메뉴 건너뛰기




Volumn 42, Issue 2, 2003, Pages 169-176

Model driven therapy: The instance of computer assisted medical interventions

Author keywords

Medical imaging; Medical robotics; Surgical navigation; Virtual university

Indexed keywords

ACCURACY; COMPUTER ASSISTED THERAPY; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER MODEL; COMPUTER PROGRAM; CONFERENCE PAPER; DECISION MAKING; ECHOGRAPHY; MEDICAL INFORMATION; MEDICAL RESEARCH; NUCLEAR MAGNETIC RESONANCE IMAGING; PHYSICIAN; PRIORITY JOURNAL; SAFETY; SURGEON; TREATMENT PLANNING; X RAY ANALYSIS;

EID: 0038106197     PISSN: 00261270     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-0038-1634329     Document Type: Conference Paper
Times cited : (3)

References (16)
  • 1
    • 0038523545 scopus 로고    scopus 로고
    • MI3 http://mi3.vitamib.com/
  • 2
    • 0037509643 scopus 로고    scopus 로고
    • Interpolation of lacking data in tomography
    • IEEE (ISBN 0-7803-9813-0)
    • Desbat L. Interpolation of lacking data in tomography. In SampTA 2001. IEEE (ISBN 0-7803-9813-0), 2001:123-8.
    • (2001) SampTA , pp. 123-128
    • Desbat, L.1
  • 3
    • 84947745831 scopus 로고    scopus 로고
    • Building a complete surface model from sparse data using statistical shape models: Application to computer assisted knee surgery
    • Wells WM, Colchester A, Delp S, eds. Springer Verlag
    • Fleute M., Lavallee S. Building a Complete Surface Model from Sparse Data Using Statistical Shape Models: Application to Computer Assisted Knee Surgery. In: Wells WM, Colchester A, Delp S, eds. Medical Image Computing and Computer-Assisted Intervention-MICCAI'98: Springer Verlag, 1998:880-7.
    • (1998) Medical Image Computing and Computer-Assisted Intervention-MICCAI'98 , pp. 880-887
    • Fleute, M.1    Lavallee, S.2
  • 4
    • 0033182766 scopus 로고    scopus 로고
    • Incorporating a statistically based shape model into a system for computer-assisted anterior cruciate ligament surgery
    • Fleute M. Incorporating a statistically based shape model into a system for computer-assisted anterior cruciate ligament surgery. Medical Image Analysis 1999, 3 (3):209-22.
    • (1999) Medical Image Analysis , vol.3 , Issue.3 , pp. 209-222
    • Fleute, M.1
  • 5
    • 0034070906 scopus 로고    scopus 로고
    • The Mesh-Matching algorithm: An automatic 3D mesh generator for finite element structures
    • Couteau B., Payan Y., Lavallée S. The Mesh-Matching algorithm: an automatic 3D mesh generator for finite element structures. Journal of Biomechanics, vol. 33/8:1005-9.
    • Journal of Biomechanics , vol.33 , Issue.8 , pp. 1005-1009
    • Couteau, B.1    Payan, Y.2    Lavallée, S.3
  • 6
    • 84878171770 scopus 로고    scopus 로고
    • A 3D Finite Element model of the face for simulation in plastic and maxillo-facial surgery
    • Springer Verlag, LNCS
    • Chabanas M., Payan Y. A 3D Finite Element model of the face for simulation in plastic and maxillo-facial surgery. In Medical Image Computing and Computer-Assisted Intervention - MICCAI'2000: Springer Verlag, volume 1935 of LNCS, 2000:1068-75.
    • (2000) Medical Image Computing and Computer-Assisted Intervention - MICCAI'2000 , vol.1935 , pp. 1068-1075
    • Chabanas, M.1    Payan, Y.2
  • 7
    • 0035222473 scopus 로고    scopus 로고
    • A methodological tool for computer-assisted surgery interface design: Its application to computer-assisted pericardial puncture
    • Westwood JD ed, IOS Press
    • Dubois E., Nigay L., Troccaz J., Carrat L., Chavanon O. A methodological tool for computer-assisted surgery interface design: its application to computer-assisted pericardial puncture. In Westwood JD ed, Medecine Meets Virtual Reality: IOS Press, 2001:136-9.
    • (2001) Medecine Meets Virtual Reality , pp. 136-139
    • Dubois, E.1    Nigay, L.2    Troccaz, J.3    Carrat, L.4    Chavanon, O.5
  • 9
    • 0032081409 scopus 로고    scopus 로고
    • Guiding systems for Computer-assisted Surgery (CAS): Introducing synergistic devices and discussing the different approaches
    • Troccaz J., Peshkin M., Davies B. Guiding systems for Computer-assisted Surgery (CAS): introducing synergistic devices and discussing the different approaches. Medical Image Analysis, 2(2), 1998:101-19.
    • (1998) Medical Image Analysis , vol.2 , Issue.2 , pp. 101-119
    • Troccaz, J.1    Peshkin, M.2    Davies, B.3
  • 10
    • 0038184938 scopus 로고    scopus 로고
    • IGOS http://www-sante.ujf-grenoble.fr/SANTE/IGOS/Final.htm
  • 14
    • 84947745831 scopus 로고    scopus 로고
    • Building a complete surface model from sparse data using statistical shape models: Application to computer assisted knee surgery
    • Wells WM, Colchester A, Delp S, eds. Springer Verlag
    • Fleute M., Lavallee S. Building a Complete Surface Model from Sparse Data Using Statistical Shape Models: Application to Computer Assisted Knee Surgery. In: Wells WM, Colchester A, Delp S, eds. Medical Image Computing and Computer-Assisted Intervention-MICCAI'98: Springer Verlag, 1998:880-7.
    • (1998) Medical Image Computing and Computer-Assisted Intervention-MICCAI'98 , pp. 880-887
    • Fleute, M.1    Lavallee, S.2
  • 16
    • 0038184942 scopus 로고    scopus 로고
    • VOEU http://voeu.vitamib.com/


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.