Volumn 13, Issue 4, 2003, Pages 724-728

Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner

Author keywords

Artifacts; Attenuation correction; CT; PET

Indexed keywords

ARTICLE; ARTIFACT; CANCER PATIENT; CLINICAL ARTICLE; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DATA ANALYSIS; DEVICE; DIAGNOSTIC ACCURACY; HUMAN; IMAGE ANALYSIS; INFORMATION PROCESSING; POSITRON EMISSION TOMOGRAPHY; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RADIATION ATTENUATION; TOOTH IMPLANTATION;

EID: 0037936886     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-002-1564-2     Document Type: Article
Times cited : (142)

References (13)
  • 1
    • 0030865170 scopus 로고    scopus 로고
    • Whole-body positron emission tomography in clinical oncology: Comparison between attenuation-corrected and uncorrected images
    • Bengel FM, Ziegler SI, Avril N, Weber W, Laubenbacher C, Schwaiger M (1997) Whole-body positron emission tomography in clinical oncology: comparison between attenuation-corrected and uncorrected images. Eur J Nucl Med 24:1091-1098
    • (1997) Eur. J. Nucl. Med. , vol.24 , pp. 1091-1098
    • Bengel, F.M.1    Ziegler, S.I.2    Avril, N.3    Weber, W.4    Laubenbacher, C.5    Schwaiger, M.6
  • 2
    • 0034926067 scopus 로고    scopus 로고
    • Evaluation of head and neck cancer with 18F-FDG PET: A comparison with conventional methods
    • Kresnik E, Mikosch P, Gallowitsch HJ et al. (2001) Evaluation of head and neck cancer with 18F-FDG PET: a comparison with conventional methods. Eur J Nucl Med 28:816-821
    • (2001) Eur. J. Nucl. Med. , vol.28 , pp. 816-821
    • Kresnik, E.1    Mikosch, P.2    Gallowitsch, H.J.3
  • 3
    • 0033933908 scopus 로고    scopus 로고
    • Cost considerations regarding an integrated CT-PET system
    • Von Schulthess GK (2000) Cost considerations regarding an integrated CT-PET system. Eur Radiol 10:S377-S380
    • (2000) Eur. Radiol. , vol.10
    • Von Schulthess, G.K.1
  • 4
    • 0031791001 scopus 로고    scopus 로고
    • Attenuation correction for a combined 3D PET/CT scanner
    • Kinahan PE, Townsend DW, Beyer T, Sashin D (1998) Attenuation correction for a combined 3D PET/CT scanner. Med Phys 25:2046-2053
    • (1998) Med. Phys. , vol.25 , pp. 2046-2053
    • Kinahan, P.E.1    Townsend, D.W.2    Beyer, T.3    Sashin, D.4
  • 5
    • 0023224718 scopus 로고
    • Reduction of CT artifacts caused by metallic implants
    • Kalender WA, Hebel R, Ebersberger J (1987) Reduction of CT artifacts caused by metallic implants. Radiology 164:576-577
    • (1987) Radiology , vol.164 , pp. 576-577
    • Kalender, W.A.1    Hebel, R.2    Ebersberger, J.3
  • 7
    • 0011954972 scopus 로고    scopus 로고
    • An automatic classification technique for attenuation correction in positron emission tomography
    • Bettinardi V, Pagani E, Gilardi MC et al. (1999) An automatic classification technique for attenuation correction in positron emission tomography. Eur J Nucl Med 26:447-458
    • (1999) Eur. J. Nucl. Med. , vol.26 , pp. 447-458
    • Bettinardi, V.1    Pagani, E.2    Gilardi, M.C.3
  • 8
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8:307-310
    • (1986) Lancet , vol.8 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 9
    • 0018853278 scopus 로고
    • Blackout and other artefacts in computed tomography caused by fillings in teeth
    • Svendsen P, Quiding L, Landahl I (1980) Blackout and other artefacts in computed tomography caused by fillings in teeth. Neuroradiology 19:229-234
    • (1980) Neuroradiology , vol.19 , pp. 229-234
    • Svendsen, P.1    Quiding, L.2    Landahl, I.3
  • 11
    • 0027998049 scopus 로고
    • Cranio-orbital reconstruction: Safety and image quality of metallic implants on CT and MRI scanning
    • Sullivan PK, Smith JF, Rozzelle AA (1994) Cranio-orbital reconstruction: safety and image quality of metallic implants on CT and MRI scanning. Plast Reconstr Surg 94:589-596
    • (1994) Plast. Reconstr. Surg. , vol.94 , pp. 589-596
    • Sullivan, P.K.1    Smith, J.F.2    Rozzelle, A.A.3
  • 12
    • 33747599964 scopus 로고    scopus 로고
    • Attenuation-correction induced artifact in F-18 FDG PET imaging following total knee replacement
    • Heiba SI, Luo J, Sadek S et al. (2000) Attenuation-correction induced artifact in F-18 FDG PET imaging following total knee replacement. Clin Positron Imaging 3:237-239
    • (2000) Clin. Positron Imaging , vol.3 , pp. 237-239
    • Heiba, S.I.1    Luo, J.2    Sadek, S.3
  • 13
    • 0038669533 scopus 로고    scopus 로고
    • Influence of attenuation correction (AC) in positron emission tomography (PET) and combined PET-CT on artifacts of hip protheses
    • Goerres GW, Burger CN, Berthold T, Buck A (2001) Influence of attenuation correction (AC) in positron emission tomography (PET) and combined PET-CT on artifacts of hip protheses. Radiology (Suppl) 221:386
    • (2001) Radiology , vol.221 , Issue.SUPPL. , pp. 386
    • Goerres, G.W.1    Burger, C.N.2    Berthold, T.3    Buck, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.