메뉴 건너뛰기




Volumn 18, Issue 3 SUPPL. 1, 2003, Pages 104-106

Onlay cortical strut grafting in revision arthroplasty of the hip

Author keywords

Allograft; Cortical strut; Femoral defects; Revision hip

Indexed keywords

ALLOGRAFT; BONE GRAFT; BONE RADIOGRAPHY; CIRCUMFERENTIAL WIRE; CONFERENCE PAPER; DIAPHYSIS; FEMUR MALFORMATION; FIBULA; FOLLOW UP; GUIDE WIRE; HIP ARTHROPLASTY; HUMAN; JOINT STABILITY; MAJOR CLINICAL STUDY; ONLAY CORTICAL STRUT GRAFTING; OSTEOLYSIS; PROSTHESIS FAILURE; PSEUDARTHROSIS; REOPERATION; SURGICAL ANATOMY; SURGICAL APPROACH; SURGICAL TECHNIQUE;

EID: 0037967328     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1054/arth.2003.50077     Document Type: Conference Paper
Times cited : (18)

References (7)
  • 1
    • 0030794798 scopus 로고    scopus 로고
    • The role of allografts in the treatment of periprosthetic femoral fractures
    • Chandler HP, Tigges RG, Russel G: The role of allografts in the treatment of periprosthetic femoral fractures. J Bone Joint Surg Am 79:1422, 1997
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 1422
    • Chandler, H.P.1    Tigges, R.G.2    Russel, G.3
  • 2
    • 0026467234 scopus 로고
    • Cortical strut allografts in the reconstruction of the femur in revision total hip arthroplasty: A basic science and clinical study
    • Emerson RH, Malinin TI, Cuellar AD, et al: Cortical strut allografts in the reconstruction of the femur in revision total hip arthroplasty: a basic science and clinical study. Clin Orthop 285:35, 1992
    • (1992) Clin Orthop , vol.285 , pp. 35
    • Emerson, R.H.1    Malinin, T.I.2    Cuellar, A.D.3
  • 3
    • 0036600202 scopus 로고    scopus 로고
    • Periprosthetic femoral fractures around well-fixed implants: Use of cortical onlay allografts with or without a plate
    • Haddad FS, Duncan CP, Berry DJ, et al: Periprosthetic femoral fractures around well-fixed implants: use of cortical onlay allografts with or without a plate. J Bone Joint Surg Am 84:945, 2002
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 945
    • Haddad, F.S.1    Duncan, C.P.2    Berry, D.J.3
  • 4
    • 0035715620 scopus 로고    scopus 로고
    • Cortical strut allograft in revision total hip arthroplasty
    • Wong PKC, King A, Hutchison CR, Gross AE: Cortical strut allograft in revision total hip arthroplasty. Hip Int 4:186, 2001
    • (2001) Hip Int , vol.4 , pp. 186
    • Wong, P.K.C.1    King, A.2    Hutchison, C.R.3    Gross, A.E.4
  • 5
    • 0029151690 scopus 로고
    • Management of structurally deficient femur in revision total hip replacement
    • Head WC, Emerson RHJ, Hillyard JM, Higgins LL: Management of structurally deficient femur in revision total hip replacement. Orthopedics 18:865, 1995
    • (1995) Orthopedics , vol.18 , pp. 865
    • Head, W.C.1    Emerson, R.H.J.2    Hillyard, J.M.3    Higgins, L.L.4
  • 6
    • 0027427408 scopus 로고
    • Femoral strut allografts in cementless revision total hip arthroplasty
    • Pak JH, Paprosky WG, Jablonsky WS, Lawrence JM: Femoral strut allografts in cementless revision total hip arthroplasty. Clin Orthop 295:172, 1993
    • (1993) Clin Orthop , vol.295 , pp. 172
    • Pak, J.H.1    Paprosky, W.G.2    Jablonsky, W.S.3    Lawrence, J.M.4
  • 7
    • 0029694033 scopus 로고    scopus 로고
    • Freeze-dried cortical strut allografts for femoral reconstruction in revision hip replacement surgery
    • Pirtchard DJ (ed). American Academy of Orthopaedic Surgeons
    • Head WC, Emerson RH, Malinin TI: Freeze-dried cortical strut allografts for femoral reconstruction in revision hip replacement surgery. p. 131. In Pirtchard DJ (ed): AAOS Instructional Course Lectures. American Academy of Orthopaedic Surgeons, 1996
    • (1996) AAOS Instructional Course Lectures , pp. 131
    • Head, W.C.1    Emerson, R.H.2    Malinin, T.I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.