메뉴 건너뛰기




Volumn 15, Issue 10 II, 2002, Pages 1154-1159

Comprehensive assessment of patent ductus arteriosus by echocardiography before transcatheter closure

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOGRAPHY; AORTA; ARTICLE; CHILD; DISEASE CLASSIFICATION; FEMALE; HEART CATHETERIZATION; HUMAN; INFANT; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; PATENT DUCTUS ARTERIOSUS; RETROSPECTIVE STUDY; TWO DIMENSIONAL ECHOCARDIOGRAPHY; AGE; CHILD WELFARE; COMPARATIVE STUDY; ECHOCARDIOGRAPHY; OBSERVER VARIATION; PEROPERATIVE CARE; PRESCHOOL CHILD; STATISTICS; TREATMENT OUTCOME; UNITED STATES;

EID: 0037964123     PISSN: 08947317     EISSN: None     Source Type: Journal    
DOI: 10.1067/mje.2002.124573     Document Type: Article
Times cited : (16)

References (18)
  • 1
    • 0026551445 scopus 로고
    • Percutaneous closure of small (<2.5 mm) patent ductus arteriosus using coil embolization
    • Cambier PA, Kirby WC, Worthman DC, Moore JW. Percutaneous closure of small (<2.5 mm) patent ductus arteriosus using coil embolization. Am J Cardiol 1992;69:815-6.
    • (1992) Am J Cardiol , vol.69 , pp. 815-816
    • Cambier, P.A.1    Kirby, W.C.2    Worthman, D.C.3    Moore, J.W.4
  • 2
    • 0027301293 scopus 로고
    • Transcatheter occlusion of patent ductus arteriosus with adjustable buttoned device: Initial clinical experience
    • Rao PS, Sideris EB, Haddad J. Transcatheter occlusion of patent ductus arteriosus with adjustable buttoned device: initial clinical experience. Circulation 1993;88:1119-26.
    • (1993) Circulation , vol.88 , pp. 1119-1126
    • Rao, P.S.1    Sideris, E.B.2    Haddad, J.3
  • 3
    • 0028092055 scopus 로고
    • Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils
    • Hijazi ZM, Geggel RL. Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils. Am J Cardiol 1994;74:925-9.
    • (1994) Am J Cardiol , vol.74 , pp. 925-929
    • Hijazi, Z.M.1    Geggel, R.L.2
  • 6
    • 0031539325 scopus 로고    scopus 로고
    • Evaluation of Gianturco coils for closure of large (3.5 mm) patent ductus arteriosus
    • Owada CY, Teitel DF, Moore P. Evaluation of Gianturco coils for closure of large (3.5 mm) patent ductus arteriosus. J Am Coll Cardiol 1997;30:1856-62.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1856-1862
    • Owada, C.Y.1    Teitel, D.F.2    Moore, P.3
  • 7
    • 0031811253 scopus 로고    scopus 로고
    • Comparison of cost and clinical outcome between transcatheter coil occlusion and surgical closure of isolated patent ductus arteriosus
    • Prieto LR, DeCamillo DM, Konrad DJ, Scalet-Longworth L, Latson LA. Comparison of cost and clinical outcome between transcatheter coil occlusion and surgical closure of isolated patent ductus arteriosus. Pediatrics 1998;101:1020-4.
    • (1998) Pediatrics , vol.101 , pp. 1020-1024
    • Prieto, L.R.1    DeCamillo, D.M.2    Konrad, D.J.3    Scalet-Longworth, L.4    Latson, L.A.5
  • 8
    • 0033133414 scopus 로고    scopus 로고
    • The snare-assisted technique for transcatheter coil occlusion of moderate to large patent ductus arteriosus: Immediate and long-term results
    • Ing FI, Sommer RJ. The snare-assisted technique for transcatheter coil occlusion of moderate to large patent ductus arteriosus: immediate and long-term results. J Am Coll Cardiol 1999;33:1710-8.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 1710-1718
    • Ing, F.I.1    Sommer, R.J.2
  • 9
    • 0035173218 scopus 로고    scopus 로고
    • Transcatheter closure of persistent arterial ducts with different types of coils
    • Cheung Y, Leung MP, Chau K. Transcatheter closure of persistent arterial ducts with different types of coils. Am Heart J 2001;41:87-91.
    • (2001) Am Heart J , vol.41 , pp. 87-91
    • Cheung, Y.1    Leung, M.P.2    Chau, K.3
  • 10
    • 0034653717 scopus 로고    scopus 로고
    • Further experience with transcatheter closure of the patent ductus arteriosus using the Amplatzer duct occluder
    • Thanopoulos, BD, Hakim FA, Hiari A, Goussos Y, Basta E, Zarayelyan AA, et al. Further experience with transcatheter closure of the patent ductus arteriosus using the Amplatzer duct occluder. J Am Coll Cardiol 2000;35:1016-21.
    • (2000) J Am Coll Cardiol , vol.35 , pp. 1016-1021
    • Thanopoulos, B.D.1    Hakim, F.A.2    Hiari, A.3    Goussos, Y.4    Basta, E.5    Zarayelyan, A.A.6
  • 11
    • 0035179725 scopus 로고    scopus 로고
    • Comparison of two transcatheter closure methods of persistently patent arterial duct
    • Justino H, Justo RN, Ovaert C, Magee A, Lee K-J, Hashmi A, et al. Comparison of two transcatheter closure methods of persistently patent arterial duct. Am J Cardiol 2001;87:76-81.
    • (2001) Am J Cardiol , vol.87 , pp. 76-81
    • Justino, H.1    Justo, R.N.2    Ovaert, C.3    Magee, A.4    Lee, K.-J.5    Hashmi, A.6
  • 14
    • 0024558526 scopus 로고
    • Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion
    • Krichenko A, Benson LN, Burrows P, Moes CAF. Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion. Am J Cardiol 1989;63:877-80.
    • (1989) Am J Cardiol , vol.63 , pp. 877-880
    • Krichenko, A.1    Benson, L.N.2    Burrows, P.3    Moes, C.A.F.4
  • 15
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 16
    • 0018095773 scopus 로고
    • Real-time cross-sectional echocardiographic imaging and measurement of the patent ductus arteriosus in infants and children
    • Sahn DJ, Allen HD. Real-time cross-sectional echocardiographic imaging and measurement of the patent ductus arteriosus in infants and children. Ciruclation 1978;58:343-58.
    • (1978) Ciruclation , vol.58 , pp. 343-358
    • Sahn, D.J.1    Allen, H.D.2
  • 17
    • 0031760680 scopus 로고    scopus 로고
    • Validation of color Doppler measurements of minimum patent ductus arteriosus diameters: Significance for coil embolization
    • Wong JA, Shim D, Khoury PR, Meyer RA. Validation of color Doppler measurements of minimum patent ductus arteriosus diameters: significance for coil embolization. Am Heart J 1998;136:714-7.
    • (1998) Am Heart J , vol.136 , pp. 714-717
    • Wong, J.A.1    Shim, D.2    Khoury, P.R.3    Meyer, R.A.4
  • 18
    • 0023937916 scopus 로고
    • Color Doppler flow mapping in patients with coarctation of the aorta: New observations and improved evaluation with color flow diameter and proximal acceleration as predictors of severity
    • Simpson IA, Sahn DJ, Valdez-Cruz LM, Chung KJ, Sherman FS, Swenssson RE. Color Doppler flow mapping in patients with coarctation of the aorta: new observations and improved evaluation with color flow diameter and proximal acceleration as predictors of severity. Circulation 1988;77:736-44.
    • (1988) Circulation , vol.77 , pp. 736-744
    • Simpson, I.A.1    Sahn, D.J.2    Valdez-Cruz, L.M.3    Chung, K.J.4    Sherman, F.S.5    Swenssson, R.E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.