메뉴 건너뛰기




Volumn 2, Issue ASIA PACIFIC, 2002, Pages 1411-1415

Design of XLPE cables and soundness confirmation methods to extra high voltage XLPE cables

Author keywords

Cable design; Completion test; Degradation; Diagnosis; Electric stress; Partial discharge; Water tree; XLPE cable

Indexed keywords

DEGRADATION; ELECTRIC INSULATION; ELECTRIC LINES; ELECTRIC POTENTIAL; PARTIAL DISCHARGES; SIGNAL PROCESSING; STRESSES;

EID: 0037970464     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (9)

References (12)
  • 1
    • 0030129308 scopus 로고    scopus 로고
    • Development of 500-kV XLPE cables and accessories for long distance underground transmission lines
    • Apr.
    • M. Fukawa, T. Kawai, Y. Okano, S. Sakuma, S. Asai, M. Kanaoka, H. Yamanouchi, "Development of 500-kV XLPE Cables and Accessories for Long Distance Underground Transmission Lines," IEEE Trans. Power Delivery, vol.11, pp.627-634, Apr. 1996.
    • (1996) IEEE Trans. Power Delivery , vol.11 , pp. 627-634
    • Fukawa, M.1    Kawai, T.2    Okano, Y.3    Sakuma, S.4    Asai, S.5    Kanaoka, M.6    Yamanouchi, H.7
  • 2
    • 0038056297 scopus 로고
    • Endurance tests with polyethylene insulated cables
    • F.H. Kreuger, "Endurance tests with polyethylene insulated cables," CIGAE No. 21-02, 1968.
    • (1968) CIGAE No.21-02 , vol.21 , Issue.2
    • Kreuger, F.H.1
  • 3
    • 0642318089 scopus 로고
    • The use of thermoplastic insulating material in the manufacture of extra high voltage cables for DC and AC
    • J.M. Oudin, Ch.A. Flamand, "The use of thermoplastic insulating material in the manufacture of extra high voltage cables for DC and AC," CIGRE, No.209, 1962.
    • (1962) CIGRE, No.209 , vol.209
    • Oudin, J.M.1    Flamand, Ch.A.2
  • 7
    • 0038732726 scopus 로고    scopus 로고
    • Partial-discharge automatic-monitoring system for extra-high voltage XLPE cable lines
    • Aug.
    • H. Eshima, H. Suzuki, T. Endoh, K. Takahashi, M. Fukasawa, "Partial-Discharge Automatic-Monitoring System for Extra-High Voltage XLPE Cable Lines," Hitachi Cable Review, No. 16, pp.9-18, Aug. 1997.
    • (1997) Hitachi Cable Review , Issue.16 , pp. 9-18
    • Eshima, H.1    Suzuki, H.2    Endoh, T.3    Takahashi, K.4    Fukasawa, M.5
  • 10
    • 0038394672 scopus 로고    scopus 로고
    • Insulating properties of field aged 66 kV XLPE cable after long-term high freqency accelerated aging test installed in water
    • Mar. [in Japanese]
    • T. Tanaka, A. Tanaka, K. Okuyama, Y. Murata, S. Katakai, "Insulating Properties of Field Aged 66 kV XLPE Cable after Long-term High Freqency Accelerated Aging Test Installed in Water," National Convention of IEEJ, No.299, Mar. 1999 [in Japanese].
    • (1999) National Convention of IEEJ , vol.299
    • Tanaka, T.1    Tanaka, A.2    Okuyama, K.3    Murata, Y.4    Katakai, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.