Volumn 43, Issue 1-4 SPEC, 2003, Pages 159-165

Lessons learned with vibration monitoring systems in German nuclear power plants

Author keywords

Automated monitoring system; Boiling water reactor (BWR); Condition monitoring system; Correlation analyses; Fuel assembly vibration; Internal vibrations; Model calculations; Neutron noise investigation; Pressurized water reactor (PWR); Vibration monitoring

Indexed keywords

CALCULATIONS; CONDITION MONITORING; CORRELATION METHODS; INSTALLATION; MATHEMATICAL MODELS; PRESSURIZED WATER REACTORS; PUMPS; VIBRATIONS (MECHANICAL);

EID: 0038078233     PISSN: 01491970     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0149-1970(03)00022-2     Document Type: Article
Times cited : (6)

References (5)
  • 3
    • 31444448866 scopus 로고    scopus 로고
    • Diagnostische Überwachung von Zwangsumwälzpumpen an Siedewasserreaktoren deutscher Kernkraftwerke
    • Stabel N., Kolbasseff A. and Ußkilat B. (1999), Diagnostische Überwachung von Zwangsumwälzpumpen an Siedewasserreaktoren deutscher Kernkraftwerke, VDI-Schwingungstagung, Mannheim
    • (1999) VDI-Schwingungstagung, Mannheim
    • Stabel, N.1    Kolbasseff, A.2    Ußkilat, B.3