol.1
, Issue.3
, pp. 26
-
-
-
44
-
-
0003534769
-
Radiation protection recommendation of the International Commission on Radiological Protection
-
ICRP. ICRP Publication (Oxford: Pergamon Press)
-
ICRP. Radiation protection recommendation of the International Commission on Radiological Protection. ICRP Publication 60 (Oxford: Pergamon Press) (1991).
-
(1991)
, pp. 60
-
-
-
45
-
-
0003524676
-
The quality factor in radiation protection
-
ICRU. (Bethesda, MD: ICRU Publications)
-
ICRU. The quality factor in radiation protection. ICRU Report 40 (Bethesda, MD: ICRU Publications) (1986).
-
(1986)
ICRU Report
, pp. 40
-
-
-
46
-
-
0038151963
-
204Tl
-
PhD Thesis, McMaster University, Hamilton, ON, Canada
-
204Tl. PhD Thesis, McMaster University, Hamilton, ON, Canada (1982).
-
(1982)
-
-
Cousins, T.1
-
47
-
-
0029773860
-
Microdosimetry of monoenergelic neutrons
-
Srdoc, D. and Marino, S. A. Microdosimetry of monoenergelic neutrons. Radiat. Res. 146(4), 466-474 (1996).
-
(1996)
Radiat. Res.
, vol.146
, Issue.4
, pp. 466-474
-
-
Srdoc, D.1
Marino, S.A.2
-
48
-
-
0003697463
-
Stopping powers and ranges for protons and alpha particles
-
ICRU. (Bethesda, MD: ICRU Publications)
-
ICRU. Stopping powers and ranges for protons and alpha particles. ICRU Report 49 (Bethesda, MD: ICRU Publications) (1983).
-
(1983)
ICRU Report
, pp. 49
-
-
-
49
-
-
0038490469
-
Microdosimetry
-
ICRU. (Bethesda, MD: ICRU Publications)
-
ICRU. Microdosimetry. ICRU Report 36 (Bethesda, MD: ICRU Publications) (1983).
-
(1983)
ICRU Report
, pp. 36
-
-
-
51
-
-
0023756258
-
TEPC radiation protection dosimetry in the environment of accelerators and at nuclear facilities
-
Folkerts, K. H., Menzel, H. G., Schuhmacher H. and Arend, E. TEPC radiation protection dosimetry in the environment of accelerators and at nuclear facilities. Radiat. Prot. Dosim. 23(1-4), 261-264 (1988).
-
(1988)
Radiat. Prot. Dosim.
, vol.23
, Issue.1-4
, pp. 261-264
-
-
Folkerts, K.H.1
Menzel, H.G.2
Schuhmacher, H.3
Arend, E.4
-
52
-
-
0021723118
-
Optimization of the design of microdosimetric dose equivalent meters
-
Kawecka, B., Morstin, K. and Booz, J. Optimization of the design of microdosimetric dose equivalent meters. Radiat. Prot. Dosim. 9(3), 203-206 (1984).
-
(1984)
Radiat. Prot. Dosim.
, vol.9
, Issue.3
, pp. 203-206
-
-
Kawecka, B.1
Morstin, K.2
Booz, J.3
-
53
-
-
0032003371
-
Use of photodiode in microdosimetry and evaluation of effective quality factor
-
Kadachi, A., Waheed, A., Al-Eshaikh, M. and Obeid, M. Use of photodiode in microdosimetry and evaluation of effective quality factor. Nucl. Instrum. Methods Res. A 404(2-3), 400-406 (1998).
-
(1998)
Nucl. Instrum. Methods Res. A
, vol.404
, Issue.2-3
, pp. 400-406
-
-
Kadachi, A.1
Waheed, A.2
Al-Eshaikh, M.3
Obeid, M.4
-
54
-
-
0014917281
-
Dose equivalent meter designs based on tissue equivalent proportional counters
-
Baum, J., Kuehner, V. and Chase, R. Dose equivalent meter designs based on tissue equivalent proportional counters. Health Phys. 19, 813-824 (1970).
-
(1970)
Health Phys.
, vol.19
, pp. 813-824
-
-
Baum, J.1
Kuehner, V.2
Chase, R.3
-
55
-
-
0020658176
-
Neutron quality parameters versus energy below 4 MeV from microdosimetric calculations
-
Stinchcomb, T. G. and Borak, T. B. Neutron quality parameters versus energy below 4 MeV from microdosimetric calculations. Radiat. Res. 93(1), 1-18 (1983).
-
(1983)
Radiat. Res.
, vol.93
, Issue.1
, pp. 1-18
-
-
Stinchcomb, T.G.1
Borak, T.B.2
-
56
-
-
0023442394
-
Simple parameterization for quality factors as a function of linear energy transfer
-
Townsend, W., Wilson, J. and Cucinotta, F. Simple parameterization for quality factors as a function of linear energy transfer. Health Phys. 53(5), 531-532 (1987).
-
(1987)
Health Phys.
, vol.53
, Issue.5
, pp. 531-532
-
-
Townsend, W.1
Wilson, J.2
Cucinotta, F.3
-
57
-
-
0003815030
-
The atomic nucleus
-
(New York: McGraw-Hill)
-
Evans, R. D. The atomic nucleus (New York: McGraw-Hill) (1955).
-
(1955)
-
-
Evans, R.D.1
-
58
-
-
0029314329
-
Neutron generator at Hiroshima university for use in radiobiology study
-
and 12 others
-
Endo, S. and 12 others. Neutron generator at Hiroshima university for use in radiobiology study. J. Radiat. Res. (Tokyo) 36(2), 91-102 (1995).
-
(1995)
J. Radiat. Res. (Tokyo)
, vol.36
, Issue.2
, pp. 91-102
-
-
Endo, S.1
-
59
-
-
0033287459
-
Neutron generator (HIRRAC) and dosimetry study
-
Endo, S., Hoshi, M., Takada, J., Tauchi, H., Matsuura, S., Takeoka, S., Kitagawa, K., Suga, S. and Komatsu, K. Neutron generator (HIRRAC) and dosimetry study. J. Radiat. Res. (Tokyo) 40(Suppl.) 14-20 (1999).
-
(1999)
J. Radiat. Res. (Tokyo)
, vol.40
, Issue.SUPPL.
, pp. 14-20
-
-
Endo, S.1
Hoshi, M.2
Takada, J.3
Tauchi, H.4
Matsuura, S.5
Takeoka, S.6
Kitagawa, K.7
Suga, S.8
Komatsu, K.9
-
61
-
-
0003942186
-
Introduction to radiological physics and radiation dosimetry
-
(New York: Wiley)
-
Attix, F. H. Introduction to radiological physics and radiation dosimetry. (New York: Wiley) (1986).
-
(1986)
-
-
Attix, F.H.1
-
62
-
-
0004161838
-
-
2nd edn, FORTRAN numerical recipes (Cambridge University Press)
-
Press. W. H., Teukolsky, S. A., Vetterling, W. T. and Flannery, B. P. Numerical recipes in FORTRAN 77: the art of scientific computing. 2nd edn, Vol. 1. In: FORTRAN numerical recipes (Cambridge University Press) (1992).
-
(1992)
Numerical Recipes in FORTRAN 77: The Art of Scientific Computing
, vol.1
-
-
Press, W.H.1
Teukolsky, S.A.2
Vetterling, W.T.3
Flannery, B.P.4
-
63
-
-
0000918072
-
Unified conversion functions for the ICRU operational radiation protection quantities
-
Wagner, S. R., Grosswendt, B., Harvey, J. R., Mill, A. J., Selbach, H. J. and Siebert, B. R. L. Unified conversion functions for the ICRU operational radiation protection quantities. Radiat. Prot. Dosim. 12(2), 231-235 (1985).
-
(1985)
Radiat. Prot. Dosim.
, vol.12
, Issue.2
, pp. 231-235
-
-
Wagner, S.R.1
Grosswendt, B.2
Harvey, J.R.3
Mill, A.J.4
Selbach, H.J.5
Siebert, B.R.L.6
-
64
-
-
0028150752
-
Photon and neutron dose contributions and mean quality factors phantoms of diffirent size irradiated by monoenergetic neutrons
-
Dietze, G. and Siebert, B. R. Photon and neutron dose contributions and mean quality factors phantoms of diffirent size irradiated by monoenergetic neutrons. Radiat. Res. 140(1), 130-133 (1994).
-
(1994)
Radiat. Res.
, vol.140
, Issue.1
, pp. 130-133
-
-
Dietze, G.1
Siebert, B.R.2
|